Neogen Handpiece Blk
Ref 830-009
Neogen Handpiece Blk (830-009) is a nitrogen plasma skin surface treatment system (EU MDR Class IIb; EU MDR Class I; FDA Class II; FDA product code GEI, Electrosurgical, Cutting & Coagulation & Accessories) made by Energist, Ltd., cleared under FDA 510(k) K221873 on 12 Jan 2023 (1 earlier submission), registered in EUDAMED on 7 Apr 2022 (Basic UDI-DI B-05060440520105) and listed in FDA GUDID since 13 May 2021 (UDI-DI 05060440520105), active as of 23 Oct 2026.
Active
CE MDR CE MDD 510(k)
Valid until
No date given
FDA recalls
None found
Trust
Regulatory status
| Region | Authorization | Number | Date | Status |
|---|---|---|---|---|
| United States | FDA 510(k)SESE GUDID | NumberK221873 | Date12 Jan 2023 | StatusActive |
| European Union | CE/MDR EUDAMED | NumberB-05060440520105 05060440520105 | Date7 Apr 2022 | StatusActive |
| European Union | CE/MDD EUDAMED | NumberB-05060440520105 05060440520105 | Date7 Apr 2022 | StatusActive |
| United States | GUDID listing GUDID | Number05060440520105 | Date13 May 2021 | StatusListed |
Official records
- EUDAMED public site B-05060440520105
- AccessGUDID record 05060440520105
- FDA 510(k) database K221873
- FDA 510(k) database K132754
Across registries
- FDA 510(k) K221873 decided 12 Jan 2023 Active
- EUDAMED Basic UDI-DI B-05060440520105 registered 7 Apr 2022 Active
- FDA GUDID UDI-DI 05060440520105 listed 13 May 2021 Listed
Timeline
- Cleared FDA 510(k) K132754
- Listed FDA GUDID 05060440520105
- Registered EUDAMED B-05060440520105
- Cleared FDA 510(k) K221873
Coverage
- Active
- Expiring
- Withdrawn
- Listed
- Not covered
- European Union
- United States
Specification
- Trade name
- Neogen
- Generic name
- Nitrogen plasma skin surface treatment system
- Device name
- NeoGen PSR Handpiece BlackNeoGen Handpiece
- Model / Ref / Catalog
- 830-009, Handpiece Blk
- Primary DI / UDI-DI
- 05060440520105
- Basic UDI-DI
- B-05060440520105, 506044052NeoGen-NA-001GM
- Direct marketing DI
- 05060440520105
- FDA product code
- GEI
- EMDN code
- Z12040203 Dermal regeneration equipment
- GMDN term
- Nitrogen plasma skin surface treatment system
- Device class
- Class IIb EUDAMEDClass I EUDAMEDClass II GUDID
- Regulation number
- 878.4400
- EU registration type
- Legacy device (under a directive)Standard device
- EU market of registration
- FranceNetherlands
- GUDID distribution status
- In Commercial Distribution
Truth per registry
| Field | EUDAMED | GUDID |
|---|---|---|
| Model / reference | 830-009 | Handpiece Blk |
| Device class | Class IIb Class I | Class II |
Similar devices in this category
Other devices filed under DERMAL REGENERATION EQUIPMENT.
- S-590 FS90013 by FORMATK SYSTEMS LTD
- DEEP ACTION 30MM A465AE by Termosalud, S.L.
- S-530 FS90012 by FORMATK SYSTEMS LTD
- Tixel C MSTX0002 by NOVOXEL LTD
- B.Light Clear Evo 434500 by Bemer Int. AG
- ARTEMIS 380800000333 by NOVAVISION GROUP
- ZIONIC PRO MAX M105/1 by Termosalud, S.L.
- DAFNE 380800000327 by NOVAVISION GROUP
- Tixel Periorbital Handpiece MPH00001 by NOVOXEL LTD
- CELLIMPACT 27100.0100 by Storz Medical AG