Needle Guide 11336182 is a needle guide (EU MDR Class IIa; FDA Class II; FDA product code ITX, Transducer, ultrasonic, diagnostic) made by Civco Medical Instruments Co., Inc., registered in EUDAMED on 16 May 2026 (Basic UDI-DI 0841436101TD102A1NC), cleared under FDA 510(k) K970514 on 20 Jun 1997 and listed in FDA GUDID since 3 Sep 2021 (UDI-DI 10841436112052), active as of 23 Oct 2026. 3 FDA recalls are linked to it.

Active European Union and United States. Also listed in GUDID (US).

CE MDR 510(k)

Valid until

No date given

CE: no date in EUDAMED. FDA: not time-limited

FDA recalls

None ongoing

3 closed

Documents

None linked in EUDAMED

A group certificate may exist

510(k) K970514

FDA submission, from GUDID

Trust

Unverified

Source EUDAMED, GUDID, synced 23 Oct 2026.

Regulatory status

as of registry sync 23 Oct 2026

RegionAuthorizationNumberDateStatus
European UnionCE/MDR EUDAMED Number0841436101TD102A1NC Basic UDI-DI 10841436112052UDI-DIDate16 May 2026RegisteredStatusActive
United StatesGUDID listing GUDID Number10841436112052 UDI-DI Date3 Sep 2021ListedStatusListed GUDID: in commercial distribution
United StatesFDA 510(k)SESE GUDID from GUDID Substantially Equivalent · Traditional NumberK970514 Date20 Jun 1997DecidedStatusActive

Official records

From the FDA record

Device description
Disposable sterile endocavity needle guide for use with Siemens BP10-3
MRI safety
Labeling does not contain MRI Safety Information
Natural rubber latex
No latex statement on the label
Sterility
Supplied sterile; sterilise before use (Ethylene Oxide)

From the GUDID record (AccessGUDID), as read on 23 Oct 2026, as the labeller entered it.

Across registries

3 registries list this device

  • EUDAMED Basic UDI-DI 0841436101TD102A1NC registered 16 May 2026 Active
  • FDA 510(k) K970514 decided 20 Jun 1997 Active
  • FDA GUDID UDI-DI 10841436112052 listed 3 Sep 2021 Listed

Recalls

3 recalls · FDA

  • 2 recalls, same reason

    • Terminated Z-2947-2018 FDA Class II initiated 30 Jul 2018
    • Terminated Z-2946-2018 FDA Class II initiated 30 Jul 2018

    The assembly of the needle guides were found to be either missing adhesive or did not have adequate adhesive to hold the assembled cannula in place on the needle guide.

    • Terminated Z-1054-2008 FDA Unclassified (pre-2012) initiated 16 Jan 2008

    Incorrect Needle Guide- The individual pouches contained V53W Endocavity Needle guide(p/n/034-054) instead of the Shimadzu T/R Needle guide (p/n134-054).

Timeline

6 dated events

  1. Cleared FDA 510(k) K970514
  2. Recall initiated FDA recalls Z-1054-2008
  3. Recall initiated FDA recalls Z-2947-2018
  4. Recall initiated FDA recalls Z-2946-2018
  5. Listed FDA GUDID 10841436112052
  6. Registered EUDAMED 0841436101TD102A1NC

Coverage

2 jurisdictions

United States of AmericaSwedenFinlandLatviaEstoniaDenmarkLithuaniaIrelandNetherlandsGermanyPolandFranceBelgiumLuxembourgCzech RepublicSlovakiaAustriaHungaryRomaniaSloveniaBulgariaPortugalSpainItalyCroatiaGreeceMaltaCyprus
  • Active
  • Expiring
  • Withdrawn
  • Listed
  • Not covered
  • European Union CE/MDR Active
  • United States FDA 510(k) Active

Specification

EUDAMED · GUDID

Trade name
Needle Guide
Generic name
Needle guide, single-use
Device name
Endocavity Guidance (Disposable guide)
Model / Ref / Catalog
11336182
Primary DI / UDI-DI
10841436112052
Basic UDI-DI
0841436101TD102A1NC
510(k) Number
FDA product code
ITX
EMDN code
A018002 Needle guides
GMDN term
Needle guide, single-use
Device class
Class IIa EUDAMED
Class II GUDID
Regulation number
892.1570
EU registration type
Standard device
EU market of registration
Germany
GUDID distribution status
In Commercial Distribution
Sterilisation method
Ethylene Oxide
Size
Length — 5.89 Inch
Height — 0.81 Inch

Truth per registry

2 sources · 2 fields differ

FieldEUDAMEDGUDID
Device classEUDAMED
Class IIa
GUDID
Class II
Sterilise before useEUDAMED
No
GUDID
Yes

Registry differences

EUDAMED and FDA GUDID describe the same product (same UDI-DI) and state different values:

  • Sterilise before use UDI-DI 10841436112052: EUDAMED states No, FDA GUDID states Yes.

Device class is stated on each registry's own scale: Class IIa in the EU (EUDAMED), Class II in the US (FDA GUDID). EU and US classes are different schemes, so this is not a disagreement.

Similar devices in this category

Other devices filed under NEEDLE GUIDES.

Other devices from Civco Medical Instruments Co., Inc.

See all devices from Civco Medical Instruments Co., Inc. →

Properties

  • Supplied sterile
  • Sterilise before use NoEUDAMEDYesGUDID
  • Single use
  • Prescription use
  • Convenience kit
  • Lot / batch number
  • Expiration date
  • Manufacturing date
Other properties (17, all answered No)