Mr 7700
by Philips Medical Systems Nederland B.V. Netherlands EUDAMEDGUDID
Ref 782120
Product code LNHEMDN Z11050105
Regulatory status
Recall ongoing. 45 ongoing FDA recalls. See recalls
| Region | Authorization | Number | Date | Status |
|---|---|---|---|---|
| European Union | CE/MDR EUDAMED | Number2243595CE01 | Date24 Sep 2026 | StatusActive |
| United States | GUDID listing GUDID | Number00884838104112 | Date8 Apr 2022 | StatusIn distribution |
Coverage
- Active
- Listed
- Not covered
- European Union
- United States
Certificates
- 2243595CE01 Supplemented
Quality management system EU MDR
- Notified body
- Notified body 0344
- Issued
- 24 Sep 2026
- Expires
- 1 May 2030
- Reason
- Add device or group
Recalls
-
- Ongoing Z-3311-2026
- Ongoing Z-3316-2026
- Ongoing Z-3313-2026
When exporting diffusion tensor imaging (DTI) scans from a MR system using the Enhanced MR DICOM format, the exports contain incorrect data (diffusion directions). If the Enhanced MR DICOM export is used in conjunction with third-party software for tractography (e.g. for mapping nerve fiber pathways in the brain), the software will not be able to correctly process the DTI data for reconstruction.
-
- Ongoing Z-3243-2026
- Ongoing Z-3239-2026
- Ongoing Z-3242-2026
A software issue will terminate an examination during the image reconstruction process if the scan parameters are manually adjusted such that reconstruction requirements exceed the available system memory.
-
- Ongoing Z-1969-2026
- Ongoing Z-1963-2026
The potential for stiffness value errors when a specific range of image reconstruction parameters is used in combination with Resoundant's algorithm, leading to the reconstruction voxel size settings in the default MRE scan protocol displaying too small.
-
- Ongoing Z-1213-2026
- Ongoing Z-1214-2026
The potential for stiffness value errors when viewing exported MR Elastography (MRE) stiffness maps to viewer Picture Archiving and Communication System (PACS).
-
- Ongoing Z-2207-2025
- Ongoing Z-2214-2025
The potential for component failures in the Gradient Coil of the affected MR systems may act as a heat source with a potential to produce smoke and/or fire.
-
- Ongoing Z-1805-2025
- Ongoing Z-1792-2025
Potential for alignment errors in the cross reference line functionality when reviewing images generated with the MobiView application.
-
- Ongoing Z-1782-2025
- Ongoing Z-1776-2025
- Ongoing Z-1783-2025
- Ongoing Z-1772-2025
- Ongoing Z-1770-2025
- Ongoing Z-0951-2024
The Quadrature Body Coil (QBC) seal adhesive may fail, creating sharp edges that may come in contact with patients. If the QBC seal becomes loose during the scanning process, the risk to the patient may include skin abrasions, bruises, lacerations, hair loss/entanglement, and tissue injury.
-
- Ongoing Z-3201-2024
- Ongoing Z-3193-2024
- Ongoing Z-3198-2024
- Ongoing Z-3199-2024
- Ongoing Z-3205-2024
- Ongoing Z-3202-2024
- Ongoing Z-3196-2024
- Ongoing Z-3200-2024
- Ongoing Z-3203-2024
- Ongoing Z-3194-2024
- Ongoing Z-3204-2024
- Ongoing Z-3195-2024
- Ongoing Z-3197-2024
Integrated Radio Frequency (IRF) Carrier assembly screws may come loose and protrude beyond the surface could cause the screws to interfere with other moving parts, potentially blocking the horizontal tabletop. May lead to delay in diagnosis and/or may include anxiety of a patient is left on the tabletop inside the bore for a longer duration than anticipated. movement.
-
- Ongoing Z-1570-2024
- Ongoing Z-1571-2024
- Ongoing Z-1588-2024
Patient support table floor plate may be incorrectly installed.
-
- Ongoing Z-2395-2023
- Ongoing Z-2396-2023
The system operator is able to bypass the SmokeDetector Interlock system locking mechanism after a smoke detection by power cycling the system.
-
- Ongoing Z-2399-2023
- Ongoing Z-2398-2023
During installation of the SmokeDetector Interlock, a connecting cable, between the SmokeDetector Interlock and the host PC, may not have been properly installed. This connection is used for service diagnostics and does not impact the functionality of the system and/or the SmokeDetector Interlock system.
-
- Ongoing Z-0463-2023
- Ongoing Z-0461-2023
- Ongoing Z-0462-2023
- Ongoing Z-0459-2023
- Ongoing Z-0460-2023
Gradient Coil may act as a heat source with a potential to produce smoke and/or fire.
Specification
- Trade Name
- Mr 7700 EUDAMEDMR 7000 Series GUDID
- Generic Name
- Full-body MRI system, superconducting magnet
- Device Name
- Magnetic Resonance Imaging Systems
- Model / Ref / Catalog
- 782120, MR 7700
- Primary DI / UDI-DI
- 00884838104112
- Basic UDI-DI
- 0884838BM697TZ
- Direct Marketing DI
- 00884838104112
- FDA Product Code
- LNH, LNI
- EMDN Code
- Z11050105 Closed magnet MRI scanners with magnetic field greater than 2t and less than or equal to 4t
- GMDN Term
- Full-body MRI system, superconducting magnet
- Device Class
- Class IIb EUDAMEDClass II GUDID
- Regulation Number
- 892.1000
- Market of Registration
- Netherlands
- Commercial Distribution
- In Commercial Distribution
Truth per registry
| Field | EUDAMED | GUDID |
|---|---|---|
| Model / Reference | 782120 | MR 7700 |
| Device Class | Class IIb | Class II |
Manufacturer details
- EUDAMED SRN
- NL-MF-000001489
Other devices from Philips Medical Systems Nederland B.V.
See all devices from Philips Medical Systems Nederland B.V. →
Properties & raw data
Show properties, registry sources and raw records
Other properties (22)
- Sterile: No
- Single Use: No
- Implantable: No
- Reusable: No
- Contains Latex: No
- Reprocessed: No
- CMR Substance: No
- Human-derived: No
- Human Tissues: No
- Animal Tissues: No
- Endocrine Disruptor: No
- Administering Medicine: No
- Measuring Function: No
- Incorporates Medicinal Product: No
- Over-the-Counter: No
- Convenience Kit: No
- Combination Product: No
- HCT/P: No
- Premarket Exempt: No
- Lot / Batch Number: No
- Expiration Date: No
- Manufacturing Date: No