Skip to content

SIGNA Prime Elite

by GE Healthcare Tianjin Company Limited

Ref SIGNA Prime Elite

SIGNA Prime Elite is a full-body MRI system (EU MDR Class IIa; FDA Class II) made by GE Healthcare(Tianjin) Company Limited, cleared under FDA 510(k) K250379 on 17 Mar 2025 (1 earlier submission), registered in EUDAMED on 24 Oct 2024 (Basic UDI-DI 08406821BUG004837J) and listed in FDA GUDID since 15 Apr 2025 (UDI-DI 00195278601162), active as of 25 Oct 2026. 2 FDA recalls are linked to it.

Active European Union and United States. Also listed in GUDID (US).

CE MDR 510(k)

Valid until

No date given

CE: no date in EUDAMED. FDA: not time-limited

FDA recalls

2 ongoing

This device is named in the recall

Documents

None linked in EUDAMED

A group certificate may exist

Trust

Unverified

Source EUDAMED, FDA 510(k), GUDID, synced 25 Oct 2026.

Regulatory status

as of registry sync 25 Oct 2026

RegionAuthorizationNumberDateStatus
United StatesGUDID listing GUDID Number00195278601162 UDI-DI Date15 Apr 2025ListedStatusListed GUDID: in commercial distribution
United StatesFDA 510(k)SESE GUDID from GUDID Substantially Equivalent · Traditional NumberK250379 Date17 Mar 2025DecidedStatusActive
European UnionCE/MDR EUDAMED Number08406821BUG004837J Basic UDI-DI 00195278601162UDI-DIDate24 Oct 2024RegisteredStatusActive
United StatesFDA 510(k) 510(k) NumberK211980 Date16 Jan 2022IssuedStatusActive

Official records

From the FDA record

Device description
SIGNA Prime Elite System Medical Device
MRI safety
Labeling does not contain MRI Safety Information
Natural rubber latex
No latex statement on the label
Sterility
Supplied non-sterile

From the GUDID record (AccessGUDID), as read on 30 May 2026, as the labeller entered it.

Across registries

3 registries list this device

  • FDA 510(k) K250379 decided 17 Mar 2025 Active· +1 more in the status table
  • EUDAMED Basic UDI-DI 08406821BUG004837J registered 24 Oct 2024 Active
  • FDA GUDID UDI-DI 00195278601162 listed 15 Apr 2025 Listed

Recalls

2 recalls · 2 ongoing · FDA

    • Ongoing Z-2479-2024 FDA Class II initiated 14 Jun 2024

    GE HealthCare has become aware that for certain MR systems, the system predicted B1+RMS value can exceed the B1+RMS user prescribed limit when scanning in Low SAR Mode and the following two conditions are met: 1. 2D FSE T2 FLAIR OR T2 FLAIR Propeller imaging sequence is selected, AND 2. the Optimized T2 FLAIR sequence option is turned off OR not included in the MR configuration. If this occurs, it can result in overheating of an MR conditional implant.

    • Ongoing Z-0983-2022 FDA Class II initiated 4 Mar 2022

    During the de-installation of an MR system magnet, if all rigging and hardware that attach to the magnet for transportation are not properly installed and secured, the magnet may fall, leading to potential injury.

Timeline

6 dated events

  1. Cleared FDA 510(k) K211980
  2. Recall initiated FDA recalls Z-0983-2022
  3. Recall initiated FDA recalls Z-2479-2024
  4. Registered EUDAMED 08406821BUG004837J
  5. Cleared FDA 510(k) K250379
  6. Listed FDA GUDID 00195278601162

Coverage

2 jurisdictions

United States of AmericaSwedenFinlandLatviaEstoniaDenmarkLithuaniaIrelandNetherlandsGermanyPolandFranceBelgiumLuxembourgCzech RepublicSlovakiaAustriaHungaryRomaniaSloveniaBulgariaPortugalSpainItalyCroatiaGreeceMaltaCyprus
  • Active
  • Expiring
  • Withdrawn
  • Listed
  • Not covered
  • United States FDA 510(k) Active
  • European Union CE/MDR Active

Specification

EUDAMED · 510(k) · GUDID

Generic name
Full-body MRI system, superconducting magnet
Model / reference
SIGNA Prime Elite
Primary DI / UDI-DI
00195278601162
Basic UDI-DI
08406821BUG004837J
510(k) Number
FDA product code
LNI, LNH
EMDN code
Z11050104 Closed magnet MRI scanners with magnetic field less than or equal to 2t
GMDN term
Full-body MRI system, superconducting magnet
Device class
Class IIa EUDAMED
Class II GUDID
Regulation number
892.1000
EU registration type
Standard device
EU market of registration
Türkiye
GUDID distribution status
In Commercial Distribution

Truth per registry

2 sources · 1 field differs

FieldEUDAMEDGUDID
Device classEUDAMED
Class IIa
GUDID
Class II

Device class is stated on each registry's own scale: Class IIa in the EU (EUDAMED), Class II in the US (FDA GUDID). EU and US classes are different schemes, so this is not a disagreement.

Manufacturer details

EUDAMED SRN
CN-MF-000001725
Authorised representative
GE Medical Systems SCS FR-AR-000000344

Similar devices in this category

Other devices filed under CLOSED MAGNET MRI SCANNERS WITH MAGNETIC FIELD LESS THAN OR EQUAL TO 2T.

Other devices from GE Healthcare(Tianjin) Company Limited

See all devices from GE Healthcare(Tianjin) Company Limited →

Properties

  • Prescription use
  • Serial number
  • Manufacturing date
Other properties (22, all answered No)