Skip to content

MULTIGEN Knee Patellar Vice

by Limacorporate

Ref 9066.40.020Model MULTIGEN Plus - Patellar Vice, 80333901R013EV

MULTIGEN Knee Patellar Vice (9066.40.020) is an orthopaedic inorganic implant inserter/extractor (EU MDR Class I; FDA Class II) made by Limacorporate, registered in EUDAMED on 6 Nov 2026 (Basic UDI-DI B-08033390046077), cleared under FDA 510(k) K141934 on 2 Apr 2015 and listed in FDA GUDID since 27 Jul 2016 (UDI-DI 08033390046077), active as of 7 Nov 2026.

Active European Union and United States. Also listed in GUDID (US).

CE MDR CE MDD 510(k)

Valid until

No date given

CE: no date in EUDAMED. FDA: not time-limited

FDA recalls

None found

in data synced 7 Nov 2026

Documents

None linked in EUDAMED

A group certificate may exist

510(k) K141934

FDA submission, from GUDID

Trust

Unverified

Source EUDAMED, GUDID, synced 7 Nov 2026.

Regulatory status

as of registry sync 7 Nov 2026

RegionAuthorizationNumberDateStatus
European UnionCE/MDR EUDAMED NumberB-08033390046077 Basic UDI-DI 08033390046077UDI-DIDate6 Nov 2026RegisteredStatusActive
European UnionCE/MDD EUDAMED NumberB-08033390046077 Basic UDI-DI 08033390046077UDI-DIDate6 Nov 2026RegisteredStatusActive
United StatesGUDID listing GUDID Number08033390046077 UDI-DI Date27 Jul 2016ListedStatusListed GUDID: in commercial distribution
United StatesFDA 510(k)SESE GUDID from GUDID Substantially Equivalent · Traditional NumberK141934 Date2 Apr 2015DecidedStatusActive

Official records

From the FDA record

Device description
Patellar Vice
MRI safety
Labeling does not contain MRI Safety Information
Natural rubber latex
No latex statement on the label
Sterility
Supplied non-sterile; sterilise before use (Moist Heat or Steam Sterilization)

From the GUDID record (AccessGUDID), as read on 7 Nov 2026, as the labeller entered it.

Across registries

3 registries list this device

  • EUDAMED Basic UDI-DI B-08033390046077 registered 6 Nov 2026 Active· +1 more in the status table
  • FDA 510(k) K141934 decided 2 Apr 2015 Active
  • FDA GUDID UDI-DI 08033390046077 listed 27 Jul 2016 Listed

Timeline

3 dated events

  1. Cleared FDA 510(k) K141934
  2. Listed FDA GUDID 08033390046077
  3. Registered EUDAMED B-08033390046077

Coverage

2 jurisdictions

United States of AmericaSwedenFinlandLatviaEstoniaDenmarkLithuaniaIrelandNetherlandsGermanyPolandFranceBelgiumLuxembourgCzech RepublicSlovakiaAustriaHungaryRomaniaSloveniaBulgariaPortugalSpainItalyCroatiaGreeceMaltaCyprus
  • Active
  • Expiring
  • Withdrawn
  • Listed
  • Not covered
  • European Union CE/MDR, CE/MDD Active
  • United States FDA 510(k) Active

Specification

EUDAMED · GUDID

Trade name
MULTIGEN Plus - Patellar Vice EUDAMED
MULTIGEN Knee GUDID
Generic name
Orthopaedic inorganic implant inserter/extractor, reusable
Model / Ref / Catalog
MULTIGEN Plus - Patellar Vice, 9066.40.020, 80333901R013EV, Patellar Vice
Primary DI / UDI-DI
08033390046077
Basic UDI-DI
B-08033390046077, 80333901R013EV
510(k) Number
FDA product code
HRY, JWH
EMDN code
L091199, L091103
GMDN term
Orthopaedic inorganic implant inserter/extractor, reusable
Device class
Class I EUDAMED
Class II GUDID
Regulation number
888.3530, 888.3560
EU registration type
Legacy device (under a directive)
Standard device
EU market of registration
Italy
GUDID distribution status
In Commercial Distribution
Sterilisation method
Moist Heat or Steam Sterilization

Truth per registry

2 sources · 2 fields differ

FieldEUDAMEDGUDID
Model / referenceEUDAMED
MULTIGEN Plus - Patellar Vice
9066.40.020
80333901R013EV
GUDID
Patellar Vice
Device classEUDAMED
Class I
GUDID
Class II

Device class is stated on each registry's own scale: Class I in the EU (EUDAMED), Class II in the US (FDA GUDID). EU and US classes are different schemes, so this is not a disagreement.

Similar devices in this category

Other devices filed under ORTHOPAEDIC PROSTHESES FORCEPS, REUSABLE.

Other devices from Limacorporate

See all devices from Limacorporate →

Properties

  • Sterilise before use
  • Reusable
  • Prescription use
  • Lot / batch number
Other properties (21, all answered No)