# 2326

> Active: European Union and United States. Medical device record on deviCERTS, compiled from public registries.

- Canonical page: <https://devicerts.com/devices/na-2326>
- Manufacturer: [St. Jude Medical, Inc.](https://devicerts.com/manufacturers/st-jude-medical-inc) (United States, FDA PMA applicant)
- Device class: Class III (EU MDR / US FDA)
- FDA product code: LGW
- EMDN: J0280 IMPLANTABLE NEUROSTIMULATORS - ACCESSORIES
- GMDN: Neural-tissue electrical stimulation lead adaptor (48054)

## Registrations and authorizations

- **EUDAMED** · CE/MDR · European Union · Basic UDI-DI 5415067ACC000254 · UDI-DI 05415067016140 · registered 2026-08-25 · status: Active
- **EUDAMED** · CE/MDR · European Union · MDR 779805 · issued 2026-06-25 · expires 2028-12-11 · status: Active
- **GUDID** · GUDID listing · United States · UDI-DI 05415067016140 · listed 2015-04-22 · status: Listed (GUDID: in commercial distribution)
- **GUDID** · FDA PMA · United States · P010032 · decision 2001-11-21 · decision APPR · status: Active · from GUDID

## EU certificates

- MDR 779805 · Technical documentation · MDR · notified body BSI Group The Netherlands B.V. · issued 2026-06-25 · expires 2028-12-11 · status: supplemented

## Recalls

- Z-0458-2026 · Class II · ongoing · initiated 2025-10-06: There is a potential issue affecting Eterna Spinal Cord Stimulation (SCS) Implantable Pulse Generators (IPGs), Model 32400 and Liberta RC Deep Brain Stimulation (DBS) Implantable Pulse Generators (IPGs), Model 62400 . These devicess may experience a loss of communication with the Clinician Programmer (CP) and/or the Patient Controller (PC).
- Z-2505-2023 · Class I · ongoing · initiated 2023-07-18: Firm has received complaints from patients who are unable to exit MRI (Magnetic Resonance Imaging) mode on their IPGs (Implantable Pulse Generators).
- Z-2506-2023 · Class I · ongoing · initiated 2023-07-18: Firm has received complaints from patients who are unable to exit MRI (Magnetic Resonance Imaging) mode on their IPGs (Implantable Pulse Generators).
- Z-2507-2023 · Class I · ongoing · initiated 2023-07-18: Firm has received complaints from patients who are unable to exit MRI (Magnetic Resonance Imaging) mode on their IPGs (Implantable Pulse Generators).
- Z-2508-2023 · Class I · ongoing · initiated 2023-07-18: Firm has received complaints from patients who are unable to exit MRI (Magnetic Resonance Imaging) mode on their IPGs (Implantable Pulse Generators).
- Z-2509-2023 · Class I · ongoing · initiated 2023-07-18: Firm has received complaints from patients who are unable to exit MRI (Magnetic Resonance Imaging) mode on their IPGs (Implantable Pulse Generators).
- Z-2510-2023 · Class I · ongoing · initiated 2023-07-18: Firm has received complaints from patients who are unable to exit MRI (Magnetic Resonance Imaging) mode on their IPGs (Implantable Pulse Generators).
- Z-2511-2023 · Class I · ongoing · initiated 2023-07-18: Firm has received complaints from patients who are unable to exit MRI (Magnetic Resonance Imaging) mode on their IPGs (Implantable Pulse Generators).
- Z-2691-2017 · Class II · terminated · initiated 2017-06-02: The firm discovered a risk of loss of Neuromodulation therapy due to exposure of the IPG to monopolar electrosurgical devices (ESU) during medical procedures.
- Z-2692-2017 · Class II · terminated · initiated 2017-06-02: The firm discovered a risk of loss of Neuromodulation therapy due to exposure of the IPG to monopolar electrosurgical devices (ESU) during medical procedures.
- Z-1785-2013 · Class II · terminated · initiated 2012-11-30: There is issues of warmth or heating at the implant site during charging for the Eon Mini implantable pulse generators (IPGs). In the July 2012 letter St. Jude Medical informed customers that they would be implementing design improvements to the charger to address possible increased energy dissipation when the charger is misaligned with the IPG or the IPG is implanted too near the surface of the
- Z-0025-2013 · Class II · terminated · initiated 2012-09-04: Eon Mini IPGs manufactured in April 2012 could potentially exhibit a sudden, brief surge in stimulation that would be felt by the patient as uncomfortable or painful. SJMs routine testing, monitoring, and analysis of manufacturing processes identified three lots of Eon Mini IPGs that the internal battery has the potential to come into contact with the internal microcontroller board.
- Z-1738-2013 · Class II · terminated · initiated 2012-07-26: St. Jude Medical has informed your doctor that a number of cases have been reported in which discomfort associated with heating occurred at the device site while patients were using the Charging System to charge their spinal cord stimulator. In three cases, patients received a burn to the skin (one second-degree and two first-degree burns) at the implant site. As of June 30, 2012, St. Jude Medica
- Z-3091-2011 ·  · terminated · initiated 2009-06-02: Product programmed with unapproved software was distributed.

