66000

by Medtronic, Inc.

66000 is a patient monitoring system module (FDA Class II; FDA product code DXS, Gauge, Pressure, Coronary, Cardiopulmonary Bypass) made by Medtronic, Inc., cleared under FDA 510(k) K852232 on 9 Aug 1985 and listed in FDA GUDID since 28 Apr 2016 (UDI-DI 00643169200999), active as of 22 Oct 2026. 4 FDA recalls are linked to it.

Active United States. Also listed in GUDID (US).

510(k)

Valid until

No expiry

510(k) clearance is not time-limited

FDA recalls

None ongoing

4 closed

Documents

510(k) K852232

FDA submission, from GUDID

Trust

Unverified

Source GUDID, synced 22 Oct 2026.

Regulatory status

as of registry sync 22 Oct 2026

RegionAuthorizationNumberDateStatus
United StatesGUDID listing Number00643169200999 UDI-DI Date28 Apr 2016ListedStatusListed GUDID: in commercial distribution
United StatesFDA 510(k)SESE from GUDID Substantially Equivalent · Traditional NumberK852232 Date9 Aug 1985DecidedStatusActive

Official records

Across registries

2 registries list this device

  • FDA 510(k) K852232 decided 9 Aug 1985 Active
  • FDA GUDID UDI-DI 00643169200999 listed 28 Apr 2016 Listed

Recalls

4 recalls · FDA

    • Terminated Z-2768-2017 FDA Class II initiated 22 Jun 2017

    Identification of small pinholes in a single packaging configuration of sterile pouches. A total of seven different products were affected.

  • 2 recalls, same reason

    • Terminated Z-0079-2012 FDA Unclassified (pre-2012) initiated 9 Sep 2011
    • Terminated Z-0078-2012 FDA Unclassified (pre-2012) initiated 9 Sep 2011

    Pressure Display Set (models 61000, 61006, 62000, 62006) DFU will be updated to clarify that the intended use of the disposables is only for cardiopulmonary bypass surgery (procedures up to 6 hours). Use beyond 6 hours may result in air leakage in the system resulting in a pressure reading that is not representative of the actual line pressure.

    • Terminated Z-0077-2012 FDA Unclassified (pre-2012) initiated 9 Sep 2011

    The DFU for the Medtronic Pressure Display Box, model 66000, states that, for display readings of -100 to +300 mmHg there will be an accuracy of +/-5 mmHg, and for display readings of +301 to +500 mmHg there will be an accuracy of +/-10 mmHg. Through reports from customers, Medtronic has become aware that the Pressure Display Box may not always accurately display readings. During use in the -40

Timeline

6 dated events

  1. Cleared FDA 510(k) K852232
  2. Recall initiated FDA recalls Z-0079-2012
  3. Recall initiated FDA recalls Z-0077-2012
  4. Recall initiated FDA recalls Z-0078-2012
  5. Listed FDA GUDID 00643169200999
  6. Recall initiated FDA recalls Z-2768-2017

Coverage

1 jurisdiction

United States of America
  • Active
  • Expiring
  • Withdrawn
  • Listed
  • Not covered

United States — FDA 510(k) Active

Specification

GUDID

Generic name
Patient monitoring system module, blood pressure, invasive
Model / reference
66000
Primary DI / UDI-DI
00643169200999
510(k) Number
FDA product code
DXS
GMDN term
Patient monitoring system module, blood pressure, invasive
Device class
Class II
Regulation number
870.4310
GUDID distribution status
In Commercial Distribution

Similar devices

Other devices filed under FDA product code DXS (GAUGE, PRESSURE, CORONARY, CARDIOPULMONARY BYPASS).

Other devices from Medtronic, Inc.

See all devices from Medtronic, Inc. →

Properties

  • Serial number
Other properties (14, all answered No)