181-03-03
181-03-03 is an orthopaedic inorganic implant inserter/extractor (FDA Class II; FDA product code KWZ, Prosthesis, hip, constrained, cemented or uncemented, metal/polymer) made by Exactech, Inc., cleared under FDA 510(k) K071676 on 19 Jul 2007 and listed in FDA GUDID since 19 Mar 2026 (UDI-DI 10885862661470), active as of 23 Oct 2026. 2 FDA recalls are linked to it.
Active
Valid until
No expiry
FDA recalls
2 ongoingDocuments
Trust
Regulatory status
| Region | Authorization | Number | Date | Status |
|---|---|---|---|---|
| United States | GUDID listing | Number10885862661470 | Date19 Mar 2026 | StatusListed |
| United States | FDA 510(k)SESE | NumberK071676 | Date19 Jul 2007 | StatusActive |
Official records
- AccessGUDID record 10885862661470
- FDA 510(k) database K071676
From the FDA record
- Device description
- Removal Tool, Constraining Ring
- MRI safety
- Labeling does not contain MRI Safety Information
- Natural rubber latex
- No latex statement on the label
- Sterility
- Supplied non-sterile; sterilise before use (Moist Heat or Steam Sterilization)
Across registries
- FDA 510(k) K071676 decided 19 Jul 2007 Active
- FDA GUDID UDI-DI 10885862661470 listed 19 Mar 2026 Listed
Recalls
-
- Ongoing Z-0581-2024
Exactech has received 3 complaints for 4 devices related to a loss of vacuum in the inner-most vacuum bag.
-
- Ongoing Z-1730-2022
Specific GXL acetabular polyethylene liners, packaged in non-conforming bags, may adversely impact the device and contribute to accelerated wear.
Timeline
- Cleared FDA 510(k) K071676
- Recall initiated FDA recalls Z-1730-2022
- Recall initiated FDA recalls Z-0581-2024
- Listed FDA GUDID 10885862661470
Coverage
- Active
- Expiring
- Withdrawn
- Listed
- Not covered
United States — FDA 510(k) Active
Specification
- Generic name
- Orthopaedic inorganic implant inserter/extractor, reusable
- Model / Ref / Catalog
- 181-03-03
- Primary DI / UDI-DI
- 10885862661470
- 510(k) Number
- FDA product code
- KWZ
- GMDN term
- Orthopaedic inorganic implant inserter/extractor, reusable
- Device class
- Class II
- Regulation number
- 888.3310
- GUDID distribution status
- In Commercial Distribution
- Sterilisation method
- Moist Heat or Steam Sterilization
Similar devices
Other devices filed under FDA product code KWZ (Prosthesis, hip, constrained, cemented or uncemented, metal/polymer).
- Continuum® Trilogy® Allofit® 00-8738-022-32 by Zimmer, Inc.
- G7® 010002630 by Biomet Orthopedics, Inc.
- G7® Acetabular System 110017403 by Biomet Orthopedics, Inc.
- 00-5851-003-10 by Zimmer, Inc.
- M-Vizion Femoral Revision System Extension 01.22.10.0402 by Medacta International SA
- S-ROM Poly-Dial Constrained Acetabular Liner by Depuy, A Johnson & Johnson Co.
- MINIMA S Uncemented Stem 4503.21.080 by Limacorporate
- EXPRT Revision Hip System by ENCORE MEDICAL, L.P.
- MINIMA S Uncemented Stem 4503.21.050 by Limacorporate
- INSTRUMENT 1020-1800 by Howmedica Osteonics Corp.