Na MP24 R03

by GE Medical Systems, L.L.C.

Listed FDA GUDID listing, not in commercial distribution

Valid until

Not applicable

Database listing, no authorization

FDA recalls

4 ongoing

This device is named in the recall

Documents

None

No authorization documents

Trust

Unverified

Registry data, not yet checked by deviCERTS. Source GUDID, synced 23 Oct 2026. What this means

Regulatory status

as of registry sync 23 Oct 2026

RegionAuthorizationNumberDateStatus
United StatesGUDID listing Number00840682124591 UDI-DI Date29 Nov 2017ListedStatusListed GUDID: not in commercial distribution

Recalls

6 recalls · 4 ongoing · FDA

    • Ongoing Z-2309-2025 FDA Class II initiated 20 Jun 2025 on shared 510(k) K142098

    GE HealthCare has become aware that for certain MR systems (SIGNA Artist, SIGNA Voyager, Discovery MR450 1.5T, Optima MR450w 1.5T, SIGNA Architect, SIGNA Premier, SIGNA UHP, Discovery MR750 3.0T, Discovery MR750w 3.0T, SIGNA Hero, SIGNA PET/MR, SIGNA Artist Evo, SIGNA Voyager AIR (China Only), SIGNA Architect AIR (China Only), SIGNA Premier XT (China Only), SIGNA Premier Elite (China Only), SIGNA Premier MAX (China Only), SIGNA Hero XT (China Only), SIGNA Hero Elite (China Only), SIGNA Hero MAX (China Only), SIGNA PET/MR AIR (China Only), SIGNA PET/MR AIR Plus (China Only), the planned maintenance steps to check the functionality of the caster locks on the MR patient table may not have been performed.

    • Ongoing Z-0520-2025 FDA Class II initiated 28 Oct 2024 on shared 510(k) K142098

    Gradient coils for certain MR systems (see affected product list in this letter), under specific conditions, can produce elevated acoustic noise during scanning.

    • Ongoing Z-2466-2024 FDA Class II initiated 14 Jun 2024

    GE HealthCare has become aware that for certain MR systems, the system predicted B1+RMS value can exceed the B1+RMS user prescribed limit when scanning in Low SAR Mode and the following two conditions are met: 1. 2D FSE T2 FLAIR OR T2 FLAIR Propeller imaging sequence is selected, AND 2. the Optimized T2 FLAIR sequence option is turned off OR not included in the MR configuration. If this occurs, it can result in overheating of an MR conditional implant.

    • Ongoing Z-0595-2022 FDA Class II initiated 23 Dec 2021

    The magnetic resonance systems could potentially have a cryogen ventilation system that does not meet the venting requirements.

    • Terminated Z-3029-2017 FDA Class II initiated 11 May 2017 on shared 510(k) K142098

    Possible incorrect wiring of the Uninterruptable Power Supply, which could contribute to a potential shock hazard.

    • Terminated Z-0260-2016 FDA Class II initiated 31 Aug 2015

    When performing head or neck scans, the currently displayed SAR values could be lower than the actual SAR in the head as predicted by SAR modeling. The predicted HEAD SAR value from the modeling suggests the actual SAR in the head could exceed IEC60601-2-33 limit of 3.2 W/kg for some scans.

Recalls on a shared submission name another device cleared under the same FDA submission as this one.

Coverage

1 jurisdiction

United States of America
  • Active
  • Expiring
  • Withdrawn
  • Listed
  • Not covered

United States — GUDID listing Listed

Specification

GUDID

Generic Name
MRI system application software
Model / Reference
MP24 R03
Primary DI / UDI-DI
00840682124591
510(k) Number
FDA Product Code
OUO
GMDN Term
MRI system application software
Device Class
Class II
Regulation Number
892.1200
GUDID distribution status
Not in Commercial Distribution

Other devices from GE Medical Systems, L.L.C.

See all devices from GE Medical Systems, L.L.C. →

Properties

  • Prescription Use
  • Lot / Batch Number

Other properties (12)

  • Sterile: No
  • Single Use: No
  • Implantable: No
  • Contains Latex: No
  • Over-the-Counter: No
  • Convenience Kit: No
  • Combination Product: No
  • HCT/P: No
  • Premarket Exempt: No
  • Serial Number: No
  • Expiration Date: No
  • Manufacturing Date: No