IntelliVue Patient Monitors MP2, X2, MP5, MP20, MP30, MP40, MP50, MP60, MP70, MP80, and MP90
by Philips Medizinsysteme Boeblingen GmbH, Cardiac AN
510(k) K071426
Active
Valid until
No expiry
FDA recalls
None foundDocuments
Trust
Unverified
Regulatory status
| Region | Authorization | Number | Date | Status |
|---|---|---|---|---|
| United States | FDA 510(k)SESE | NumberK071426 | Date13 Jun 2007 | StatusActive |
Recalls
No FDA recalls found in the data synced 22 Oct 2026.
Coverage
- Active
- Expiring
- Withdrawn
- Listed
- Not covered
United States — FDA 510(k) Active
Specification
- Full name
- MP2, X2, MP5, MP20, MP30, MP40, MP50, MP60, MP70, MP80, and MP90 Intellivue Patient Monitors
- 510(k) Number
- FDA Product Code
- MHX
- Device Class
- Class II
- Regulation
- 21 CFR Part 870.1025
- Advisory Committee
- Cardiovascular
- FDA Decision
- SESE Substantially Equivalent
Overview
AI-generated summary, 19 Sep 2026
The IntelliVue Patient Monitors are physiological patient monitors with arrhythmia detection and alarms, designed for continuous monitoring of patient vital signs in clinical settings. The MP2, X2, MP5, MP20, MP30, MP40, and MP50 models are additionally intended for use in transport situations within hospital environments, while the MP5 is also intended for use during patient transport outside of a hospital environment.
These monitors are supplied by Philips Medizinsysteme Boeblingen GmbH and are regulated under FDA 510(k) clearance with product code MHX and regulation number 870.1025. The devices are classified as Class II and are listed under multiple registration and FEI numbers. Software versions referenced include release H.0 with software H.0x.xx, and configuration applies to models including MP5SC, MP5T, and the X2 Multi-Measurement Module when used as a standalone monitor.
Other devices from Philips Medizinsysteme Boeblingen GmbH, Cardiac AN
See all devices from Philips Medizinsysteme Boeblingen GmbH, Cardiac AN →
Questions
AI-generated answers, 19 Sep 2026
What clinical purposes do these IntelliVue patient monitors serve?
These monitors are designed for continuous physiological monitoring of patients in clinical settings, with specific functionality for arrhythmia detection and alarms. The MP2, X2, MP5, MP20, MP30, MP40, and MP50 models are additionally intended for use during patient transport within hospital environments, while the MP5 model is also cleared for transport outside of hospital settings.
How are the monitors supplied and who is the manufacturer?
The monitors are supplied by Philips Medizinsysteme Boeblingen GmbH, located in Boeblingen, Germany. The company is listed as the applicant and manufacturer for this device family, with the specific address at Hewlett-Packard St. 2, D 71034.
Are these monitors single-use or reusable, and what is their sterilization status?
The device data does not specify whether these monitors are single-use or reusable, nor does it provide information about sterilization methods. As physiological monitoring systems intended for continuous use in clinical settings, they are typically reusable medical devices, but the exact reprocessing instructions would need to be confirmed from the manufacturer's labeling.
What models are included in this monitor family and are there different capabilities?
The family includes MP2, X2, MP5, MP20, MP30, MP40, MP50, MP60, MP70, MP80, and MP90 models. The MP2 through MP50 models are intended for transport use within hospitals, with the MP5 also cleared for external hospital transport. Configuration variants mentioned include MP5SC, MP5T, and the X2 Multi-Measurement Module when used as a standalone monitor. Software version H.0 with software H.0x.xx applies across these configurations.
What regulatory pathway was used for clearance and how should this be documented?
These monitors were cleared through the FDA 510(k) premarket notification pathway under product code MHX and regulation number 870.1025. The clearance was granted as a Special type with a Substantially Equivalent decision, reviewed by the Cardiovascular advisory committee. The specific 510(k) number is K071426, with a decision date of June 13, 2007. The devices are classified as Class II and have multiple registration and FEI numbers on file.