351.718S
by Synthes GmbH
351.718S (351718S) is a surgical power tool drive-shaft seal (FDA Class I) made by Synthes GmbH, cleared under FDA 510(k) K111437 on 10 Aug 2011 (2 earlier submissions) and listed in FDA GUDID since 30 Jun 2016 (UDI-DI 20886982193947), active as of 12 Nov 2026. 19 FDA recalls are linked to it.
Active
Valid until
No expiry
FDA recalls
1 ongoingDocuments
Trust
Regulatory status
| Region | Authorization | Number | Date | Status |
|---|---|---|---|---|
| United States | GUDID listing | Number20886982193947 | Date30 Jun 2016 | StatusListed |
| United States | FDA 510(k)SESE | NumberK111437 | Date10 Aug 2011 | StatusActive |
Official records
- AccessGUDID record 20886982193947
- FDA 510(k) database K111437
- FDA 510(k) database K042899
- FDA 510(k) database K013527
From the FDA record
- Device description
- DRIVE SHAFT SEAL-STERILE FOR RIA
- MRI safety
- Labeling does not contain MRI Safety Information
- Natural rubber latex
- No latex statement on the label
- Sterility
- Supplied sterile
Across registries
- FDA 510(k) K111437 decided 10 Aug 2011 Active
- FDA GUDID UDI-DI 20886982193947 listed 30 Jun 2016 Listed
Recalls
-
- Ongoing Z-1237-2024
Products not sterilized, sterility cannot be confirmed
-
- Terminated Z-0573-2021
- Terminated Z-0571-2021
- Terminated Z-0574-2021
- Terminated Z-0577-2021
- Terminated Z-0581-2021
- Terminated Z-0580-2021
- Terminated Z-0585-2021
- Terminated Z-0586-2021
- Terminated Z-0575-2021
- Terminated Z-0576-2021
- Terminated Z-0582-2021
- Terminated Z-0587-2021
- Terminated Z-0583-2021
- Terminated Z-0584-2021
- Terminated Z-0572-2021
- Terminated Z-0578-2021
- Terminated Z-0579-2021
RIA 2 reamer head breakage exceeds the expected occurrence rate resulting in adverse tissue reaction, soft tissue damage, and/or bone damage, when the recommended surgical techniques are not followed
-
- Terminated Z-2092-2015
It was reported that the RIA Drive Shaft, Tube Assembly, and Reamer Head have the potential to break when incorrectly assembled or used improperly. Precautionary statements are being added to the Reamer / Irrigator / Aspirator (RIA) Surgical Technique Guide.
Timeline
- Recall initiated FDA recalls Z-0575-2021
- Recall initiated FDA recalls Z-0576-2021
- Recall initiated FDA recalls Z-0582-2021
- Recall initiated FDA recalls Z-0587-2021
- Recall initiated FDA recalls Z-0583-2021
- Recall initiated FDA recalls Z-0584-2021
- Recall initiated FDA recalls Z-0572-2021
- Recall initiated FDA recalls Z-0578-2021
- Recall initiated FDA recalls Z-0579-2021
- Recall initiated FDA recalls Z-1237-2024
Coverage
- Active
- Expiring
- Withdrawn
- Listed
- Not covered
United States — FDA 510(k) Active
Specification
- Generic name
- Surgical power tool drive-shaft seal
- Model / Ref / Catalog
- 351.718S, 351718S
- Primary DI / UDI-DI
- 20886982193947
- FDA product code
- HTO, HRX
- GMDN term
- Surgical power tool drive-shaft seal
- Device class
- Class I
- Regulation number
- 888.4540, 888.1100
- GUDID distribution status
- In Commercial Distribution
Similar devices
Other devices filed under FDA product code HTO (REAMER).
- Precision 110010579 by Biomet Orthopedics, Inc.
- APEX Knee System KR-53260 by OMNIlife science, Inc.
- FLEXIBLE INTRAMEDULLARY REAMER by Zimmer, Inc.
- Tornier Radial Head System MTJ009 by TORNIER, INC.
- APEX Knee System KR-53180 by OMNIlife science, Inc.
- Pressure Sentinel® 2228-25-05 00-2228-025-05 by Zimmer, Inc.
- Universal Taper 1 424456 by Biomet Orthopedics, Inc.
- ACS® Uni SG femoral reamer 42160332 by implantcast GmbH
- U2 Total Knee System 9323-3514 by UNITED ORTHOPEDIC CORP.