# 47-2480-026-41

> Active: United States. Medical device record on deviCERTS, compiled from public registries.

- Canonical page: <https://devicerts.com/devices/na-47-2480-026-41>
- Manufacturer: [Zimmer, Inc.](https://devicerts.com/manufacturers/zimmer-inc) (United States)
- Device class: Class II (US FDA)
- FDA product code: JDI, HWC
- GMDN: Orthopaedic bone screw (non-sliding) (66947)

## Registrations and authorizations

- **GUDID** · GUDID listing · United States · UDI-DI 00889024093034 · listed 2015-09-24 · status: Listed (GUDID: in commercial distribution)
- **GUDID** · FDA 510(k) · United States · K112885 · decision 2011-12-19 · decision SESE · status: Active · from GUDID

## Recalls

- Z-1677-2016 · Class II · terminated · initiated 2016-05-04 · matched through shared submission K112885, may concern other models: A small hole may be present in the inner tray of specific lots of sterile Hip and Trauma Implant Screws.
- Z-1102-2016 · Class II · terminated · initiated 2016-01-11 · matched through shared submission K112885, may concern other models: As a result of the insufficient sealer calibration data for product packaged in firm's Building II between August 2010 and April 2013. The affected products are sterile.
- Z-1108-2016 · Class II · terminated · initiated 2016-01-11 · matched through shared submission K112885, may concern other models: As a result of the insufficient sealer calibration data for product packaged in firm's Building II between August 2010 and April 2013. The affected products are sterile.
- Z-1111-2016 · Class II · terminated · initiated 2016-01-11 · matched through shared submission K112885, may concern other models: As a result of the insufficient sealer calibration data for product packaged in firm's Building II between August 2010 and April 2013. The affected products are sterile.
- Z-1116-2016 · Class II · terminated · initiated 2016-01-11 · matched through shared submission K112885, may concern other models: As a result of the insufficient sealer calibration data for product packaged in firm's Building II between August 2010 and April 2013. The affected products are sterile.
- Z-2244-2014 · Class II · terminated · initiated 2014-07-22 · matched through shared submission K112885, may concern other models: Zimmer is recalling various trauma screws that failed a leak test due to damage of the inner cavity only.
- Z-2245-2014 · Class II · terminated · initiated 2014-07-22 · matched through shared submission K112885, may concern other models: Zimmer is recalling various trauma screws that failed a leak test due to damage of the inner cavity only.
- Z-2246-2014 · Class II · terminated · initiated 2014-07-22 · matched through shared submission K112885, may concern other models: Zimmer is recalling various trauma screws that failed a leak test due to damage of the inner cavity only.
- Z-2247-2014 · Class II · terminated · initiated 2014-07-22 · matched through shared submission K112885, may concern other models: Zimmer is recalling various trauma screws that failed a leak test due to damage of the inner cavity only.
- Z-2248-2014 · Class II · terminated · initiated 2014-07-22 · matched through shared submission K112885, may concern other models: Zimmer is recalling various trauma screws that failed a leak test due to damage of the inner cavity only.
- Z-2249-2014 · Class II · terminated · initiated 2014-07-22 · matched through shared submission K112885, may concern other models: Zimmer is recalling various trauma screws that failed a leak test due to damage of the inner cavity only.
- Z-2250-2014 · Class II · terminated · initiated 2014-07-22 · matched through shared submission K112885, may concern other models: Zimmer is recalling various trauma screws that failed a leak test due to damage of the inner cavity only.
- Z-2251-2014 · Class II · terminated · initiated 2014-07-22 · matched through shared submission K112885, may concern other models: Zimmer is recalling various trauma screws that failed a leak test due to damage of the inner cavity only.
- Z-1040-2014 · Class II · terminated · initiated 2013-10-11 · matched through shared submission K112885, may concern other models: Zimmer recently conducted a review of all historic packaging validations at its Zimmer Manufacturing B.V. (ZMBV) facility in Ponce, Puerto Rico. Based on this review, it was determined that the packaging operations conducted in the Building 1 packaging operation at this facility were not properly validated. As a result, Zimmer conducted seal integrity testing to evaluate if previously packaged product from this facility met the established requirements for sterile barrier integrity. The acceptance criteria established for this testing was 99% reliability with a 90% confidence interval. These packaging tray configurations met the acceptance criteria for sterile barrier integrity of both the inner and outer trays, however, Zimmer has decided to recall all manufacturing lots that have not expired and that were sterile packaged in the ZMBV facility Building 1 packaging operations.
- Z-1042-2014 · Class II · terminated · initiated 2013-10-11 · matched through shared submission K112885, may concern other models: Zimmer recently conducted a review of all historic packaging validations at its Zimmer Manufacturing B.V. (ZMBV) facility in Ponce, Puerto Rico. Based on this review, it was determined that the packaging operations conducted in the Building 1 packaging operation at this facility were not properly validated. As a result, Zimmer conducted seal integrity testing to evaluate if previously packaged product from this facility met the established requirements for sterile barrier integrity. The acceptance criteria established for this testing was 99% reliability with a 90% confidence interval. These packaging tray configurations met the acceptance criteria for sterile barrier integrity of both the inner and outer trays, however, Zimmer has decided to recall all manufacturing lots that have not expired and that were sterile packaged in the ZMBV facility Building 1 packaging operations.

