Nerve Locator/Stimulator

by Aaron Medical Industries

510(k) K905045

Active United States

510(k)

Valid until

No expiry

510(k) clearance is not time-limited

FDA recalls

None found

in data synced 22 Oct 2026

Documents

Trust

Unverified

Registry data, not yet checked by deviCERTS. Source FDA 510(k), synced 22 Oct 2026. What this means

Regulatory status

as of registry sync 22 Oct 2026

RegionAuthorizationNumberDateStatus
United StatesFDA 510(k)SESE Substantially Equivalent · Traditional NumberK905045 Date15 Mar 1991ClearedStatusActive

Recalls

0 recalls · FDA

No FDA recalls found in the data synced 22 Oct 2026.

Coverage

1 jurisdiction

United States of America
  • Active
  • Expiring
  • Withdrawn
  • Listed
  • Not covered

United States — FDA 510(k) Active

Specification

510(k)

510(k) Number
FDA Product Code
ETN
Device Class
Class II
Regulation
21 CFR Part 874.1820
Advisory Committee
Ear, Nose, Throat
FDA Decision
SESE Substantially Equivalent

Overview

AI-generated summary, 19 Sep 2026

Written by a language model from registry data. Not verified by deviCERTS or the manufacturer. The registry data above is the record.

This device is a nerve stimulator, designed to locate and identify exposed motor nerves during surgical procedures. It delivers controlled electrical stimulation to facilitate nerve identification while minimizing the risk of accidental damage or severance.

The Nerve Locator/Stimulator is intended for use in clinical settings, such as operating rooms, and is classified as a Class II medical device under FDA regulations (product code ETN). It is reusable and requires proper sterilization between uses. The device was granted FDA 510(k) clearance in 1991 and is regulated under the regulation number 874.1820. No specific MRI safety information is provided in the available data.

Other devices from Aaron Medical Industries

See all devices from Aaron Medical Industries →

Questions

AI-generated answers, 19 Sep 2026

Written by a language model from registry data. Not verified by deviCERTS or the manufacturer. The registry data above is the record.

  • How is the Nerve Locator/Stimulator intended to be used in surgical settings, and what type of nerves does it target?

    The Nerve Locator/Stimulator is designed to locate and identify exposed motor nerves during surgical procedures, such as those in the ear, nose, and throat (ENT) region. It delivers controlled electrical stimulation to help surgeons pinpoint nerves safely, reducing the risk of accidental damage or severance. This is particularly useful in delicate procedures where nerve identification is critical.

  • Is the Nerve Locator/Stimulator single-use or reusable, and what sterilization process is required?

    The device is reusable and must undergo proper sterilization between uses to maintain safety and functionality. Since it is classified as a reusable Class II medical device, adherence to validated sterilization protocols (e.g., autoclave, ethylene oxide, or other approved methods) is essential to prevent cross-contamination and ensure reliable performance.

  • What regulatory pathway was followed for FDA clearance of this device, and when was it originally approved?

    The Nerve Locator/Stimulator received FDA 510(k) clearance under the Traditional pathway in March 1991, with the submission filed on November 8, 1990. It was determined to be *substantially equivalent* to a predicate device and is regulated under 21 CFR 874.1820, falling under the product code ETN (Electrical Stimulators, Nerve).

  • Are there any known limitations regarding MRI compatibility for this device?

    The available data does not provide specific MRI safety information for the Nerve Locator/Stimulator. Clinicians should exercise caution when using or storing the device near MRI equipment, as ferromagnetic components or electrical stimulation could pose risks in magnetic fields. Always verify compatibility with your facility’s MRI protocols before use.