Skip to content

Nellcor PMC10NCH-GE

by Covidien LP

Ref PMC10NCH-GE

Nellcor PMC10NCH-GE is a patient monitoring system module (EU MDR Class IIb; FDA Class II; FDA product code DQA, Oximeter) made by Covidien LP, registered in EUDAMED on 9 Oct 2026 (Basic UDI-DI 0763000B00014347S), cleared under FDA 510(k) K201179 on 20 Jul 2020 and listed in FDA GUDID since 30 Dec 2020 (UDI-DI 10884521780699), active as of 24 Oct 2026.

Active European Union and United States. Also listed in GUDID (US).

CE MDR 510(k)

Valid until

No date given

CE: no date in EUDAMED. FDA: not time-limited

FDA recalls

None found

in data synced 24 Oct 2026

Documents

None linked in EUDAMED

A group certificate may exist

510(k) K201179

FDA submission, from GUDID

Trust

Unverified

Source EUDAMED, GUDID, synced 24 Oct 2026.

Regulatory status

as of registry sync 24 Oct 2026

RegionAuthorizationNumberDateStatus
European UnionCE/MDR EUDAMED Number0763000B00014347S Basic UDI-DI 10884521780699UDI-DIDate9 Oct 2026RegisteredStatusActive
United StatesGUDID listing GUDID Number10884521780699 UDI-DI Date30 Dec 2020ListedStatusListed GUDID: in commercial distribution
United StatesFDA 510(k)SESE GUDID from GUDID Substantially Equivalent · Traditional NumberK201179 Date20 Jul 2020DecidedStatusActive

Official records

From the FDA record

Device description
GE ApexPro (TM) CH SpO2 - Nellcor Cable;For use with GE Patient Monitors.
MRI safety
MR Unsafe
Natural rubber latex
Labelled as not made with natural rubber latex
Sterility
Supplied non-sterile

From the GUDID record (AccessGUDID), as read on 24 Oct 2026, as the labeller entered it.

Across registries

3 registries list this device

  • EUDAMED Basic UDI-DI 0763000B00014347S registered 9 Oct 2026 Active
  • FDA 510(k) K201179 decided 20 Jul 2020 Active
  • FDA GUDID UDI-DI 10884521780699 listed 30 Dec 2020 Listed

Timeline

3 dated events

  1. Cleared FDA 510(k) K201179
  2. Listed FDA GUDID 10884521780699
  3. Registered EUDAMED 0763000B00014347S

Coverage

2 jurisdictions

United States of AmericaSwedenFinlandLatviaEstoniaDenmarkLithuaniaIrelandNetherlandsGermanyPolandFranceBelgiumLuxembourgCzech RepublicSlovakiaAustriaHungaryRomaniaSloveniaBulgariaPortugalSpainItalyCroatiaGreeceMaltaCyprus
  • Active
  • Expiring
  • Withdrawn
  • Listed
  • Not covered
  • European Union CE/MDR Active
  • United States FDA 510(k) Active

Specification

EUDAMED · GUDID

Trade name
Nellcor
Generic name
Patient monitoring system module, pulse oximetry
Device name
PMC10NCH-Ge
Model / reference
PMC10NCH-GE
Primary DI / UDI-DI
10884521780699
Basic UDI-DI
0763000B00014347S
510(k) Number
FDA product code
DQA
EMDN code
Z1203020408 Pulse oximeters
GMDN term
Patient monitoring system module, pulse oximetry
Device class
Class IIb EUDAMED
Class II GUDID
Regulation number
870.2700
EU registration type
Standard device
EU market of registration
Netherlands
GUDID distribution status
In Commercial Distribution
MRI safety
MR Unsafe

Truth per registry

2 sources · 1 field differs

FieldEUDAMEDGUDID
Device classEUDAMED
Class IIb
GUDID
Class II

Device class is stated on each registry's own scale: Class IIb in the EU (EUDAMED), Class II in the US (FDA GUDID). EU and US classes are different schemes, so this is not a disagreement.

Similar devices in this category

Other devices filed under PULSE OXIMETERS.

Other devices from Covidien LP

  • Invos PM7100

    Class II
  • Invos PMAC71DOC Open recall

    Class II
  • LigaSure MRASILF19

    Class II
  • Shiley 110860

    Class II

See all devices from Covidien LP →

Properties

  • Measuring function
  • Prescription use
  • Serial number
  • Manufacturing date
Other properties (21, all answered No)