Identity
- Trade Name
- NEUROMARK™ Device FDA UDI
- Generic Name
- Electrosurgical system FDA UDI
- Device Name
- The NEUROMARK System is intended for the application of radiofrequency (RF) energy to create lesions in mucosal tissue in otolaryngology [also known as Ear, Nose and Throat (ENT)] procedures in patients with chronic rhinitis. The NEUROMARK System is indicated for use in otorhinolaryngology (ENT) surgery for creation of radiofrequency (RF) lesions to disrupt posterior nasal nerves in patients with chronic rhinitis. The NEUROMARK Device is a hand-held single-use bipolar radiofrequency device which comprises a handle, shaft, and treatment tip. The treatment tip, which is referred to as the End Effector, consists of an array of bipolar micro electrodes. These electrodes deliver bipolar radiofrequency energy while monitoring feedback on the tissue bio-impedance changes allowing for controlled radiofrequency energy level delivery. The NEUROMARK™ Device is operated via handle, slider and activation switch. The NEUROMARK Device is designed for use with the NEUROMARK Radiofrequency Generator. The NEUROMARK Device includes features to allow compatibility and authentication once connected, via a flexible cable, to the NEUROMARK Radiofrequency Generator. FDA UDI
- Model / Reference
- FS-002 FDA UDI
- Description
- The NEUROMARK System is intended for the application of radiofrequency (RF) energy to create lesions in mucosal tissue in otolaryngology [also known as Ear, Nose and Throat (ENT)] procedures in patients with chronic rhinitis. The NEUROMARK System is indicated for use in otorhinolaryngology (ENT) surgery for creation of radiofrequency (RF) lesions to disrupt posterior nasal nerves in patients with chronic rhinitis. The NEUROMARK Device is a hand-held single-use bipolar radiofrequency device which comprises a handle, shaft, and treatment tip. The treatment tip, which is referred to as the End Effector, consists of an array of bipolar micro electrodes. These electrodes deliver bipolar radiofrequency energy while monitoring feedback on the tissue bio-impedance changes allowing for controlled radiofrequency energy level delivery. The NEUROMARK™ Device is operated via handle, slider and activation switch. The NEUROMARK Device is designed for use with the NEUROMARK Radiofrequency Generator. The NEUROMARK Device includes features to allow compatibility and authentication once connected, via a flexible cable, to the NEUROMARK Radiofrequency Generator. FDA UDI
Identifiers
- Primary DI / UDI-DI
- 05391537940002 FDA UDI
- 510(k) Number
- K212666 FDA UDI
- FDA Product Code
- GEI FDA UDI
- GMDN Term
- Electrosurgical system FDA UDI
Classification
- Device Class
- Class II FDA UDI
- Regulation Number
- 878.4400 FDA UDI
- Commercial Distribution
- Not in Commercial Distribution FDA UDI
Clinical & Handling
Sterile
Yes
FDA UDI
Single Use
Yes
FDA UDI
Implantable
No
FDA UDI
Contains Latex
No
FDA UDI
Prescription Use
Yes
FDA UDI
Over-the-Counter
No
FDA UDI
Convenience Kit
No
FDA UDI
Combination Product
No
FDA UDI
HCT/P
No
FDA UDI
Premarket Exempt
No
FDA UDI
Lot / Batch Number
Yes
FDA UDI
Serial Number
No
FDA UDI
Expiration Date
Yes
FDA UDI
Manufacturing Date
Yes
FDA UDI
NEUROMARK™ Device by Neurent Medical — Class II — FDA UDI — listed in FDA GUDID — regulatory data on deviCERTS
Authorization Coverage (1 country)
Regulatory Authorizations
United States Pending data
FDA UDI
| Source | Region | Type | Cert / Approval No. | Class | Status |
|---|---|---|---|---|---|
| FDA UDI | United States | FDA UDI | Registered in GUDID | Class II | Pending data |
Is this your device? Claim it to add documentation and request validation.
Manufacturer
- Manufacturer
- Neurent Medical
Sources (1)
- FDA UDI bc6a575b-7f9a-4f28-bbfe-59abd204a5b4 35 fields · synced May 30, 2026