Skip to content

Thornhill Research Inc.

by Thornhill Research Inc

Ref 127406

Thornhill Research Inc. (127406) is a transport electric ventilator (EU MDD Class IIa; FDA Class II; FDA product code BTL, Ventilator, Emergency, Powered (Resuscitator)) made by Thornhill Research Inc, registered in EUDAMED on 23 Feb 2026 (Basic UDI-DI B-10807141000084), cleared under FDA 510(k) K093261 on 26 Mar 2010 and listed in FDA GUDID since 1 Oct 2020 (UDI-DI 10807141000084), active as of 22 Oct 2026. 2 FDA recalls are linked to it.

Active European Union and United States. Also listed in GUDID (US).

CE MDD 510(k)

Valid until

No date given

CE: no date in EUDAMED. FDA: not time-limited

FDA recalls

None ongoing

2 closed

Documents

None linked in EUDAMED

A group certificate may exist

510(k) K093261

FDA submission, from GUDID

Trust

Unverified

Source EUDAMED, GUDID, synced 22 Oct 2026.

Regulatory status

as of registry sync 22 Oct 2026

RegionAuthorizationNumberDateStatus
European UnionCE/MDD EUDAMED NumberB-10807141000084 Basic UDI-DI 10807141000084UDI-DIDate23 Feb 2026RegisteredStatusActive
United StatesGUDID listing GUDID Number10807141000084 UDI-DI Date1 Oct 2020ListedStatusListed GUDID: in commercial distribution
United StatesFDA 510(k)SESE GUDID from GUDID Substantially Equivalent · Traditional NumberK093261 Date26 Mar 2010DecidedStatusActive

Official records

From the FDA record

Device description
Hose, 0.04" x 0.0625", Nafion w/ Label
MRI safety
Labeling does not contain MRI Safety Information
Natural rubber latex
No latex statement on the label
Sterility
Supplied non-sterile

From the GUDID record (AccessGUDID), as read on 30 May 2026, as the labeller entered it.

Across registries

3 registries list this device

  • EUDAMED Basic UDI-DI B-10807141000084 registered 23 Feb 2026 Active
  • FDA 510(k) K093261 decided 26 Mar 2010 Active
  • FDA GUDID UDI-DI 10807141000084 listed 1 Oct 2020 Listed

Recalls

2 recalls · FDA

  • 2 recalls, same reason

    • Terminated Z-0586-2016 FDA Class I initiated 19 Nov 2015
    • Terminated Z-0587-2016 FDA Class I initiated 19 Nov 2015

    Batteries found unresponsive after storage, not recognized by main device, and are perpetually enabled.

Timeline

5 dated events

  1. Cleared FDA 510(k) K093261
  2. Recall initiated FDA recalls Z-0586-2016
  3. Recall initiated FDA recalls Z-0587-2016
  4. Listed FDA GUDID 10807141000084
  5. Registered EUDAMED B-10807141000084

Coverage

2 jurisdictions

United States of AmericaSwedenFinlandLatviaEstoniaDenmarkLithuaniaIrelandNetherlandsGermanyPolandFranceBelgiumLuxembourgCzech RepublicSlovakiaAustriaHungaryRomaniaSloveniaBulgariaPortugalSpainItalyCroatiaGreeceMaltaCyprus
  • Active
  • Expiring
  • Withdrawn
  • Listed
  • Not covered
  • European Union CE/MDD Active
  • United States FDA 510(k) Active

Specification

EUDAMED · GUDID

Trade name
Thornhill Research Inc. EUDAMED
Moves GUDID
Generic name
Transport electric ventilator
Device name
MOVES® SLC™ Nafion Tube [Kit, MOVES SLC, Nafion Tube]
Model / reference
127406 EUDAMED
124241 GUDID
Primary DI / UDI-DI
10807141000084
Basic UDI-DI
B-10807141000084
510(k) Number
FDA product code
BTL
EMDN code
R020108 Respiratory gas monitoring and sampling circuits and kits
GMDN term
Transport electric ventilator
Device class
Class IIa EUDAMED
Class II GUDID
Regulation number
868.5925
EU registration type
Legacy device (under a directive)
EU market of registration
Netherlands
GUDID distribution status
In Commercial Distribution

Truth per registry

2 sources · 2 fields differ

FieldEUDAMEDGUDID
Model / referenceEUDAMED
127406
GUDID
124241
Device classEUDAMED
Class IIa
GUDID
Class II

Device class is stated on each registry's own scale: Class IIa in the EU (EUDAMED), Class II in the US (FDA GUDID). EU and US classes are different schemes, so this is not a disagreement.

Manufacturer details

EUDAMED SRN
CA-MF-000039470
Authorised representative
Freyr Regulatory GmbH DE-AR-000047121

Similar devices in this category

Other devices filed under RESPIRATORY GAS MONITORING AND SAMPLING CIRCUITS AND KITS.

Other devices from Thornhill Research Inc

See all devices from Thornhill Research Inc →

Properties

  • Prescription use
  • Lot / batch number
Other properties (21, all answered No)