Nobelactive Internal Connection Implant

by Nobel Biocare AB

510(k) K071370

Nobelactive Internal Connection Implant is a medical device (FDA Class II; FDA product code DZE, Implant, Endosseous, Root-Form) made by Nobel Biocare AB, cleared under FDA 510(k) K071370 on 3 Aug 2007, active as of 22 Oct 2026. One FDA recall is linked to it.

Active United States

510(k)

Valid until

No expiry

510(k) clearance is not time-limited

FDA recalls

None ongoing

4 closed

Documents

Trust

Unverified

Source FDA 510(k), synced 22 Oct 2026.

Regulatory status

as of registry sync 22 Oct 2026

RegionAuthorizationNumberDateStatus
United StatesFDA 510(k)SESE Substantially Equivalent · Traditional NumberK071370 Date3 Aug 2007ClearedStatusActive

Official records

From the FDA record

Received by the FDA
16 May 2007
FDA decision
3 Aug 2007 (Substantially Equivalent)
FDA review time
79 days from receipt to decision
Public document
510(k) summary on file with the FDA

From the FDA 510(k) record K071370 (openFDA), as read on 22 Oct 2026. Quoted as published, gaps included; nothing on this list is generated.

Recalls

4 recalls · FDA

  • 2 recalls, same reason

    • Terminated Z-1854-2020 FDA Class II initiated 9 Aug 2019 on shared 510(k) K071370
    • Terminated Z-1855-2020 FDA Class II initiated 9 Aug 2019 on shared 510(k) K071370

    Packages of abutments may contain an incorrect screw. While the screw will tighten, it cannot be guaranteed that the screw will not loosen. In case the screw loosens the abutment should be retightened with the correct screw.

    • Terminated Z-2207-2020 FDA Class II initiated 19 Jul 2019 on shared 510(k) K071370

    The top label for dental implant may incorrectly indicate the implant length. Specifically, the label may contain 11.5mm for the length, which is shorter than the actual length of the implant (15mm). An incorrect sized implant may cause patient discomfort, permanent nerve damage and may require an additional surgery.

    • Terminated Z-2250-2020 FDA Class II initiated 28 May 2019

    Packaged dental implant healing abutments were found to contain the wrong size device.

Recalls on a shared submission name another device cleared under the same FDA submission as this one.

Timeline

5 dated events

  1. Cleared FDA 510(k) K071370
  2. Recall initiated FDA recalls Z-2250-2020
  3. Recall initiated FDA recalls Z-2207-2020
  4. Recall initiated FDA recalls Z-1854-2020
  5. Recall initiated FDA recalls Z-1855-2020

Coverage

1 jurisdiction

United States of America
  • Active
  • Expiring
  • Withdrawn
  • Listed
  • Not covered

United States — FDA 510(k) Active

Specification

510(k)

510(k) Number
FDA product code
DZE
Device class
Class II
Regulation
21 CFR Part 872.3640
Advisory committee
Dental
FDA decision
SESE Substantially Equivalent

Similar devices

Other devices filed under FDA product code DZE (Implant, Endosseous, Root-Form).

Other devices from Nobel Biocare AB

See all devices from Nobel Biocare AB →