by Exactech, Inc.

161-00-07 is a bone-resection orthopaedic reamer (FDA Class II) made by Exactech, Inc., cleared under FDA 510(k) K102487 on 8 Nov 2010 (4 earlier submissions) and listed in FDA GUDID since 28 Jul 2022 (UDI-DI 10885862033253), active as of 23 Oct 2026. 3 FDA recalls are linked to it.

Active United States. Also listed in GUDID (US).

510(k)

Valid until

No expiry

510(k) clearance is not time-limited

FDA recalls

None ongoing

3 closed

Documents

Trust

Unverified

Source GUDID, synced 23 Oct 2026.

Regulatory status

as of registry sync 23 Oct 2026

RegionAuthorizationNumberDateStatus
United StatesGUDID listing Number10885862033253 UDI-DI Date28 Jul 2022ListedStatusListed GUDID: in commercial distribution
United StatesFDA 510(k)SESE from GUDID Substantially Equivalent · Special NumberK102487 Date8 Nov 2010DecidedStatusActive

Official records

From the FDA record

Device description
REPLACEMENT CALCAR BLADE
MRI safety
Labeling does not contain MRI Safety Information
Natural rubber latex
No latex statement on the label
Sterility
Supplied non-sterile; sterilise before use (Moist Heat or Steam Sterilization)

From the GUDID record (AccessGUDID), as read on 23 Oct 2026, as the labeller entered it.

Across registries

2 registries list this device

  • FDA 510(k) K102487 decided 8 Nov 2010 Active· +4 more in the status table
  • FDA GUDID UDI-DI 10885862033253 listed 28 Jul 2022 Listed

Recalls

3 recalls · FDA

    • Terminated Z-1030-2017 FDA Class II initiated 7 Nov 2016

    Products were labeled with incorrect Global Trade Item Numbers. The GTIN on the label identifies the devices as another.

  • 2 recalls, same reason

    • Terminated Z-2127-2016 FDA Class II initiated 26 May 2016
    • Terminated Z-2128-2016 FDA Class II initiated 26 May 2016

    Labeled with the incorrect Global Trade Item Number (GTIN). The GTIN on the label identifies the devices as another.

Timeline

9 dated events

  1. Cleared FDA 510(k) K042842
  2. Cleared FDA 510(k) K052787
  3. Cleared FDA 510(k) K063279
  4. Cleared FDA 510(k) K083392
  5. Cleared FDA 510(k) K102487
  6. Recall initiated FDA recalls Z-2127-2016
  7. Recall initiated FDA recalls Z-2128-2016
  8. Recall initiated FDA recalls Z-1030-2017
  9. Listed FDA GUDID 10885862033253

Coverage

1 jurisdiction

United States of America
  • Active
  • Expiring
  • Withdrawn
  • Listed
  • Not covered

United States — FDA 510(k) Active

Specification

GUDID

Generic name
Bone-resection orthopaedic reamer, reusable
Model / Ref / Catalog
161-00-07
Primary DI / UDI-DI
10885862033253
FDA product code
MEH, LZO, LWJ, JDI
GMDN term
Bone-resection orthopaedic reamer, reusable
Device class
Class II
Regulation number
888.3353, 888.3360, 888.3350
GUDID distribution status
In Commercial Distribution
Sterilisation method
Moist Heat or Steam Sterilization

Similar devices in this category

Other devices filed under Bone-resection orthopaedic reamer, reusable.

Other devices from Exactech, Inc.

See all devices from Exactech, Inc. →

Properties

  • Sterilise before use
  • Prescription use
  • Lot / batch number
Other properties (12, all answered No)