Na ARD567355901
by Maquet, Inc.
Listed
Valid until
Not applicable
FDA recalls
2 ongoingDocuments
None
Trust
Unverified
Regulatory status
| Region | Authorization | Number | Date | Status |
|---|---|---|---|---|
| United States | GUDID listing | Number03700712404918 | Date16 Sep 2016 | StatusListed |
Recalls
-
- Ongoing Z-0758-2024
A potential for a light system to fall in the operating room.
-
- Ongoing Z-1308-2022
Paint particles may detach and fall in the operating field. In the worst case scenario, infection, organ irritation, hypersensitivity reaction, and tissue granuloma may result if paint particles fall during surgical operation into the patient body or in the operating field.
-
- Terminated Z-1852-2019
- Terminated Z-1853-2019
- Terminated Z-1864-2019
- Terminated Z-1858-2019
- Terminated Z-1855-2019
- Terminated Z-1860-2019
- Terminated Z-1862-2019
- Terminated Z-1856-2019
- Terminated Z-1859-2019
- Terminated Z-1854-2019
- Terminated Z-1863-2019
- Terminated Z-1861-2019
- Terminated Z-1857-2019
Potential that the coating of the light head forks on the VOLISTA Surgical Lights may crack, posing the risk of particles falling into the surgical field during surgery that may result in patient infection
-
- Terminated Z-2502-2018
Certain VOLISTA StandOP Surgical Lights have been identified as having a potential light head detachment issue. Improper assembly of the bracket that connects the light head to the axle fork could result in the light head bracket breaking, causing the light head to detach from the arm and become suspended only from the cabling inside the arm. Use of an affected device may result in serious injury to patient and/or medical staff if the light head detaches and drops, impacting patient and/or medical staff during demonstration, service, or use.
-
- Terminated Z-1937-2018
Potential keypad failure on VOLISTA StandOP Surgical Lights.
-
- Terminated Z-1349-2018
The manufacturer received complaints indicating that the device's central handle holder detaches easily from the handle holder ring on the light head during clinical use. In the event of such detachment, particles from the handle holder ring could fall into the sterile field during a procedure.
-
- Terminated Z-1990-2015
Maquet Suspension Arms used with PowerLED/X-TEN/Volista Surgical Light Systems may grind at the junction of the suspension arms which can cause paint chips or particles to fall into the surgical field, when the suspension arms are mounted above the surgical table.
Coverage
- Active
- Expiring
- Withdrawn
- Listed
- Not covered
United States — GUDID listing Listed
Specification
- Generic Name
- Operating room light
- Model / Reference
- ARD567355901
- Primary DI / UDI-DI
- 03700712404918
- 510(k) Number
- FDA Product Code
- FTD, FSY
- GMDN Term
- Operating room light
- Device Class
- Class II
- Regulation Number
- 878.4580
- GUDID distribution status
- In Commercial Distribution
- MRI Safety
- MR Unsafe
Other devices from Maquet, Inc.
Properties
Other properties (12)
- Sterile: No
- Single Use: No
- Implantable: No
- Contains Latex: No
- Prescription Use: No
- Over-the-Counter: No
- Convenience Kit: No
- Combination Product: No
- HCT/P: No
- Premarket Exempt: No
- Lot / Batch Number: No
- Expiration Date: No