Neo-Tee
by Mercury Medical Enterprises, LLC 35 variants
Part of a family of 38 devices: see the family page
Ref 10-50823
Neo-Tee (10-50823) is a pulmonary resuscitator (EU MDR Class IIa; FDA Class II; FDA product code BTL, Ventilator, Emergency, Powered (Resuscitator)) made by Mercury Medical Enterprises, LLC, registered in EUDAMED on 24 Jan 2024 (Basic UDI-DI 0641043NEN6), cleared under FDA 510(k) K093913 on 6 Apr 2010 and listed in FDA GUDID since 24 Sep 2015 (UDI-DI 10641043508237), active as of 22 Oct 2026. 3 FDA recalls are linked to it.
Active
Valid until
No date given
FDA recalls
2 ongoingTrust
Regulatory status
| Region | Authorization | Number | Date | Status |
|---|---|---|---|---|
| European Union | CE/MDR EUDAMED | Number0641043NEN6 10641043508237 | Date24 Jan 2024 | StatusActive |
| United States | GUDID listing GUDID | Number10641043508237 | Date24 Sep 2015 | StatusListed |
| United States | FDA 510(k)SESE GUDID | NumberK093913 | Date6 Apr 2010 | StatusActive |
Official records
- EUDAMED public site 0641043NEN6
- AccessGUDID record 10641043508237
- FDA 510(k) database K093913
From the FDA record
- MRI safety
- Labeling does not contain MRI Safety Information
- Natural rubber latex
- Labelled as not made with natural rubber latex
- Sterility
- Supplied non-sterile
Across registries
- EUDAMED Basic UDI-DI 0641043NEN6 registered 24 Jan 2024 Active
- FDA 510(k) K093913 decided 6 Apr 2010 Active
- FDA GUDID UDI-DI 10641043508237 listed 24 Sep 2015 Listed
Recalls
-
- Ongoing Z-0821-2025
Gas powered emergency resuscitator has a circuit flow controller manufactured with an undersized spring, which may cause resuscitator not reach the high and low ends of the PIP and PEEP pressure ranges, which may cause a loss of positive pressure, impacting effective ventilation of the patient.
-
- Ongoing Z-0004-2025
Manual resuscitator circuit flow controller may come apart due to a missing manufacturing step.
-
- Terminated Z-0639-2016
Incorrect use of T-Piece resuscitators will result in complete occlusion of the patient circuit and consequent failure to ventilate the patient.
Timeline
- Cleared FDA 510(k) K093913
- Listed FDA GUDID 10641043508237
- Recall initiated FDA recalls Z-0639-2016
- Registered EUDAMED 0641043NEN6
- Recall initiated FDA recalls Z-0004-2025
- Recall initiated FDA recalls Z-0821-2025
Coverage
- Active
- Expiring
- Withdrawn
- Listed
- Not covered
- European Union
- United States
Specification
- Trade name
- Neo-Tee EUDAMEDNeo-Tee T-Piece Resuscitator GUDID
- Generic name
- Pulmonary resuscitator, manual, single-use
- Model / reference
- 10-50823
- Primary DI / UDI-DI
- 10641043508237
- Basic UDI-DI
- 0641043NEN6
- 510(k) Number
- FDA product code
- BTL
- EMDN code
- R03020201 Manually operated pulmonary resuscitators
- GMDN term
- Pulmonary resuscitator, manual, single-use
- Device class
- Class IIa EUDAMEDClass II GUDID
- Regulation number
- 868.5925
- EU registration type
- Standard device
- EU market of registration
- Netherlands
- GUDID distribution status
- In Commercial Distribution
Truth per registry
| Field | EUDAMED | GUDID |
|---|---|---|
| Device class | Class IIa | Class II |
Manufacturer details
- EUDAMED SRN
- US-MF-000002015
- Authorised representative
- Emergo Europe B.V. NL-AR-000000116
Similar devices in this category
Other devices filed under MANUALLY OPERATED PULMONARY RESUSCITATORS.
- Operah Plus nice 5000 RP by nice Neotech Medical Systems Pvt. Ltd.,
- Ambu® Mark IV 304004000 by Ambu A/S
- Reusable Resuscitator 1700 ml, Adult RE-23150 by BESMED HEALTH BUSINESS CORP.
- Pocket BVM™ Manual Resuscitator Tactical by Micro BVM Systems Ltd
- Manual Resuscitator TVRPOOO by Henan Tuoren Medical Device Co., Ltd.
- Silicone Small Adult Resuscitator 1000 ml W/ 60 cmH2O POP-OFF RE-23142 by BESMED HEALTH BUSINESS CORP.
- PVC Manual Resuscitator EMR0401035 by XIAMEN COMPOWER MEDICAL TECH. CO., LTD.
- The BAG II Resuscitator Infant w/mask #1 845131 by Laerdal Medical AS
- NeoNatalie Resuscitator 846040 by Laerdal Medical AS
- Hanwell by Ningbo Hanyue Medical Technology CO.,LTD.