Skip to content

Multi-drive Interference Screw INTF-40-10P

by Nvision Biomedical Technologies, Inc

Multi-drive Interference Screw INTF-40-10P is a tendon/ligament bone anchor (FDA Class II; FDA product code MBI, Fastener, Fixation, Nondegradable, Soft Tissue) made by Nvision Biomedical Technologies, Inc, cleared under FDA 510(k) K200428 on 10 Nov 2020 and listed in FDA GUDID since 7 May 2025 (UDI-DI 00810135962155), active as of 22 Oct 2026.

Active United States. Also listed in GUDID (US).

510(k)

Valid until

No expiry

510(k) clearance is not time-limited

FDA recalls

None found

in data synced 22 Oct 2026

Documents

510(k) K200428

FDA submission, from GUDID

Trust

Unverified

Source GUDID, synced 22 Oct 2026.

Regulatory status

as of registry sync 22 Oct 2026

RegionAuthorizationNumberDateStatus
United StatesGUDID listing Number00810135962155 UDI-DI Date7 May 2025ListedStatusListed GUDID: in commercial distribution
United StatesFDA 510(k)SESE from GUDID Substantially Equivalent · Traditional NumberK200428 Date10 Nov 2020DecidedStatusActive

Official records

From the FDA record

Device description
4.0mm Dia X 10mm Long PEEK Interference Screw. The Multi-Drive Interference Screw System is intended for soft tissue reattachment, i.e. fixation of ligament and tendon graft tissue and tendon transfers in surgeries of the shoulder, elbow, knee, foot/ankle, and hand /wrist. Specifically: Shoulder: Rotator Cuff Repairs, Bankart Repair, SLAP Lesion Repair, Biceps Tenodesis, Acromio-Clavicular Separation Repair, Deltoid Repair, Capsular Shift or Capsulolabral Reconstruction Foot/Ankle: Lateral Stabilization, Medial Stabilization, Achilles Tendon Repair, Hallux Valgus Reconstruction, Midfoot Reconstruction, Metatarsal Ligament Repair, Flexor Hallucis Longus Transfer for Achilles Tendon Reconstruction, and Flexor Digitorum Longus Transfer for Posterior Tibial Tendon Reconstruction Knee: Anterior Cruciate Ligament Repair, Medial Collateral Ligament Repair, Lateral Collateral Ligament Repair, Patellar Tendon Repair, Posterior Oblique Ligament Repair, Iliotibial Band Tenodesis Elbow: Biceps Tendon Reattachment, Ulnar or Radial Collateral Ligament Reconstruction Hand/Wrist: Scapholunate Ligament Reconstruction, Ulnar Collateral Ligament Reconstruction, Radial Collateral Ligament Reconstruction, Carpometacarpal joint arthroplasty (basal thumb joint arthroplasty), Carpal Ligament Reconstructions and repairs. Ligament Reconstruction and Tendon Interposition
MRI safety
MR Safe
Natural rubber latex
Labelled as not made with natural rubber latex
Sterility
Supplied non-sterile; sterilise before use (Moist Heat or Steam Sterilization)

From the GUDID record (AccessGUDID), as read on 22 Oct 2026, as the labeller entered it.

Across registries

2 registries list this device

  • FDA 510(k) K200428 decided 10 Nov 2020 Active
  • FDA GUDID UDI-DI 00810135962155 listed 7 May 2025 Listed

Timeline

2 dated events

  1. Cleared FDA 510(k) K200428
  2. Listed FDA GUDID 00810135962155

Coverage

1 jurisdiction

United States of America
  • Active
  • Expiring
  • Withdrawn
  • Listed
  • Not covered

United States — FDA 510(k) Active

Specification

GUDID

Trade name
Multi-drive Interference Screw
Generic name
Tendon/ligament bone anchor, non-bioabsorbable
Model / reference
INTF-40-10P
Primary DI / UDI-DI
00810135962155
510(k) Number
FDA product code
MBI
GMDN term
Tendon/ligament bone anchor, non-bioabsorbable
Device class
Class II
Regulation number
888.3040
GUDID distribution status
In Commercial Distribution
Sterilisation method
Moist Heat or Steam Sterilization
MRI safety
MR Safe
Size
Outer Diameter — 4.0 Millimeter
Length — 10 Millimeter

Similar devices in this category

Other devices filed under Tendon/ligament bone anchor, non-bioabsorbable.

Other devices from Nvision Biomedical Technologies, Inc

See all devices from Nvision Biomedical Technologies, Inc →

Properties

  • Sterilise before use
  • Single use
  • Implantable
  • Prescription use
  • Lot / batch number
Other properties (10, all answered No)