Neodent 118.330
by JJGC Indústria e Comércio de Materiais Dentários S/A.
Part of a family of 41 devices: see the family page
Ref 118.330Model Abutment
Neodent 118.330 is a dental implant suprastructure (EU MDR Class IIa; FDA Class II; FDA product code NHA, Abutment, implant, dental, endosseous) made by JJGC Indústria e Comércio de Materiais Dentários S/A., registered in EUDAMED on 6 May 2026 (Basic UDI-DI 987800086W3), cleared under FDA 510(k) K163194 on 14 Jul 2017 and listed in FDA GUDID since 10 Aug 2023 (UDI-DI 07899878028857), active as of 7 Nov 2026. One FDA recall is linked to it.
Active
Valid until
No date given
FDA recalls
4 ongoingTrust
Regulatory status
| Region | Authorization | Number | Date | Status |
|---|---|---|---|---|
| European Union | CE/MDR EUDAMED | Number987800086W3 07899878028857 | Date6 May 2026 | StatusActive |
| United States | GUDID listing GUDID | Number07899878028857 | Date10 Aug 2023 | StatusListed |
| United States | FDA 510(k)SESE GUDID | NumberK163194 | Date14 Jul 2017 | StatusActive |
Official records
- EUDAMED public site 987800086W3
- AccessGUDID record 07899878028857
- FDA 510(k) database K163194
From the FDA record
- Device description
- NEO MINI CONICAL ABUTMENT ONE STEP HYBRID COPING
- MRI safety
- MR Conditional
- Natural rubber latex
- No latex statement on the label
- Sterility
- Supplied non-sterile
Across registries
- EUDAMED Basic UDI-DI 987800086W3 registered 6 May 2026 Active
- FDA 510(k) K163194 decided 14 Jul 2017 Active
- FDA GUDID UDI-DI 07899878028857 listed 10 Aug 2023 Listed
Recalls
-
- Ongoing Z-3173-2026
There is a discrepancy between the product identification on the packaging and the dimensions of the implant contained inside.
-
- Ongoing Z-2929-2026
There may be a mismatch between the implant contained inside the packaging and the information described on the outer carton label. If the the incorrect implant is installed, the issue could cause bone compression or difficulty during installation in situations where there is sufficient bone volume
-
- Ongoing Z-1862-2025
- Ongoing Z-1863-2025
It is possible that a package labelled as an 11.5 mm implant may contain a 13 mm implant instead.
-
- Terminated Z-0203-2022
3.5x11.5mm implants were mislabeled as 3.5x10mm implants. In borderline cases where the bone quality is low and the bone ridge has a maximum indication for the implant height (10mm), if the incorrect implant is installed, it could result in damage to the nerve or adjacent bone structures/cavities.
-
- Terminated Z-0455-2019
Laser engraved label does not match with the item in the package
Timeline
- Cleared FDA 510(k) K163194
- Recall initiated FDA recalls Z-0455-2019
- Recall initiated FDA recalls Z-0203-2022
- Listed FDA GUDID 07899878028857
- Recall initiated FDA recalls Z-1862-2025
- Recall initiated FDA recalls Z-1863-2025
- Registered EUDAMED 987800086W3
- Recall initiated FDA recalls Z-2929-2026
- Recall initiated FDA recalls Z-3173-2026
Coverage
- Active
- Expiring
- Withdrawn
- Listed
- Not covered
- European Union
- United States
Specification
- Trade name
- Neodent
- Generic name
- Dental implant suprastructure, permanent, preformed
- Device name
- Permanent Abutments over Abutments
- Model / Ref / Catalog
- 118.330, Abutment
- Primary DI / UDI-DI
- 07899878028857
- Basic UDI-DI
- 987800086W3
- FDA product code
- NHA
- EMDN code
- P01020180 Dental implants - accessories
- GMDN term
- Dental implant suprastructure, permanent, preformed
- Device class
- Class IIa EUDAMEDClass II GUDID
- Regulation number
- 872.3630
- EU registration type
- Standard device
- EU market of registration
- Germany
- GUDID distribution status
- In Commercial Distribution
- MRI safety
- MR Conditional
- Size
- Outer Diameter — 4.1 Millimeter
Truth per registry
| Field | EUDAMED | GUDID |
|---|---|---|
| Device class | Class IIa | Class II |
| Sterilise before use | Yes | No |
| Implantable | No | Yes |
Registry differences
EUDAMED and FDA GUDID describe the same product (same UDI-DI) and state different values:
- Sterilise before use UDI-DI 07899878028857: EUDAMED states Yes, FDA GUDID states No.
Device class is stated on each registry's own scale: Class IIa in the EU (EUDAMED), Class II in the US (FDA GUDID). EU and US classes are different schemes, so this is not a disagreement.
Similar devices in this category
Other devices filed under DENTAL IMPLANTS - ACCESSORIES.
- i-system Non- Shouldered Abutment I-SNSA1050(2.5) by Novodent SA
- enigmalife ELT:C3:L7K by Davis Schottlander & Davis Ltd
- D32172 by S.G.S. International Kft
- Enigma EA:D2:O36 by Davis Schottlander & Davis Ltd
- XiVE® 26-1148 by Dentsply Implants Manufacturing GmbH
- Enigma Denture Teeth - Pairs ET:C1:K41K by DAVIS SCHOTTLANDER & DAVIS LIMITED
- Healing Cap NM-H4605 by NORIS MEDICAL LTD
- Enigma Anterior Denture Teeth EA:D2:O54 by DAVIS SCHOTTLANDER & DAVIS LIMITED
- i-LiNQ Cement Healing Cap I-SILCEHC50 by Novodent SA
- Paltop 40-70064 by Paltop Advanced Dental Solutions Inc.
Other devices from JJGC Indústria e Comércio de Materiais Dentários S/A.
See all devices from JJGC Indústria e Comércio de Materiais Dentários S/A. →