Skip to content

Ibi-85739

by Irvine Biomedical, Inc.

Part of a family of 22 devices: see the family page

Ref IBI-85739

Ibi-85739 is an electrical-only medical device connection cable (EU MDR Class I; FDA Class III; FDA product code OAD, catheter, percutaneous, cardiac ablation, for treatment of atrial flutter) made by Irvine Biomedical, Inc., registered in EUDAMED on 24 Aug 2026 (Basic UDI-DI 5414734ABR0026BQ), approved under FDA PMA P040042 on 18 Nov 2005 and listed in FDA GUDID since 31 Oct 2014 (UDI-DI 05414734308939), active as of 23 Oct 2026. 2 FDA recalls are linked to it.

Active European Union and United States. Also listed in GUDID (US).

CE MDR PMA

Valid until

No date given

CE: no date in EUDAMED. FDA: not time-limited

FDA recalls

None ongoing

4 closed

Documents

None linked in EUDAMED

A group certificate may exist

PMA P040042

FDA submission, from GUDID

Trust

Unverified

Source EUDAMED, GUDID, synced 23 Oct 2026.

Regulatory status

as of registry sync 23 Oct 2026

RegionAuthorizationNumberDateStatus
European UnionCE/MDR EUDAMED Number5414734ABR0026BQ Basic UDI-DI 05414734308939UDI-DIDate24 Aug 2026RegisteredStatusActive
United StatesGUDID listing GUDID Number05414734308939 UDI-DI Date31 Oct 2014ListedStatusListed GUDID: in commercial distribution
United StatesFDA PMAAPPR GUDID from GUDID Approved NumberP040042 Date18 Nov 2005DecidedStatusActive

Official records

From the FDA record

Device description
1739-W Electrophysiology Cable
MRI safety
Labeling does not contain MRI Safety Information
Natural rubber latex
No latex statement on the label
Sterility
Supplied sterile; sterilise before use (Ethylene Oxide)

From the GUDID record (AccessGUDID), as read on 23 Oct 2026, as the labeller entered it.

Across registries

3 registries list this device

  • EUDAMED Basic UDI-DI 5414734ABR0026BQ registered 24 Aug 2026 Active
  • FDA PMA P040042 decided 18 Nov 2005 Active
  • FDA GUDID UDI-DI 05414734308939 listed 31 Oct 2014 Listed

Recalls

4 recalls · FDA

    • Terminated Z-0593-2010 FDA Unclassified (pre-2012) initiated 25 Nov 2009

    This action is being taken because the product has the potential for the polyimide tubing to detach from the inner core due to the bond failure. If this occurs, treatment may be delayed or interrupted. The firm's initial health hazard analysis indicated the event may cause temporary or medically reversible adverse health consequences or an outcome where the probability of serious adverse health c

    • Terminated Z-0594-2010 FDA Unclassified (pre-2012) initiated 25 Nov 2009

    This action is being taken because the product has the potential for the polyimide tubing to detach from the inner core due to the bond failure. If this occurs, treatment may be delayed or interrupted. The firm's initial health hazard analysis indicated the event may cause temporary or medically reversible adverse health consequences or an outcome where the probability of serious adverse health

  • 2 recalls, same reason

    • Terminated Z-0309-2007 FDA Unclassified (pre-2012) initiated 8 Nov 2006 on shared PMA P040042
    • Terminated Z-0310-2007 FDA Unclassified (pre-2012) initiated 8 Nov 2006 on shared PMA P040042

    Recall was initiated after a clinical incident involving separation of the front sheath, preventing deployment of the stent graft. This required the physician to convert the patient to conventional open repair.

Recalls on a shared submission name another device cleared under the same FDA submission as this one.

Timeline

7 dated events

  1. Approved FDA PMA P040042
  2. Recall initiated FDA recalls Z-0309-2007
  3. Recall initiated FDA recalls Z-0310-2007
  4. Recall initiated FDA recalls Z-0593-2010
  5. Recall initiated FDA recalls Z-0594-2010
  6. Listed FDA GUDID 05414734308939
  7. Registered EUDAMED 5414734ABR0026BQ

Coverage

2 jurisdictions

United States of AmericaSwedenFinlandLatviaEstoniaDenmarkLithuaniaIrelandNetherlandsGermanyPolandFranceBelgiumLuxembourgCzech RepublicSlovakiaAustriaHungaryRomaniaSloveniaBulgariaPortugalSpainItalyCroatiaGreeceMaltaCyprus
  • Active
  • Expiring
  • Withdrawn
  • Listed
  • Not covered
  • European Union CE/MDR Active
  • United States FDA PMA Active

Specification

EUDAMED · GUDID

Generic name
Electrical-only medical device connection cable, reprocessed
Device name
Sterile Cables
Model / Ref / Catalog
IBI-85739
Primary DI / UDI-DI
05414734308939
Basic UDI-DI
5414734ABR0026BQ
Direct marketing DI
05414734308939
PMA number
FDA product code
OAD
EMDN code
L0317 General surgery adapters and connectors, reusable
GMDN term
Electrical-only medical device connection cable, reprocessed
Device class
Class I EUDAMED
Class III GUDID
EU registration type
Standard device
EU market of registration
Belgium
GUDID distribution status
In Commercial Distribution
Sterilisation method
Ethylene Oxide
Size
Length — 8 Feet
Length — 2.5000 Meter

Truth per registry

2 sources · 1 field differs

FieldEUDAMEDGUDID
Device classEUDAMED
Class I
GUDID
Class III

Device class is stated on each registry's own scale: Class I in the EU (EUDAMED), Class III in the US (FDA GUDID). EU and US classes are different schemes, so this is not a disagreement.

Similar devices in this category

Other devices filed under GENERAL SURGERY ADAPTERS AND CONNECTORS, REUSABLE.

Other devices from Irvine Biomedical, Inc.(Ibi)

See all devices from Irvine Biomedical, Inc.(Ibi) →

Properties

  • Supplied sterile
  • Sterilise before use
  • Prescription use
  • Lot / batch number
  • Expiration date
Other properties (20, all answered No)