Vio-17-3
Vio-17-3, a cranial bur (FDA Class I; FDA product code GFF, Bur, Surgical, General & Plastic Surgery) made by Anspach Effort, The, was cleared under FDA 510(k) K974025 on 6 Jul 1998 and listed in FDA GUDID on 9 Sep 2016 (UDI-DI 00845384010173); the registry lists it as not in commercial distribution (GUDID) as of 23 Oct 2026. FDA recalls on record: 2.
Active
Valid until
No expiry
FDA recalls
None ongoingDocuments
Trust
Regulatory status
| Region | Authorization | Number | Date | Status |
|---|---|---|---|---|
| United States | GUDID listing | Number00845384010173 | Date9 Sep 2016 | StatusListed |
| United States | FDA 510(k)SESE | NumberK974025 | Date6 Jul 1998 | StatusActive |
Official records
- AccessGUDID record 00845384010173
- FDA 510(k) database K974025
From the FDA record
- Device description
- 3 mm Diamond Ball. Use with B-VIOLET Attachment.
- MRI safety
- Labeling does not contain MRI Safety Information
- Natural rubber latex
- No latex statement on the label
- Sterility
- Supplied sterile
Across registries
- FDA 510(k) K974025 decided 6 Jul 1998 Active
- FDA GUDID UDI-DI 00845384010173 listed 9 Sep 2016 Listed
Recalls
-
- Terminated Z-1940-2017
- Terminated Z-1959-2017
- Terminated Z-1960-2017
- Terminated Z-1961-2017
- Terminated Z-1962-2017
- Terminated Z-1966-2017
- Terminated Z-1978-2017
- Terminated Z-1981-2017
- Terminated Z-1982-2017
- Terminated Z-1983-2017
- Terminated Z-1984-2017
- Terminated Z-1989-2017
Supplied Directions for Use (DFU) did not contain a recommended service interval.
-
- Terminated Z-2077-2012
Anspach Effort, Inc. Palm Beach Gardens, FL is recalling their Single Use Sterile Bone Cutting Burrs used with XMax, microMax, microMax Plus, eMax, eMax2 and eMax2 Plus High Speed Drill Systems. It is possible for the cutter to come apart.
-
- Terminated Z-0829-2014
- Terminated Z-0830-2014
Cutter was longer than was stated on the label
-
- Terminated Z-3202-2011
- Terminated Z-3203-2011
The Anspach Effort, Palm Beach Gardens, FL, is recalling their Single Use, Sterile Bone Cutting Burrs, Catalog #, S-1504TD, Lot #s D363039140. D323038110, D293037349 and Catalog # TURQ-434-4, Lot #s D343038845, D323038131, due to the burr being 2.0 mm longer than stated on the label. As a result, a hole drilled using this burr would be 2 mm deeper than the screw.
Timeline
- Recall initiated FDA recalls Z-1960-2017
- Recall initiated FDA recalls Z-1961-2017
- Recall initiated FDA recalls Z-1962-2017
- Recall initiated FDA recalls Z-1966-2017
- Recall initiated FDA recalls Z-1978-2017
- Recall initiated FDA recalls Z-1981-2017
- Recall initiated FDA recalls Z-1982-2017
- Recall initiated FDA recalls Z-1983-2017
- Recall initiated FDA recalls Z-1984-2017
- Recall initiated FDA recalls Z-1989-2017
Coverage
- Active
- Expiring
- Withdrawn
- Listed
- Not covered
United States — FDA 510(k) Active
Specification
- Generic name
- Cranial bur, single-use
- Model / Ref / Catalog
- VIO-17-3
- Primary DI / UDI-DI
- 00845384010173
- 510(k) Number
- FDA product code
- GFF
- GMDN term
- Cranial bur, single-use
- Device class
- Class I
- Regulation number
- 878.4820
- GUDID distribution status
- Not in Commercial Distribution
Similar devices
Other devices filed under FDA product code GFF (BUR, SURGICAL, GENERAL & PLASTIC SURGERY).
- JOTA D2001 by Jota AG
- CONMED 00509322000 5093-220 by Conmed Corporation
- C152.FGL.014 by Jota AG
- CONMED 00505308500 5053-085 by Conmed Corporation
- NSK Sterile Burs/Drills PDS-1RTD110-45 by NAKANISHI INC.
- NSK Sterile Burs/Drills PDS-2RUL-13 by NAKANISHI INC.
- DANEK IRRIGATING BURR (DIB) SET by Danek Medical, Inc.
- SURGICAL BUR by Komet Medical
- BURS FOR MICRO SURGICAL DRILL SYSTEM by ACUMED INSTRUMENTS CORP.
- In2Bones G01 00992 by IN2BONES