# Nmct 850

> Active: European Union and United States. Medical device record on deviCERTS, compiled from public registries.

- Canonical page: <https://devicerts.com/devices/nmct-850>
- Manufacturer: [GE Medical Systems Israel, Functional Imaging](https://devicerts.com/manufacturers/ge-medical-systems-israel-functional-imaging) (Israel)
- Name in the registry: NMCT 850
- Device class: Class IIb (EU MDD); Class II (US FDA)
- FDA product code: JAK, KPS
- EMDN: Z11020201 CT/GAMMA CAMERA SYSTEMS
- GMDN: Full-body CT system (37618)

## Registrations and authorizations

- **EUDAMED** · CE/MDD · European Union · Basic UDI-DI B-00840682140775 · UDI-DI 00840682140775 · registered 2026-10-15 · status: Active
- **GUDID** · GUDID listing · United States · UDI-DI 00840682140775 · listed 2018-04-23 · status: Listed (GUDID: in commercial distribution)
- **GUDID** · FDA 510(k) · United States · K173816 · decision 2018-04-17 · decision SESE · status: Active · from GUDID

## Recalls

- Z-1058-2023 · Class I · ongoing · initiated 2022-12-19: A mitigation may not be correctly implemented. If this is the case, the detector can fall, leading to life-threatening bodily injury.
- Z-1545-2021 · Class II · ongoing · initiated 2021-02-07: GE Healthcare has become aware of a potential issue on 800 family NM/CT Scanners that could cause a shift in CT radiation exposure range of up to 5cm compared to the intended radiation exposure range of the planned scan under specific workflows. The issue occurs only on a hybrid whole-body continuous F3 protocol with Zoom \< 1 where the scan range is set on the Smart Console. In some cases, this may also necessitate a re-scan of the patient, which would expose the patient to additional X-ray radiation.
- Z-1546-2021 · Class II · ongoing · initiated 2021-02-07: GE Healthcare has become aware of a potential issue on 800 family NM/CT Scanners that could cause a shift in CT radiation exposure range of up to 5cm compared to the intended radiation exposure range of the planned scan under specific workflows. The issue occurs only on a hybrid whole-body continuous F3 protocol with Zoom \< 1 where the scan range is set on the Smart Console. In some cases, this may also necessitate a re-scan of the patient, which would expose the patient to additional X-ray radiation.
- Z-0853-2021 · Class II · terminated · initiated 2020-12-10: GE Healthcare has become aware that rotor bearing screws were found loose on one detector in the field, leading to the release of one of the four rotor bearings in the detector.
- Z-0854-2021 · Class II · terminated · initiated 2020-12-10: GE Healthcare has become aware that rotor bearing screws were found loose on one detector in the field, leading to the release of one of the four rotor bearings in the detector.
- Z-2992-2020 · Class II · terminated · initiated 2020-08-14: Rotor bearing screws were found loose on detector.
- Z-2991-2020 · Class II · terminated · initiated 2020-08-14: Rotor bearing screws were found loose on detector.
- Z-1261-2019 · Class II · terminated · initiated 2019-03-20: During installation of certain Nuclear Medicine systems delivered with dismounted detectors, some detector screws may not have been secured correctly, leading to the possible loss of one detector mounting design redundancy.
- Z-1262-2019 · Class II · terminated · initiated 2019-03-20: During installation of certain Nuclear Medicine systems delivered with dismounted detectors, some detector screws may not have been secured correctly, leading to the possible loss of one detector mounting design redundancy.
- Z-1263-2019 · Class II · terminated · initiated 2019-03-20: During installation of certain Nuclear Medicine systems delivered with dismounted detectors, some detector screws may not have been secured correctly, leading to the possible loss of one detector mounting design redundancy.

