Skip to content

MP Reconstruction Prosthesis 172-930/20

by WALDEMAR LINK GmbH & Co. KG EUDAMEDGUDID

Active European Union and United States

Ref 172-930/20Model Hip stem, uncemented, Ti6Al4V, ribbed

Regulatory status

as of 28 Oct 2026

Recall ongoing. 1 ongoing FDA recall. See recalls

RegionAuthorizationNumberDateStatus
European UnionCE/MDR EUDAMED Number4026575-1-HSR-050001-Y3 Basic UDI-DIDate27 May 2026RegisteredStatusActive
United StatesGUDID listing GUDID Number04026575202997 UDI-DIDate1 Nov 2015ListedStatusIn distribution

Coverage

2 jurisdictions

United States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaSwedenFinlandFinlandSwedenFinlandFinlandSwedenSwedenLatviaEstoniaDenmarkLithuaniaIrelandNetherlandsGermanyGermanyPolandPolandFranceBelgiumLuxembourgCzech RepublicSlovakiaPolandFranceFranceAustriaHungaryRomaniaFranceFranceSloveniaBulgariaPortugalSpainSpainItalySpainSpainCroatiaGreeceMaltaCyprus
  • Active
  • Expiring
  • Withdrawn
  • Listed
  • Not known
  • Not covered
  • European Union CE/MDR Active
  • United States GUDID listing Listed

Certificates

1 certificate · EUDAMED

EUDAMED certificates (1)
  • 13792GB450240723 Issued

    Technical documentation EU MDR

    Notified body
    Notified body 0482
    Issued
    23 Jul 2024
    Expires
    22 Jul 2029

Recalls

2 recalls · 1 ongoing · FDA

    • Ongoing Z-0769-2025 FDA Class II initiated 5 Dec 2024

    Error on the main label and the patient label. The labels indicate a size XXL, this is a standard-size neck segment.. All further information on the labels is correct (Length, CCD and Offset).

    • Terminated Z-0733-2019 FDA Class II initiated 7 Dec 2018

    The reaming guide and the guide rod can't be screwed into the intended depth. The reason for this is a reduced depth of the core hole in the stem. A reaming guide that is not screwed in completely may lead to a proximal preparation in the depth that is not sufficient and to a neck that can't be positioned correctly. The correct fit of the neck can't be verified by means of the guide rod.

Specification

EUDAMED · GUDID

Trade Name
MP Reconstruction Prosthesis
Generic Name
Press-fit hip femur prosthesis, modular
Device Name
MP Reconstruction System
Model / Ref / Catalog
172-930/20, Hip stem, uncemented, Ti6Al4V, ribbed
Primary DI / UDI-DI
04026575202997
Basic UDI-DI
4026575-1-HSR-050001-Y3
510(k) Number
FDA Product Code
LZO, LWJ, JDI
EMDN Code
P090804010206 Uncemented femoral stems for primary implant, with modular neck, straight
GMDN Term
Press-fit hip femur prosthesis, modular
Device Class
Class III EUDAMED
Class II GUDID
Regulation Number
888.3353, 888.3360, 888.3350
Market of Registration
Germany
Commercial Distribution
In Commercial Distribution

Truth per registry

2 sources · 1 field differs

FieldEUDAMEDGUDID
Device ClassEUDAMED
Class III
GUDID
Class II

Other devices from WALDEMAR LINK GmbH & Co. KG

See all devices from WALDEMAR LINK GmbH & Co. KG →

Properties

  • Sterile
  • Single Use
  • Implantable
  • Prescription Use
  • Lot / Batch Number
  • Expiration Date

Other properties (18)

  • Reusable: No
  • Contains Latex: No
  • Reprocessed: No
  • CMR Substance: No
  • Human-derived: No
  • Human Tissues: No
  • Animal Tissues: No
  • Endocrine Disruptor: No
  • Administering Medicine: No
  • Measuring Function: No
  • Incorporates Medicinal Product: No
  • Over-the-Counter: No
  • Convenience Kit: No
  • Combination Product: No
  • HCT/P: No
  • Premarket Exempt: No
  • Serial Number: No
  • Manufacturing Date: No