XBA2
by Southern Implants (Pty) Ltd
XBA2 is a dental implant suprastructure (FDA Class II; FDA product code NHA, Abutment, Implant, Dental, Endosseous) made by Southern Implants (Pty) Ltd, cleared under FDA 510(k) K163634 on 6 Nov 2017 and listed in FDA GUDID since 17 Jan 2019 (UDI-DI 06009544023661), active as of 22 Oct 2026. One FDA recall is linked to it.
Active
510(k)
Valid until
No expiry
FDA recalls
None ongoingDocuments
Trust
Regulatory status
| Region | Authorization | Number | Date | Status |
|---|---|---|---|---|
| United States | GUDID listing | Number06009544023661 | Date17 Jan 2019 | StatusListed |
| United States | FDA 510(k)SESE | NumberK163634 | Date6 Nov 2017 | StatusActive |
Official records
- AccessGUDID record 06009544023661
- FDA 510(k) database K163634
From the FDA record
- Device description
- Healing Abutment for Ø5.0 Ex Hex, Ø6.5 x 2mm
- MRI safety
- MR Conditional
- Natural rubber latex
- No latex statement on the label
- Sterility
- Supplied sterile
Across registries
- FDA 510(k) K163634 decided 6 Nov 2017 Active
- FDA GUDID UDI-DI 06009544023661 listed 17 Jan 2019 Listed
Recalls
-
- Terminated Z-1386-2018
The UDI label correctly reads IBR12d-13, however, the inner label incorrectly read IBNT12d-13.
Timeline
- Cleared FDA 510(k) K163634
- Recall initiated FDA recalls Z-1386-2018
- Listed FDA GUDID 06009544023661
Coverage
- Active
- Expiring
- Withdrawn
- Listed
- Not covered
United States — FDA 510(k) Active
Specification
- Generic name
- Dental implant suprastructure, temporary, preformed, single-use
- Model / reference
- XBA2
- Primary DI / UDI-DI
- 06009544023661
- 510(k) Number
- FDA product code
- NHA
- GMDN term
- Dental implant suprastructure, temporary, preformed, single-use
- Device class
- Class II
- Regulation number
- 872.3630
- GUDID distribution status
- In Commercial Distribution
- MRI safety
- MR Conditional
Similar devices in this category
Other devices filed under Dental implant suprastructure, temporary, preformed, single-use.
- FRIADENT® 32451641 45-1641 by Dentsply Implants Manufacturing GmbH
- DS Implants 68012239 by Dentsply Implants Manufacturing GmbH
- TMA Impression Coping Open Tray RS5006 by ADIN DENTAL IMPLANT SYSTEMS LTD
- s-Clean Healing Abutment DSH7550 by DENTIS CO., LTD
- Screw Abutment Abutment Analog ASIAM-40 by SNUCONE Co., LTD.
- I-FIX Cemented Abutment DMCAHS by DENTIS CO., LTD
- SI SHAR4070 by Shinhung MST Co., Ltd.
- Paltop 45-70038 by Paltop Advanced Dental Solutions Inc.
- Impression Transfer CO-ITO-4S by OsteoCare Implant System Limited
- Implant Analog 4.5mmD MIH5745 by MEDIGMA BIOMEDICAL GMBH