## Identity

- Generic name: Neural-tissue electrical stimulation lead adaptor [FDA GUDID (AccessGUDID)]
- Device name: Neuromodulation Accessories [EUDAMED]
- Model / Ref / Catalog: 2326 [EUDAMED, FDA GUDID (AccessGUDID)]

## Identifiers

- Primary DI / UDI-DI: 05415067016140 [EUDAMED, FDA GUDID (AccessGUDID)]
- Basic UDI-DI: 5415067ACC000254 [EUDAMED]
- PMA number: P010032 [FDA GUDID (AccessGUDID)]
- FDA product code: LGW [FDA GUDID (AccessGUDID)]
- EMDN code: J0280 [EUDAMED]
- GMDN term: Neural-tissue electrical stimulation lead adaptor (48054) [FDA GUDID (AccessGUDID)]

## Classification

- Device class: Class III [EUDAMED, FDA GUDID (AccessGUDID)]
- EU registration type: Standard device [EUDAMED]
- EU market of registration: Belgium [EUDAMED]
- GUDID distribution status: In Commercial Distribution [FDA GUDID (AccessGUDID)]

## Dimensions & Sizes

- Size: Length — 60 Centimeter [FDA GUDID (AccessGUDID)]

## Properties

- Supplied sterile: Yes [EUDAMED, FDA GUDID (AccessGUDID)]
- Single use: Yes [FDA GUDID (AccessGUDID)]
- Implantable: Yes [EUDAMED, FDA GUDID (AccessGUDID)]
- Contains CMR substances (carcinogenic, mutagenic or toxic to reproduction): Yes [EUDAMED]
- Prescription use: Yes [FDA GUDID (AccessGUDID)]
- Lot / batch number: Yes [FDA GUDID (AccessGUDID)]
- Expiration date: Yes [FDA GUDID (AccessGUDID)]
- Sterilise before use: No [EUDAMED, FDA GUDID (AccessGUDID)]
- Reusable: No [EUDAMED]
- Contains latex: No [EUDAMED, FDA GUDID (AccessGUDID)]
- Reprocessed single-use device: No [EUDAMED]
- Incorporates a substance derived from human blood or plasma: No [EUDAMED]
- Contains human tissues or cells: No [EUDAMED]
- Contains animal tissues or cells: No [EUDAMED]
- Contains endocrine-disrupting substances: No [EUDAMED]
- Administering medicine: No [EUDAMED]
- Measuring function: No [EUDAMED]
- Incorporates a medicinal substance: No [EUDAMED]
- Over-the-counter: No [FDA GUDID (AccessGUDID)]
- Convenience kit: No [FDA GUDID (AccessGUDID)]
- Combination product: No [FDA GUDID (AccessGUDID)]
- HCT/P: No [FDA GUDID (AccessGUDID)]
- Premarket exempt: No [FDA GUDID (AccessGUDID)]
- Serial number: No [FDA GUDID (AccessGUDID)]
- Manufacturing date: No [FDA GUDID (AccessGUDID)]

## Source and citation

- Cite as: 2326, St. Jude Medical, Inc. deviCERTS medical device catalogue. https://devicerts.com/devices/na-2326 (data as of 2026-11-24).
- Data sources: [FDA GUDID (AccessGUDID)](https://accessgudid.nlm.nih.gov/), [EUDAMED](https://ec.europa.eu/tools/eudamed), [FDA recalls](https://open.fda.gov/apis/device/recall/)
- Registry records last synced: 2026-10-24
- Statuses computed as of: 2026-11-24
- JSON: <https://devicerts.com/devices/na-2326.json>
- Licence: [CC BY 4.0](https://creativecommons.org/licenses/by/4.0/). The deviCERTS layout and text are licensed under CC BY 4.0. Registry data remain under their source terms: U.S. FDA data (openFDA, AccessGUDID) are U.S. public domain; EUDAMED data are subject to the European Commission reuse terms.
- Attribution: DevicErts, https://devicerts.com/devices/na-2326
- Compiled by deviCERTS (devicerts.com) from public medical device registries (EUDAMED, European Commission; U.S. FDA via openFDA; AccessGUDID, U.S. National Library of Medicine). deviCERTS is not an official register and gives no regulatory advice: the record in the registry itself prevails.