SDT2.8L46
Part of a family of 640 devices: see the family page
Ref SDT2.8L46
SDT2.8L46 is an orthopaedic bone screw (EU MDR Class IIb; FDA Class II; FDA product code HWC, Screw, Fixation, Bone) made by Newclip Technics, registered in EUDAMED on 15 Jul 2026 (Basic UDI-DI 3700569600088Y), cleared under FDA 510(k) K100944 on 22 Oct 2010 and listed in FDA GUDID since 28 Sep 2016 (UDI-DI 03700569626532), active as of 23 Oct 2026.
Active
CE MDR 510(k)
Valid until
No date given
FDA recalls
None found
Trust
Regulatory status
| Region | Authorization | Number | Date | Status |
|---|---|---|---|---|
| European Union | CE/MDR EUDAMED | Number3700569600088Y 03700569626532 | Date15 Jul 2026 | StatusActive |
| United States | GUDID listing GUDID | Number03700569626532 | Date28 Sep 2016 | StatusListed |
| United States | FDA 510(k)SESE GUDID | NumberK100944 | Date22 Oct 2010 | StatusActive |
Official records
- EUDAMED public site 3700569600088Y
- AccessGUDID record 03700569626532
- FDA 510(k) database K100944
From the FDA record
- MRI safety
- Labeling does not contain MRI Safety Information
- Natural rubber latex
- No latex statement on the label
- Sterility
- Supplied non-sterile; sterilise before use (Moist Heat or Steam Sterilization)
Across registries
- EUDAMED Basic UDI-DI 3700569600088Y registered 15 Jul 2026 Active
- FDA 510(k) K100944 decided 22 Oct 2010 Active
- FDA GUDID UDI-DI 03700569626532 listed 28 Sep 2016 Listed
Timeline
- Cleared FDA 510(k) K100944
- Listed FDA GUDID 03700569626532
- Registered EUDAMED 3700569600088Y
Coverage
- Active
- Expiring
- Withdrawn
- Listed
- Not covered
- European Union
- United States
Specification
- Generic name
- Orthopaedic bone screw, non-bioabsorbable, non-sterile
- Device name
- Screws associated to the plates Alians Clavicle, Alians Elbow, Alians Elbow S, Alians Forearm, Activ Ankle, Initial A, Alians Clavicle S, Initial C
- Model / Ref / Catalog
- SDT2.8L46
- Primary DI / UDI-DI
- 03700569626532
- Basic UDI-DI
- 3700569600088Y
- 510(k) Number
- FDA product code
- HWC
- EMDN code
- P09120602 Cancellous screws
- GMDN term
- Orthopaedic bone screw, non-bioabsorbable, non-sterile
- Device class
- Class IIb EUDAMEDClass II GUDID
- Regulation number
- 888.3040
- EU registration type
- Standard device
- EU market of registration
- France
- GUDID distribution status
- In Commercial Distribution
- Sterilisation method
- Moist Heat or Steam Sterilization
Truth per registry
| Field | EUDAMED | GUDID |
|---|---|---|
| Device class | Class IIb | Class II |
| Implantable | Yes | No |
Similar devices in this category
Other devices filed under CANCELLOUS SCREWS.
- Omni Stable AF 144-28142 by Extremity Medical, LLC
- CANCELLOUS LOCKING SCREW 8161-40-040 816140040 by Biomet Orthopedics, Inc.
- Omni Stable AF 144-35140 by Extremity Medical, LLC
- NON-LOCK SCREW SQUARE DRIVE 131827218 by Biomet Orthopedics, Inc.
- 6,5 MM X 65 MM CANCELLOUS SCREW TITANIUM FULL THREAD TM08916565 by Tulpar Tıbbi Ürünler İthalat İhracat Sanayi ve Ticaret L.T.D Ş.T.İ
- 4.0mm Cancellous Screw, Fully Threaded T52004044 by Tianjin Zhengtian Medical Instrument Co., Ltd.
- 6,5 MM X 55 MM CANCELLOUS SCREW TITANIUM FULL THREAD STERILE TM08926555 by Tulpar Tıbbi Ürünler İthalat İhracat Sanayi ve Ticaret L.T.D Ş.T.İ
- NA SP 4030-55-2 by aap Implantate AG
- Traufix 107.16 by FIXIER SA DE CV
- NA SP 4030-10-2 by aap Implantate AG