Ibi-85739
Part of a family of 22 devices: see the family page
Ref IBI-85739
Ibi-85739 is an electrical-only medical device connection cable (EU MDR Class I; FDA Class III; FDA product code OAD, catheter, percutaneous, cardiac ablation, for treatment of atrial flutter) made by Irvine Biomedical, Inc., registered in EUDAMED on 24 Aug 2026 (Basic UDI-DI 5414734ABR0026BQ), approved under FDA PMA P040042 on 18 Nov 2005 and listed in FDA GUDID since 31 Oct 2014 (UDI-DI 05414734308939), active as of 23 Oct 2026. 2 FDA recalls are linked to it.
Active
Valid until
No date given
FDA recalls
None ongoingTrust
Regulatory status
| Region | Authorization | Number | Date | Status |
|---|---|---|---|---|
| European Union | CE/MDR EUDAMED | Number5414734ABR0026BQ 05414734308939 | Date24 Aug 2026 | StatusActive |
| United States | GUDID listing GUDID | Number05414734308939 | Date31 Oct 2014 | StatusListed |
| United States | FDA PMAAPPR GUDID | NumberP040042 | Date18 Nov 2005 | StatusActive |
Official records
- EUDAMED public site 5414734ABR0026BQ
- AccessGUDID record 05414734308939
- FDA PMA database P040042
From the FDA record
- Device description
- 1739-W Electrophysiology Cable
- MRI safety
- Labeling does not contain MRI Safety Information
- Natural rubber latex
- No latex statement on the label
- Sterility
- Supplied sterile; sterilise before use (Ethylene Oxide)
Across registries
- EUDAMED Basic UDI-DI 5414734ABR0026BQ registered 24 Aug 2026 Active
- FDA PMA P040042 decided 18 Nov 2005 Active
- FDA GUDID UDI-DI 05414734308939 listed 31 Oct 2014 Listed
Recalls
-
- Terminated Z-0593-2010
This action is being taken because the product has the potential for the polyimide tubing to detach from the inner core due to the bond failure. If this occurs, treatment may be delayed or interrupted. The firm's initial health hazard analysis indicated the event may cause temporary or medically reversible adverse health consequences or an outcome where the probability of serious adverse health c
-
- Terminated Z-0594-2010
This action is being taken because the product has the potential for the polyimide tubing to detach from the inner core due to the bond failure. If this occurs, treatment may be delayed or interrupted. The firm's initial health hazard analysis indicated the event may cause temporary or medically reversible adverse health consequences or an outcome where the probability of serious adverse health
-
- Terminated Z-0309-2007
- Terminated Z-0310-2007
Recall was initiated after a clinical incident involving separation of the front sheath, preventing deployment of the stent graft. This required the physician to convert the patient to conventional open repair.
Timeline
- Approved FDA PMA P040042
- Recall initiated FDA recalls Z-0309-2007
- Recall initiated FDA recalls Z-0310-2007
- Recall initiated FDA recalls Z-0593-2010
- Recall initiated FDA recalls Z-0594-2010
- Listed FDA GUDID 05414734308939
- Registered EUDAMED 5414734ABR0026BQ
Coverage
- Active
- Expiring
- Withdrawn
- Listed
- Not covered
- European Union
- United States
Specification
- Generic name
- Electrical-only medical device connection cable, reprocessed
- Device name
- Sterile Cables
- Model / Ref / Catalog
- IBI-85739
- Primary DI / UDI-DI
- 05414734308939
- Basic UDI-DI
- 5414734ABR0026BQ
- Direct marketing DI
- 05414734308939
- PMA number
- FDA product code
- OAD
- EMDN code
- L0317 General surgery adapters and connectors, reusable
- GMDN term
- Electrical-only medical device connection cable, reprocessed
- Device class
- Class I EUDAMEDClass III GUDID
- EU registration type
- Standard device
- EU market of registration
- Belgium
- GUDID distribution status
- In Commercial Distribution
- Sterilisation method
- Ethylene Oxide
- Size
- Length — 8 FeetLength — 2.5000 Meter
Truth per registry
| Field | EUDAMED | GUDID |
|---|---|---|
| Device class | Class I | Class III |
Similar devices in this category
Other devices filed under GENERAL SURGERY ADAPTERS AND CONNECTORS, REUSABLE.
- SD Handpiece Hex Adapter-Short MSD0062 by MEDIGMA BIOMEDICAL GMBH
- WP Handpiece Hex Adapter-Short WP0062 by ADIN DENTAL IMPLANT SYSTEMS LTD
- Uni FB adapter for tibial resection 42160372 by implantcast GmbH
- Implantcast Packaging System Update by implantcast GmbH
- UNP 2mm Hex Handpiece Adapter - Short UNP0068 by ADIN DENTAL IMPLANT SYSTEMS LTD
- WD Handpiece Hex Adapter-Long MWD0072 by MEDIGMA BIOMEDICAL GMBH
- PadPro ZMUF by Conmed Corporation
- Valleylab E0507B by Covidien LP
- ENTREE 7457 by Conmed Corporation
- RFP-100A Connector Cable RFX-BAY-TS by Baylis Médicale Cie Inc