## Identity

- Trade name: NM/CT 850 [EUDAMED]; NMCT [FDA GUDID (AccessGUDID)]
- Generic name: Full-body CT system [FDA GUDID (AccessGUDID)]
- Model / reference: NM/CT 850 [EUDAMED]; H3907AF [EUDAMED]; H3907AG [EUDAMED]; H3907AH [EUDAMED]; H3907AL [EUDAMED]; H3907AA [EUDAMED]; H3907AB [EUDAMED]; 850 [FDA GUDID (AccessGUDID)]

## Identifiers

- Primary DI / UDI-DI: 00840682140775 [EUDAMED, FDA GUDID (AccessGUDID)]
- Basic UDI-DI: B-00840682140775 [EUDAMED]
- 510(k) Number: K173816 [FDA GUDID (AccessGUDID)]
- FDA product code: JAK [FDA GUDID (AccessGUDID)]; KPS [FDA GUDID (AccessGUDID)]
- EMDN code: Z11020201 [EUDAMED]
- GMDN term: Full-body CT system (37618) [FDA GUDID (AccessGUDID)]

## Classification

- Device class: Class IIb [EUDAMED]; Class II [FDA GUDID (AccessGUDID)]
- Regulation number: 892.1750 [FDA GUDID (AccessGUDID)]; 892.1200 [FDA GUDID (AccessGUDID)]
- System or procedure pack: System which is a device in itself [EUDAMED]
- EU registration type: Legacy device (under a directive) [EUDAMED]
- EU market of registration: France [EUDAMED]
- GUDID distribution status: In Commercial Distribution [FDA GUDID (AccessGUDID)]

## Properties

- Measuring function: Yes [EUDAMED]
- Prescription use: Yes [FDA GUDID (AccessGUDID)]
- Serial number: Yes [FDA GUDID (AccessGUDID)]
- Manufacturing date: Yes [FDA GUDID (AccessGUDID)]
- Supplied sterile: No [EUDAMED, FDA GUDID (AccessGUDID)]
- Sterilise before use: No [EUDAMED, FDA GUDID (AccessGUDID)]
- Single use: No [FDA GUDID (AccessGUDID)]
- Implantable: No [EUDAMED, FDA GUDID (AccessGUDID)]
- Reusable: No [EUDAMED]
- Contains latex: No [EUDAMED, FDA GUDID (AccessGUDID)]
- Reprocessed single-use device: No [EUDAMED]
- Incorporates a substance derived from human blood or plasma: No [EUDAMED]
- Contains human tissues or cells: No [EUDAMED]
- Contains animal tissues or cells: No [EUDAMED]
- Administering medicine: No [EUDAMED]
- Incorporates a medicinal substance: No [EUDAMED]
- Over-the-counter: No [FDA GUDID (AccessGUDID)]
- Convenience kit: No [FDA GUDID (AccessGUDID)]
- Combination product: No [FDA GUDID (AccessGUDID)]
- HCT/P: No [FDA GUDID (AccessGUDID)]
- Premarket exempt: No [FDA GUDID (AccessGUDID)]
- Lot / batch number: No [FDA GUDID (AccessGUDID)]
- Expiration date: No [FDA GUDID (AccessGUDID)]

## Source and citation

- Cite as: Nmct 850, GE Medical Systems Israel, Functional Imaging. deviCERTS medical device catalogue. https://devicerts.com/devices/nmct-850 (data as of 2026-11-20).
- Data sources: [FDA GUDID (AccessGUDID)](https://accessgudid.nlm.nih.gov/), [EUDAMED](https://ec.europa.eu/tools/eudamed), [FDA recalls](https://open.fda.gov/apis/device/recall/)
- Registry records last synced: 2026-10-24
- Statuses computed as of: 2026-11-20
- JSON: <https://devicerts.com/devices/nmct-850.json>
- Licence: [CC BY 4.0](https://creativecommons.org/licenses/by/4.0/). The deviCERTS layout and text are licensed under CC BY 4.0. Registry data remain under their source terms: U.S. FDA data (openFDA, AccessGUDID) are U.S. public domain; EUDAMED data are subject to the European Commission reuse terms.
- Attribution: DevicErts, https://devicerts.com/devices/nmct-850
- Compiled by deviCERTS (devicerts.com) from public medical device registries (EUDAMED, European Commission; U.S. FDA via openFDA; AccessGUDID, U.S. National Library of Medicine). deviCERTS is not an official register and gives no regulatory advice: the record in the registry itself prevails.