SIGNA Prime Elite
by GE Healthcare Tianjin Company Limited
Ref SIGNA Prime Elite
SIGNA Prime Elite is a full-body MRI system (EU MDR Class IIa; FDA Class II) made by GE Healthcare(Tianjin) Company Limited, cleared under FDA 510(k) K250379 on 17 Mar 2025 (1 earlier submission), registered in EUDAMED on 24 Oct 2024 (Basic UDI-DI 08406821BUG004837J) and listed in FDA GUDID since 15 Apr 2025 (UDI-DI 00195278601162), active as of 25 Oct 2026. 2 FDA recalls are linked to it.
Active
Valid until
No date given
FDA recalls
2 ongoingTrust
Regulatory status
| Region | Authorization | Number | Date | Status |
|---|---|---|---|---|
| United States | GUDID listing GUDID | Number00195278601162 | Date15 Apr 2025 | StatusListed |
| United States | FDA 510(k)SESE GUDID | NumberK250379 | Date17 Mar 2025 | StatusActive |
| European Union | CE/MDR EUDAMED | Number08406821BUG004837J 00195278601162 | Date24 Oct 2024 | StatusActive |
| United States | FDA 510(k) 510(k) | NumberK211980 | Date16 Jan 2022 | StatusActive |
Official records
- EUDAMED public site 08406821BUG004837J
- AccessGUDID record 00195278601162
- FDA 510(k) database K250379
- FDA 510(k) database K211980
From the FDA record
- Device description
- SIGNA Prime Elite System Medical Device
- MRI safety
- Labeling does not contain MRI Safety Information
- Natural rubber latex
- No latex statement on the label
- Sterility
- Supplied non-sterile
Across registries
- FDA 510(k) K250379 decided 17 Mar 2025 Active
- EUDAMED Basic UDI-DI 08406821BUG004837J registered 24 Oct 2024 Active
- FDA GUDID UDI-DI 00195278601162 listed 15 Apr 2025 Listed
Recalls
-
- Ongoing Z-2479-2024
GE HealthCare has become aware that for certain MR systems, the system predicted B1+RMS value can exceed the B1+RMS user prescribed limit when scanning in Low SAR Mode and the following two conditions are met: 1. 2D FSE T2 FLAIR OR T2 FLAIR Propeller imaging sequence is selected, AND 2. the Optimized T2 FLAIR sequence option is turned off OR not included in the MR configuration. If this occurs, it can result in overheating of an MR conditional implant.
-
- Ongoing Z-0983-2022
During the de-installation of an MR system magnet, if all rigging and hardware that attach to the magnet for transportation are not properly installed and secured, the magnet may fall, leading to potential injury.
Timeline
- Cleared FDA 510(k) K211980
- Recall initiated FDA recalls Z-0983-2022
- Recall initiated FDA recalls Z-2479-2024
- Registered EUDAMED 08406821BUG004837J
- Cleared FDA 510(k) K250379
- Listed FDA GUDID 00195278601162
Coverage
- Active
- Expiring
- Withdrawn
- Listed
- Not covered
- United States
- European Union
Specification
- Generic name
- Full-body MRI system, superconducting magnet
- Model / reference
- SIGNA Prime Elite
- Primary DI / UDI-DI
- 00195278601162
- Basic UDI-DI
- 08406821BUG004837J
- 510(k) Number
- FDA product code
- LNI, LNH
- EMDN code
- Z11050104 Closed magnet MRI scanners with magnetic field less than or equal to 2t
- GMDN term
- Full-body MRI system, superconducting magnet
- Device class
- Class IIa EUDAMEDClass II GUDID
- Regulation number
- 892.1000
- EU registration type
- Standard device
- EU market of registration
- Türkiye
- GUDID distribution status
- In Commercial Distribution
Truth per registry
| Field | EUDAMED | GUDID |
|---|---|---|
| Device class | Class IIa | Class II |
Manufacturer details
- EUDAMED SRN
- CN-MF-000001725
- Authorised representative
- GE Medical Systems SCS FR-AR-000000344
Similar devices in this category
Other devices filed under CLOSED MAGNET MRI SCANNERS WITH MAGNETIC FIELD LESS THAN OR EQUAL TO 2T.
- Upgrade Marlin 782188 by Philips Medical Systems Nederland B.V.
- Vantage Fortian MRT-1550/WK by CANON INC.
- neo315 by Neoscan Solutions GmbH
- Swoop Portable MR Imaging System 850-11010-02 by Hyperfine, Inc.
- Upgrade Marlin to R5.7 782126 by Philips Medical Systems Nederland B.V.
- TOSHIBA SUPERCONDUCTING MRI SYSTEM Vantage Elan MRT-2020 by CANON INC.
- ECHELON Synergy by FUJIFILM CORPORATION
- Magnetic Resonance Imaging System 2000 by Kuanteng (Liaoning) Medical Devices Co., Ltd.
- Magnetic Resonance Imaging System SuperMark 1.5T by Shenzhen Anke High-Tech Co., Ltd.
- 88000654 by Shanghai United Imaging Healthcare Co., Ltd.
Other devices from GE Healthcare(Tianjin) Company Limited
See all devices from GE Healthcare(Tianjin) Company Limited →