## Identity

- Generic name: Orthopaedic bone screw (non-sliding) [FDA GUDID (AccessGUDID)]
- Model / Ref / Catalog: 47-2480-026-41 [FDA GUDID (AccessGUDID)]

## Identifiers

- Primary DI / UDI-DI: 00889024093034 [FDA GUDID (AccessGUDID)]
- 510(k) Number: K112885 [FDA GUDID (AccessGUDID)]
- FDA product code: JDI [FDA GUDID (AccessGUDID)]
- GMDN term: Orthopaedic bone screw (non-sliding) (66947) [FDA GUDID (AccessGUDID)]

## Classification

- Device class: Class II [FDA GUDID (AccessGUDID)]
- Regulation number: 888.3350 [FDA GUDID (AccessGUDID)]
- GUDID distribution status: In Commercial Distribution [FDA GUDID (AccessGUDID)]

## Dimensions & Sizes

- Size: Length — 26 Millimeter [FDA GUDID (AccessGUDID)]

## Properties

- Supplied sterile: Yes [FDA GUDID (AccessGUDID)]
- Single use: Yes [FDA GUDID (AccessGUDID)]
- Implantable: Yes [FDA GUDID (AccessGUDID)]
- Prescription use: Yes [FDA GUDID (AccessGUDID)]
- Lot / batch number: Yes [FDA GUDID (AccessGUDID)]
- Expiration date: Yes [FDA GUDID (AccessGUDID)]
- Sterilise before use: No [FDA GUDID (AccessGUDID)]
- Contains latex: No [FDA GUDID (AccessGUDID)]
- Over-the-counter: No [FDA GUDID (AccessGUDID)]
- Convenience kit: No [FDA GUDID (AccessGUDID)]
- Combination product: No [FDA GUDID (AccessGUDID)]
- HCT/P: No [FDA GUDID (AccessGUDID)]
- Premarket exempt: No [FDA GUDID (AccessGUDID)]
- Serial number: No [FDA GUDID (AccessGUDID)]
- Manufacturing date: No [FDA GUDID (AccessGUDID)]

## Source and citation

- Cite as: 47-2480-026-41, Zimmer, Inc. deviCERTS medical device catalogue. https://devicerts.com/devices/na-47-2480-026-41 (data as of 2026-11-29).
- Data sources: [FDA GUDID (AccessGUDID)](https://accessgudid.nlm.nih.gov/), [FDA recalls](https://open.fda.gov/apis/device/recall/)
- Registry records last synced: 2026-10-23
- Statuses computed as of: 2026-11-29
- JSON: <https://devicerts.com/devices/na-47-2480-026-41.json>
- Licence: [CC BY 4.0](https://creativecommons.org/licenses/by/4.0/). The deviCERTS layout and text are licensed under CC BY 4.0. Registry data remain under their source terms: U.S. FDA data (openFDA, AccessGUDID) are U.S. public domain; EUDAMED data are subject to the European Commission reuse terms.
- Attribution: DevicErts, https://devicerts.com/devices/na-47-2480-026-41
- Compiled by deviCERTS (devicerts.com) from public medical device registries (EUDAMED, European Commission; U.S. FDA via openFDA; AccessGUDID, U.S. National Library of Medicine). deviCERTS is not an official register and gives no regulatory advice: the record in the registry itself prevails.
