Neuroform Atlas Stent System
PMA P180031
Active
Valid until
No expiry
FDA recalls
None foundDocuments
Trust
Unverified
Regulatory status
| Region | Authorization | Number | Date | Status |
|---|---|---|---|---|
| United States | FDA PMAAPPR | NumberP180031 | Date16 May 2019 | StatusActive |
Recalls
No FDA recalls found in the data synced 6 Oct 2026.
Coverage
- Active
- Expiring
- Withdrawn
- Listed
- Not covered
United States — FDA PMA Active
Specification
- Generic Name
- Intracranial coil-assist stent
- PMA Number
- FDA Product Code
- QCA
- Device Class
- Class III
- Advisory Committee
- Neurology
- FDA Decision
- APPR Approved
Overview
AI-generated summary, 18 Sep 2026
The Neuroform Atlas Stent System is an intracranial coil-assist stent, classified as a Class III medical device under FDA regulations. It is designed to assist in the embolization of wide-necked intracranial aneurysms in the anterior circulation, supporting endovascular treatment for patients aged 18 and older. The device is intended for use in aneurysms with a neck width of 4 mm or greater, or a dome-to-neck ratio of less than 2, arising from parent vessels between 2.0 mm and 4.5 mm in diameter.
This stent system is supplied as a sterile, single-use device and is intended for use in neurovascular procedures. It is regulated under an FDA Premarket Approval (PMA) application (P180031) and is compatible with neurovascular embolization coils. Storage and handling must adhere to sterile medical device protocols, and its use is restricted to qualified neurointerventionalists in clinical settings equipped for endovascular procedures.
Other devices from Stryker Neurovascular
Questions
AI-generated answers, 18 Sep 2026
What types of intracranial aneurysms is the Neuroform Atlas® Stent System designed to assist with during embolization procedures?
The Neuroform Atlas® Stent System is specifically designed to assist in the embolization of wide-necked intracranial aneurysms in the anterior circulation. It is intended for aneurysms with a neck width of 4 mm or greater, or a dome-to-neck ratio of less than 2, arising from parent vessels between 2.0 mm and 4.5 mm in diameter. This makes it suitable for complex cases where traditional coiling alone may be challenging.
Is the Neuroform Atlas® Stent System intended for use in patients of all ages, or is there an age restriction?
The Neuroform Atlas® Stent System is intended for use in patients aged 18 years and older. The device is not approved for pediatric or adolescent patients under the age of 18, as its design and regulatory approval are tailored to the adult neurovascular anatomy and clinical needs.
How is the Neuroform Atlas® Stent System supplied, and what considerations should be made for its storage and handling?
The Neuroform Atlas® Stent System is supplied as a sterile, single-use device, meaning it is intended for one-time use per procedure. Storage and handling must follow standard sterile medical device protocols to maintain its integrity. Since it is designed for neurovascular procedures, it should be stored in a controlled environment, protected from contamination, and used only in clinical settings equipped for endovascular treatments.
What compatibility requirements exist for the Neuroform Atlas® Stent System with other medical devices during embolization?
The Neuroform Atlas® Stent System is explicitly designed to be compatible with neurovascular embolization coils. This compatibility ensures that the stent can assist in the placement and stability of coils within the aneurysm during the embolization procedure, improving the likelihood of successful treatment for wide-necked aneurysms in the anterior circulation.
What regulatory pathway was followed for the approval of the Neuroform Atlas® Stent System, and what does this mean for its use?
The Neuroform Atlas® Stent System underwent a Premarket Approval (PMA) process through the FDA, which is the most stringent regulatory pathway for Class III medical devices. This approval indicates that the device has been thoroughly evaluated for safety and effectiveness in its intended use—assisting in the embolization of wide-necked intracranial aneurysms in the anterior circulation. Its use is restricted to qualified neurointerventionalists in clinical settings equipped for endovascular procedures, ensuring proper training and infrastructure are in place.