Monolisa™ 26154
Monolisa 26154 is a hepatitis B virus surface total antibody IVD (FDA Class II; FDA product code LOM, Test, Hepatitis B (B Core, Be Antigen, Be Antibody, B Core Igm)) made by Bio-Rad Laboratories, approved under FDA PMA P050048 on 25 Aug 2006 and listed in FDA GUDID since 22 Aug 2014 (UDI-DI 00847865002097), active as of 23 Oct 2026. 3 FDA recalls are linked to it.
Active
Valid until
No expiry
FDA recalls
None ongoingDocuments
Trust
Regulatory status
| Region | Authorization | Number | Date | Status |
|---|---|---|---|---|
| United States | GUDID listing | Number00847865002097 | Date22 Aug 2014 | StatusListed |
| United States | FDA PMAAPRL | NumberP050048 | Date25 Aug 2006 | StatusActive |
Official records
- AccessGUDID record 00847865002097
- FDA PMA database P050048
From the FDA record
- Device description
- Anti-HBs EIA, 10 mIU/mL Calibrator 1.8 mL
- MRI safety
- Labeling does not contain MRI Safety Information
- Natural rubber latex
- No latex statement on the label
- Sterility
- Supplied non-sterile
Across registries
- FDA PMA P050048 decided 25 Aug 2006 Active
- FDA GUDID UDI-DI 00847865002097 listed 22 Aug 2014 Listed
Recalls
-
- Terminated Z-1840-2015
The spare component Anti-HBs Cutoff Calibrator, Catalog number 26154, is recalled because the expiration date of 2016-04-30 printed on label in error.
-
- Terminated Z-2398-2012
Prolonged exposure of the MONOLISA Anti-HBs EIA Conjugate Diluent component to light may result in elevated Optical Densities (OD) in some samples such that a negative sample could elevate to a grey zone or low positive result.
-
- Terminated Z-1620-2010
The package insert provided with this kit contains a typographical error, giving incorrect directions to prepare a Working Conjugate Solution. If these directions are followed, it would result in a 1:6 dilution and invalidate the assay.
Timeline
- Approved FDA PMA P050048
- Recall initiated FDA recalls Z-1620-2010
- Recall initiated FDA recalls Z-2398-2012
- Listed FDA GUDID 00847865002097
- Recall initiated FDA recalls Z-1840-2015
Coverage
- Active
- Expiring
- Withdrawn
- Listed
- Not covered
United States — FDA PMA Active
Specification
- Trade name
- Monolisa™
- Generic name
- Hepatitis B virus surface total antibody IVD, calibrator
- Model / Ref / Catalog
- 26154
- Primary DI / UDI-DI
- 00847865002097
- PMA number
- FDA product code
- LOM
- GMDN term
- Hepatitis B virus surface total antibody IVD, calibrator
- Device class
- Class II
- Regulation number
- 866.3172
- GUDID distribution status
- In Commercial Distribution
- Size
- Total Volume — 1.8 Milliliter
Similar devices
Other devices filed under FDA product code LOM (Test, Hepatitis B (B Core, Be Antigen, Be Antibody, B Core Igm)).
- Atellica™ IM HBsII QC 10995605 by Siemens Healthcare Diagnostics Inc.
- Atellica™ IM HBsII 10995604 by Siemens Healthcare Diagnostics Inc.
- IMMULITE 2000 HBsAg Confirmatory by SIEMENS HEALTHCARE DIAGNOSTICS PRODUCTS LTD
- ARCHITECT HBsAg Next Qualitative/Next Confirmatory by Abbott Laboratories
- AXSYM HBSAG by Abbott Laboratories, Inc.
- LIAISON Murex HBsAg Qual by Diasorin Inc.
- Elecsys HBsAg Test System by Roche Diagnostics Corp.
- Abbott HBE Diagnostic Kit by Abbott Laboratories
- LIAISON XL MUREX HBsAg Qual; LIAISON XL MUREX Control HBsAg Qual; LIAISON XL MUREX HBsAg Confirmatory by Diasorin Inc.
- AxSYM Core 2.0 (LN 8B88) by Abbott Laboratories, Inc.