8309123
Ref 8309.123Model 10000201297
8309123 (8309.123) is a laparoscopic trocar blade (EU MDD Class I; FDA Class II; FDA product code FBQ, Trocar, gastro-urology) made by Richard Wolf GmbH, registered in EUDAMED on 5 Oct 2026 (Basic UDI-DI B-04055207014868) and listed in FDA GUDID since 28 Sep 2016 (UDI-DI 04055207014868), active as of 23 Oct 2026.
Active
CE MDD
Valid until
No date given
FDA recalls
Not checked
Documents
None linked in EUDAMED
Trust
Regulatory status
| Region | Authorization | Number | Date | Status |
|---|---|---|---|---|
| European Union | CE/MDD EUDAMED | NumberB-04055207014868 04055207014868 | Date5 Oct 2026 | StatusActive |
| United States | GUDID listing GUDID | Number04055207014868 | Date28 Sep 2016 | StatusListed |
Official records
- EUDAMED public site B-04055207014868
- AccessGUDID record 04055207014868
From the FDA record
- Device description
- TROCAR TIP TRIANGULAR SZ 2.2MM WL 119MM distal tip triangular, reusable
- MRI safety
- Labeling does not contain MRI Safety Information
- Natural rubber latex
- No latex statement on the label
- Sterility
- Supplied non-sterile; sterilise before use (Moist Heat or Steam Sterilization)
Across registries
- EUDAMED Basic UDI-DI B-04055207014868 registered 5 Oct 2026 Active
- FDA GUDID UDI-DI 04055207014868 listed 28 Sep 2016 Listed
Timeline
- Listed FDA GUDID 04055207014868
- Registered EUDAMED B-04055207014868
Coverage
- Active
- Expiring
- Withdrawn
- Listed
- Not covered
- European Union
- United States
Specification
- Generic name
- Laparoscopic trocar blade, reusable
- Device name
- Surgical trocar tips
- Model / Ref / Catalog
- 10000201297, 8309.123, 8309123
- Description
- TROCAR TIP TRIANGULAR SZ 2.2MM WL 119MM distal tip triangular, reusable
- Primary DI / UDI-DI
- 04055207014868
- Basic UDI-DI
- B-04055207014868
- FDA product code
- FBQ
- EMDN code
- L031299 Surgical trocar, reusable - other
- GMDN term
- Laparoscopic trocar blade, reusable
- Device class
- Class I EUDAMEDClass II GUDID
- Regulation number
- 876.5090
- EU registration type
- Legacy device (under a directive)
- EU market of registration
- Germany
- GUDID distribution status
- In Commercial Distribution
- Sterilisation method
- Moist Heat or Steam Sterilization
- Size
- Length — 119 Millimeter
Truth per registry
| Field | EUDAMED | GUDID |
|---|---|---|
| Model / reference | 10000201297 8309.123 | 8309123 |
| Device class | Class I | Class II |
Similar devices in this category