← Back to catalogue

Nasion Cushion

FDA UDIEUDAMED

Class II (US FDA UDI)

Ref MTHF016Model Stereotactic Radiosurgery and Stereotactic Radiotherapy Devices

by Medtec LLC

Identity

Trade Name
Nasion Cushion FDA UDI
Generic Name
Stereotactic radiosurgical/radiotherapy arch head frame FDA UDI
Device Name
For use with trUpoint ARCH™ FDA UDI
Model / Reference
MTHF016 EUDAMEDFDA UDI
Stereotactic Radiosurgery and Stereotactic Radiotherapy Devices EUDAMED
Description
For use with trUpoint ARCH™ FDA UDI

Identifiers

Catalog Number
MTHF016 FDA UDI
Primary DI / UDI-DI
10841439104221 EUDAMEDFDA UDI
Basic UDI-DI
8414391OC0019R01BX EUDAMED
510(k) Number
K132908 FDA UDI
FDA Product Code
IYE FDA UDI
EMDN Code
Z12011280 PATIENT POSITIONING INSTRUMENTS - HARDWARE ACCESSORIES EUDAMED
GMDN Term
Stereotactic radiosurgical/radiotherapy arch head frame FDA UDI

Classification

Device Class
Class I EUDAMED
Class II FDA UDI
Regulation Number
892.5050 FDA UDI
Market of Registration
Netherlands EUDAMED
Commercial Distribution
In Commercial Distribution FDA UDI

Clinical & Handling

Sterile

No

EUDAMEDFDA UDI

Single Use

No

FDA UDI

Implantable

No

EUDAMEDFDA UDI

Reusable

Yes

EUDAMED

Contains Latex

No

EUDAMEDFDA UDI

Reprocessed

No

EUDAMED

CMR Substance

No

EUDAMED

Human-derived

No

EUDAMED

Human Tissues

No

EUDAMED

Animal Tissues

No

EUDAMED

Endocrine Disruptor

No

EUDAMED

Administering Medicine

No

EUDAMED

Measuring Function

No

EUDAMED

Incorporates Medicinal Product

No

EUDAMED

Prescription Use

Yes

FDA UDI

Over-the-Counter

No

FDA UDI

Convenience Kit

No

FDA UDI

Combination Product

No

FDA UDI

HCT/P

No

FDA UDI

Premarket Exempt

No

FDA UDI

Lot / Batch Number

Yes

FDA UDI

Serial Number

No

FDA UDI

Expiration Date

No

FDA UDI

Manufacturing Date

Yes

FDA UDI
MRI Safety
MR Safe FDA UDI

Category: Stereotactic radiosurgical/radiotherapy arch head frame

Nasion Cushion by Medtec LLC — Class II — MDR, FDA UDI — listed in FDA GUDID, EUDAMED — regulatory data on deviCERTS

Similar devices

Also classified as Stereotactic radiosurgical/radiotherapy arch head frame.

Cleared under the same submission

K132908 also covers:

Authorization Coverage (2 countries)

Regulatory Authorizations

European Union Unknown

MDR

United States Pending data

FDA UDI

Is this your device? Claim it to add documentation and request validation.

Manufacturer

Manufacturer
Medtec LLC

Sources (2)

  • FDA UDI 4038030f-caef-4fa3-bab5-1fba0b5d000e 36 fields · synced Jun 18, 2026