Needle pusher AL07347000
by Varian Medical Systems Deutschland GmbH
Needle pusher AL07347000 is a general-purpose brachytherapy system applicator (FDA Class II; FDA product code JAQ, System, applicator, radionuclide, remote-controlled) made by Varian Medical Systems Deutschland GmbH, cleared under FDA 510(k) K023220 on 25 Oct 2002 and listed in FDA GUDID since 19 Sep 2016 (UDI-DI 00816389020504), active as of 22 Oct 2026. One FDA recall is linked to it.
Active
Valid until
No expiry
FDA recalls
None ongoingDocuments
Trust
Regulatory status
| Region | Authorization | Number | Date | Status |
|---|---|---|---|---|
| United States | GUDID listing | Number00816389020504 | Date19 Sep 2016 | StatusListed |
| United States | FDA 510(k)SESE | NumberK023220 | Date25 Oct 2002 | StatusActive |
Official records
- AccessGUDID record 00816389020504
- FDA 510(k) database K023220
From the FDA record
- MRI safety
- Labeling does not contain MRI Safety Information
- Natural rubber latex
- No latex statement on the label
- Sterility
- Supplied non-sterile; sterilise before use (Moist Heat or Steam Sterilization)
Across registries
- FDA 510(k) K023220 decided 25 Oct 2002 Active
- FDA GUDID UDI-DI 00816389020504 listed 19 Sep 2016 Listed
Recalls
-
- Terminated Z-0065-2014
The recall was initiated after Varian Medical became aware the Lexan templates of the Breast Bridge Template System could become bent and turn opaque after steam sterilization.
Timeline
- Cleared FDA 510(k) K023220
- Recall initiated FDA recalls Z-0065-2014
- Listed FDA GUDID 00816389020504
Coverage
- Active
- Expiring
- Withdrawn
- Listed
- Not covered
United States — FDA 510(k) Active
Specification
- Trade name
- Needle pusher
- Generic name
- General-purpose brachytherapy system applicator, remote-afterloading
- Model / Ref / Catalog
- AL07347000
- Primary DI / UDI-DI
- 00816389020504
- 510(k) Number
- FDA product code
- JAQ
- GMDN term
- General-purpose brachytherapy system applicator, remote-afterloading
- Device class
- Class II
- Regulation number
- 892.5700
- GUDID distribution status
- In Commercial Distribution
- Sterilisation method
- Moist Heat or Steam Sterilization
Similar devices
Other devices filed under FDA product code JAQ (System, applicator, radionuclide, remote-controlled).
- PROSTATE STEPPER TEMPLATE SET, MODEL PART NUMBER 189, 065, 189, 066, 189, 067 by Nucletron Corp.
- MICROSELECTRON PDR by Nucletron Corp.
- Titanium Flexible Geometry FSD Applicator Set (GM11013400) by Varian Medical Systems, Inc.
- CT/MR Vienna Ring & Tandem Acc Kit, Mick© 2.0mm 0720-2.0 by Mick Radio-Nuclear Instruments, Inc.
- CT/MR M.A.C. Interstitial GYN Template, 1.65mmBebig 1506-1.65 by Mick Radio-Nuclear Instruments, Inc.
- MAMMOSOURCE HIGH DOSE RATE (HDR) REMOTE AFTERLOADER by Varian Medical Systems, Inc.
- GAMMAMED PLUS HIGH DOSE RATE REMOTE AFTERLOADING SYSTEM by Gammamed USA
- PULMOCATH INTRABRONCHIAL CATHETER by Omnitron Intl., Inc.
- Disposable steel needle, 17G, L=200mm 05 LLA210-S by BEBIG Medical GmbH
- SELECTRON HDR REMOTE AFTERLOADER by Nucletron-Oldelft Corp.
Other devices from Varian Medical Systems Deutschland GmbH
See all devices from Varian Medical Systems Deutschland GmbH →