BF091
BF091 is a universal operating table (FDA Class I; FDA product code FQO, Table, Operating-Room, Ac-Powered) made by Steris Corporation, cleared under FDA 510(k) K090136 on 20 Mar 2009 and listed in FDA GUDID since 23 Apr 2021 (UDI-DI 00724995190590), active as of 22 Oct 2026. 2 FDA recalls are linked to it.
Active
Valid until
No expiry
FDA recalls
None ongoingDocuments
Trust
Regulatory status
| Region | Authorization | Number | Date | Status |
|---|---|---|---|---|
| United States | GUDID listing | Number00724995190590 | Date23 Apr 2021 | StatusListed |
| United States | FDA 510(k)SESE | NumberK090136 | Date20 Mar 2009 | StatusActive |
Official records
- AccessGUDID record 00724995190590
- FDA 510(k) database K090136
Across registries
- FDA 510(k) K090136 decided 20 Mar 2009 Active
- FDA GUDID UDI-DI 00724995190590 listed 23 Apr 2021 Listed
Recalls
-
- Terminated Z-0196-2015
The 5085 and 5085SRT stainless steel column shrouds may become damaged as a result of misalignment during extreme table articulation, excessive side force on the table column, or pressure on the base of the table. Severe damage to the shrouds may prevent the user from raising or lowering the surgical table.
-
- Terminated Z-2426-2012
STERIS has learned from Customer feedback and field service experience that damage from external impact to the table hydraulic column can cause the stainless steel shroud sections covering the table hydraulic column to become misaligned; if the damage is severe, the up/down movement of the table may be impeded. In addition, the table hand control may indicate that the table floor locks are unlock
-
- Terminated Z-0279-2012
Some hydraulic column cylinders installed in certain 5085 and 5085SRT Surgical Tables were assembled by their supplier with incorrect snap rings and an anomaly was present in the tilt cylinder. This error may affect the user's ability to move the table top out of the full right tilt position.
-
- Terminated Z-1941-2010
STERIS has learned that a limited quantity of manifold assemblies were manufactured by our supplier with incorrect washers and springs in the valves of the manifold. This supplier error has the potential to cause: a) an inability to articulate/move a table section when commanded by the operator; b) two different articulations occurring when a single articulation is commanded, or c) that the table
Timeline
- Cleared FDA 510(k) K090136
- Recall initiated FDA recalls Z-1941-2010
- Recall initiated FDA recalls Z-0279-2012
- Recall initiated FDA recalls Z-2426-2012
- Recall initiated FDA recalls Z-0196-2015
- Listed FDA GUDID 00724995190590
Coverage
- Active
- Expiring
- Withdrawn
- Listed
- Not covered
United States — FDA 510(k) Active
Specification
- Generic name
- Universal operating table, electromechanical
- Model / Ref / Catalog
- BF091
- Primary DI / UDI-DI
- 00724995190590
- 510(k) Number
- FDA product code
- FQO
- GMDN term
- Universal operating table, electromechanical
- Device class
- Class I
- Regulation number
- 878.4960
- GUDID distribution status
- In Commercial Distribution
Similar devices
Other devices filed under FDA product code FQO (TABLE, OPERATING-ROOM, AC-POWERED).
- Universal Remote Control 1009251 100925B1 by Maquet, Inc.
- 0682400606 0682-400-606 by STRYKER Communications, Inc.
- BYPASS LEG POSITIONER by voss medical products
- TELETOM(R) by Berchtold Holding GmbH
- Universal Remote Control 100925B0 by Maquet, Inc.
- DRAGER DVE 8080/81/82 WITH DVE 4002 OR DVE 4001 SERIES SYSTEM by Alm Surgical Equipment, Inc.
- ENDEX ENDOSCOPIC POSITIONING SYSTEM by Andronic Devices, Ltd.
- Maestro Platform by Moon Surgical, Inc.
- RITTERMODEL 75 EVOLUTION UNIV POW EXAM TABLE/ACCES by Midmark Corporation
- Maestro System (REF100) by Moon Surgical, Inc.