Polyurethane Tubing for Permanent Pacemaker Electrode
by Telectronics Pacing Systems, Inc.
510(k) K914489
Active
Valid until
No expiry
FDA recalls
None foundDocuments
Trust
Unverified
Regulatory status
| Region | Authorization | Number | Date | Status |
|---|---|---|---|---|
| United States | FDA 510(k)SESE | NumberK914489 | Date17 Aug 1992 | StatusActive |
Recalls
No FDA recalls found in the data synced 22 Oct 2026.
Coverage
- Active
- Expiring
- Withdrawn
- Listed
- Not covered
United States — FDA 510(k) Active
Specification
- Full name
- New Extrusion Vendor for Polyurethane Tubing
- 510(k) Number
- FDA Product Code
- DTB
- Device Class
- Class III
- Regulation
- 21 CFR Part 870.3680
- Advisory Committee
- Cardiovascular
- FDA Decision
- SESE Substantially Equivalent
Overview
AI-generated summary, 20 Sep 2026
This device is a Permanent Pacemaker Electrode component, specifically polyurethane tubing designed for use in cardiac pacing systems. The tubing serves as an insulating and protective layer for electrical leads, ensuring durability and flexibility for long-term implantation within the body. Its construction supports the structural integrity of pacemaker leads while maintaining biocompatibility and electrical isolation.
The tubing is supplied as a reusable component in the manufacturing process of pacemaker electrodes, adhering to FDA 510(k) clearance (K914489) under 21 CFR 870.3680. It is intended for use in Class III medical devices, regulated under strict quality and safety standards. No information regarding sterility, single-use, or MRI safety is provided in the specifications, though it is manufactured for compliance with Telectronics Pacing Systems, Inc.’s production requirements.
Other devices from Telectronics Pacing Systems, Inc.
Questions
AI-generated answers, 20 Sep 2026
What is the primary purpose of this polyurethane tubing in cardiac pacing systems?
This polyurethane tubing serves as an insulating and protective layer for electrical leads in permanent pacemaker systems. Its design ensures durability and flexibility, which are critical for long-term implantation within the body while maintaining electrical isolation and structural integrity of the lead.
Is this tubing intended for direct patient implantation, or is it used in manufacturing?
The tubing is not intended for direct patient implantation. Instead, it is supplied as a reusable component in the manufacturing process of pacemaker electrodes, ensuring the leads meet quality and safety standards for later use in patients.
How is this device regulated, and what committee oversees its submissions?
This device is regulated under 21 CFR 870.3680 as a Class III medical device, with submissions reviewed by the Cardiovascular (CV) Advisory Committee. It holds an FDA 510(k) clearance (K914489) and was determined substantially equivalent through a traditional review process.
Are there any specific storage or handling requirements mentioned for this tubing?
The provided data does not specify storage or handling instructions for the tubing itself. However, as a reusable manufacturing component for pacemaker electrodes, it should be stored and handled in accordance with Telectronics Pacing Systems’ internal quality control protocols to maintain compliance and integrity.