Navitor™
Part of a family of 14 devices: see the family page
Ref NVRO-35Model Navitor Valves; Navitor Titan Valves
Navitor (NVRO-35) is a device of GMDN type aortic transcatheter heart valve bioprosthesis (EU MDR Class III; FDA Class III; FDA product code NPT, Aortic valve, prosthesis, percutaneously delivered) made by Abbott Medical, registered in EUDAMED on 18 Jul 2026 (Basic UDI-DI 5415067TAV1101M8), approved under FDA PMA P190023 on 17 Sep 2021 and listed in FDA GUDID since 5 Nov 2026 (UDI-DI 05415067057341), active as of 16 Nov 2026. 5 FDA recalls are linked to it.
Active
Valid until
15 Aug 2027
FDA recalls
5 ongoingTrust
Regulatory status
| Region | Authorization | Number | Date | Status |
|---|---|---|---|---|
| United States | GUDID listing GUDID | Number05415067057341 | Date5 Nov 2026 | StatusListed |
| European Union | CE/MDR EUDAMED | Number5415067TAV1101M8 05415067057341 | Date18 Jul 2026 | StatusActive |
| United States | FDA PMAAPPR GUDID | NumberP190023 | Date17 Sep 2021 | StatusActive |
Official records
- EUDAMED public site 5415067TAV1101M8
- AccessGUDID record 05415067057341
- FDA PMA database P190023
From the FDA record
- Device description
- Transcatheter Heart Valve
- MRI safety
- MR Conditional
- Natural rubber latex
- No latex statement on the label
- Sterility
- Supplied sterile
Across registries
- EUDAMED Basic UDI-DI 5415067TAV1101M8 registered 18 Jul 2026 Active
- FDA PMA P190023 decided 17 Sep 2021 Active
- FDA GUDID UDI-DI 05415067057341 listed 5 Nov 2026 Listed
Certificates
- MDR 751017 Expiring
Technical documentation EU MDR
- Certifier
- BSI Group The Netherlands B.V. 2797
- Issued
- 27 Aug 2026
- Expires
- 15 Aug 2027
- Reason
- Change approved
Recalls
-
- Ongoing Z-0491-2025
- Ongoing Z-0492-2025
- Ongoing Z-0493-2025
- Ongoing Z-0494-2025
- Ongoing Z-0495-2025
A manufacturing error resulting in acceptance of valves with a leaflet deflection value that was outside of established specifications. This could potentially affect long-term durability of the impacted valve and/or cause potential valve failure.
Timeline
- Approved FDA PMA P190023
- Recall initiated FDA recalls Z-0491-2025
- Recall initiated FDA recalls Z-0492-2025
- Recall initiated FDA recalls Z-0493-2025
- Recall initiated FDA recalls Z-0494-2025
- Recall initiated FDA recalls Z-0495-2025
- Registered EUDAMED 5415067TAV1101M8
- Listed FDA GUDID 05415067057341
Coverage
- Active
- Expiring
- Withdrawn
- Listed
- Not covered
- European Union
- United States
Specification
- Generic name
- Aortic transcatheter heart valve bioprosthesis, stent-like framework
- Device name
- Navitor Family Transcatheter Tissue Valves
- Model / Ref / Catalog
- Navitor Valves, Navitor Titan Valves, NVRO-35
- Primary DI / UDI-DI
- 05415067057341
- Basic UDI-DI
- 5415067TAV1101M8
- PMA number
- FDA product code
- NPT
- EMDN code
- P070301030201 Stented biological aortic valves for percutaneous implant - non-valve tissue of animal origin
- GMDN term
- Aortic transcatheter heart valve bioprosthesis, stent-like framework
- Device class
- Class III
- EU registration type
- Standard device
- EU market of registration
- Belgium
- GUDID distribution status
- In Commercial Distribution
- MRI safety
- MR Conditional
- Size
- Outer Diameter — 35.0000 Millimeter
Manufacturer details
- EUDAMED SRN
- US-MF-000018613
- Authorised representative
- Abbott Medical BE-AR-000008744
Similar devices in this category
Other devices filed under BIOLOGICAL HEART VALVES WITH SUPPORT FOR PERCUTANEOUS IMPLANT - NON-VALVE TISSUE OF ANIMAL ORIGIN.
- ALLEGRA Transcatheter Heart Valve THV-AO0023G1RE by NVT GmbH
- ALLEGRA Transcatheter Heart Valve THV-AO0027G1RE by NVT GmbH
- HYDRA Aortic Valve HYDRA26 by Vascular Innovations Co. Ltd.
- SAPIEN M3 RESILIA Transcatheter Heart Valve 9890RSL29CE by Edwards Lifesciences LLC
- SAPIEN M3 Transcatheter Heart Valve 9880TFX29MCE by Edwards Lifesciences LLC