MIC3142
MIC3142, an endoscopic electrosurgical electrode (FDA Class II; FDA product code NUJ) made by Sterilmed, Inc., was cleared under FDA 510(k) K073613 on 12 Feb 2008 and listed in FDA GUDID on 22 Sep 2016 (UDI-DI 10888551001809); the registry lists it as not in commercial distribution (GUDID) as of 23 Oct 2026. FDA recalls on record: 2.
Active
Valid until
No expiry
FDA recalls
None ongoingDocuments
Trust
Regulatory status
| Region | Authorization | Number | Date | Status |
|---|---|---|---|---|
| United States | GUDID listing | Number10888551001809 | Date22 Sep 2016 | StatusListed |
| United States | FDA 510(k)SESE | NumberK073613 | Date12 Feb 2008 | StatusActive |
Official records
- AccessGUDID record 10888551001809
- FDA 510(k) database K073613
From the FDA record
- Device description
- SCISSOR TIP ENDOCUT
- MRI safety
- Labeling does not contain MRI Safety Information
- Natural rubber latex
- No latex statement on the label
- Sterility
- Supplied sterile; sterilise before use (Ethylene Oxide)
Across registries
- FDA 510(k) K073613 decided 12 Feb 2008 Active
- FDA GUDID UDI-DI 10888551001809 listed 22 Sep 2016 Listed
Recalls
-
- Terminated Z-1846-2016
Sterlilmed is recalling all unexpired Scissor Tips because of a potential manufacturing defect that can possibly result in a patient injury.
-
- Terminated Z-0570-2009
SteriMed, Inc is conducting a product removal of a small group of devices individually packaged and sealed within a pouch. The removal is being conducted because the possibility exists that some of the pouches were not properly sealed on one end. A breach in packaging seal or a failure in packaging integrity has the possibility of risk to the patient in terms of transmitting organisms capable
Timeline
- Cleared FDA 510(k) K073613
- Recall initiated FDA recalls Z-0570-2009
- Recall initiated FDA recalls Z-1846-2016
- Listed FDA GUDID 10888551001809
Coverage
- Active
- Expiring
- Withdrawn
- Listed
- Not covered
United States — FDA 510(k) Active
Specification
- Generic name
- Endoscopic electrosurgical electrode, monopolar, single-use
- Model / Ref / Catalog
- MIC3142
- Primary DI / UDI-DI
- 10888551001809
- 510(k) Number
- FDA product code
- NUJ
- GMDN term
- Endoscopic electrosurgical electrode, monopolar, single-use
- Device class
- Class II
- Regulation number
- 878.4400
- GUDID distribution status
- Not in Commercial Distribution
- Sterilisation method
- Ethylene Oxide
Similar devices
Other devices filed under FDA product code NUJ (ELECTROSURGICAL, CUTTING & COAGULATION ACCESSORIES, LAPAROSCOPIC & ENDOSCOPIC, REPROCESSED).
- Reprocessed LigaSure Impact without Nano-coating Large Jaw, Open Sealer/Divider by Stryker Sustainability Solutions
- Reprocessed LigaSure Maryland Jaw Sealer/Divider by Stryker Sustainability Solutions
- NES REPROCESSED VARICOSE VEIN RF CATHETER by NORTHEAST SCIENTIFIC, INC.
- REPROCESSED AUTOSUTURE UNIPOLAR LAPAROSCOPIC/ENDOSCOPIC INSTRUMENTS by Alliance Medical, Inc.
- Medline ReNewal Reprocessed ArthroCare ArthroWands and Smith & Nephew Dyonics by Surgical Instruments Service and Savings, Inc.
- REPROCESSED ELECTROSURGICAL INSTRUMENT by Ascent Healthcare Solutions
- SURETEK REPROCESSED LAPAROSCOPIC INSTRUMENTS by SURETEK MEDICAL
- Vein360 Endovenous Radiofrequency Ablation (RFA) Catheter by Vein 360, LLC
- Reprocessed ArthroCare ENT Coblator by Renovo, Inc.
- Green OR Reprocessed Aquamantys Bipolar Sealer by GREEN OR LLC