Skip to content

2358-02-12

by Zimmer, Inc.

Ref 00-2358-002-12

2358-02-12 (00-2358-002-12) is a device classified as Class IIb in the EU and Class II in the US made by Zimmer, Inc., registered in EUDAMED on 2 Nov 2026 (Basic UDI-DI 889024-ZB001057-F7), cleared under FDA 510(k) K141734 on 13 Aug 2014 (1 earlier submission) and listed in FDA GUDID since 16 Oct 2015 (UDI-DI 00889024056114), active as of 7 Nov 2026. 3 FDA recalls are linked to it.

Active European Union and United States. Also listed in GUDID (US).

CE MDR 510(k)

Valid until

No date given

CE: no date in EUDAMED. FDA: not time-limited

FDA recalls

1 ongoing

This device is named in the recall

Documents

None linked in EUDAMED

A group certificate may exist

Trust

Unverified

Source EUDAMED, GUDID, synced 7 Nov 2026.

Regulatory status

as of registry sync 7 Nov 2026

RegionAuthorizationNumberDateStatus
European UnionCE/MDR EUDAMED Number889024-ZB001057-F7 Basic UDI-DI 00889024056114UDI-DIDate2 Nov 2026RegisteredStatusActive
United StatesGUDID listing GUDID Number00889024056114 UDI-DI Date16 Oct 2015ListedStatusListed GUDID: in commercial distribution
United StatesFDA 510(k)SESE GUDID from GUDID Substantially Equivalent · Traditional NumberK141734 Date13 Aug 2014DecidedStatusActive

Official records

Across registries

3 registries list this device

  • EUDAMED Basic UDI-DI 889024-ZB001057-F7 registered 2 Nov 2026 Active
  • FDA 510(k) K141734 decided 13 Aug 2014 Active· +1 more in the status table
  • FDA GUDID UDI-DI 00889024056114 listed 16 Oct 2015 Listed

Recalls

3 recalls · 1 ongoing · FDA

    • Ongoing Z-2254-2023 FDA Class II initiated 27 Jun 2023

    Thread form issue of the locking holes in that the locking screws would not properly mate with the plate. The improperly mated screw may not be readily recognizable by the user since the screw may not correctly lock.

  • 2 recalls, same reason

    • Terminated Z-0317-2020 FDA Class II initiated 10 Oct 2019
    • Terminated Z-0310-2020 FDA Class II initiated 10 Oct 2019

    Non-highly polished implants may adhere to the LDPE bag (previous packaging configuration).

Timeline

7 dated events

  1. Cleared FDA 510(k) K043227
  2. Cleared FDA 510(k) K141734
  3. Listed FDA GUDID 00889024056114
  4. Recall initiated FDA recalls Z-0317-2020
  5. Recall initiated FDA recalls Z-0310-2020
  6. Recall initiated FDA recalls Z-2254-2023
  7. Registered EUDAMED 889024-ZB001057-F7

Coverage

2 jurisdictions

United States of AmericaSwedenFinlandLatviaEstoniaDenmarkLithuaniaIrelandNetherlandsGermanyPolandFranceBelgiumLuxembourgCzech RepublicSlovakiaAustriaHungaryRomaniaSloveniaBulgariaPortugalSpainItalyCroatiaGreeceMaltaCyprus
  • Active
  • Expiring
  • Withdrawn
  • Listed
  • Not covered
  • European Union CE/MDR Active
  • United States FDA 510(k) Active

Specification

EUDAMED · GUDID

Trade name
Zimmer® Periarticular Locking Plate System
Generic name
Orthopaedic fixation plate, non-bioabsorbable
Device name
ZPLP Plate Humoral Proximal Lateral Left
Model / Ref / Catalog
00-2358-002-12, 2358-02-12
Primary DI / UDI-DI
00889024056114
Basic UDI-DI
889024-ZB001057-F7
510(k) Number
FDA product code
HRS
EMDN code
P09120503 Osteosynthesis screw-plate systems
GMDN term
Orthopaedic fixation plate, non-bioabsorbable
Device class
Class IIb EUDAMED
Class II GUDID
Regulation number
888.3030
EU registration type
Standard device
EU market of registration
Netherlands
GUDID distribution status
In Commercial Distribution
Sterilisation method
Moist Heat or Steam Sterilization
Size
Length — 186 Millimeter

Truth per registry

2 sources · 2 fields differ

FieldEUDAMEDGUDID
Model / referenceEUDAMED
00-2358-002-12
GUDID
2358-02-12
Device classEUDAMED
Class IIb
GUDID
Class II

Device class is stated on each registry's own scale: Class IIb in the EU (EUDAMED), Class II in the US (FDA GUDID). EU and US classes are different schemes, so this is not a disagreement.

Similar devices in this category

Other devices filed under OSTEOSYNTHESIS SCREW-PLATE SYSTEMS.

Other devices from Zimmer, Inc.

See all devices from Zimmer, Inc. →

Properties

  • Sterilise before use
  • Single use
  • Implantable
  • Sutures
  • Contains CMR substances (carcinogenic, mutagenic or toxic to reproduction)
  • Prescription use
  • Lot / batch number
Other properties (19, all answered No)