# Nova Stat Profile Prime CCS Analyzer System

> Active: United States. Medical device record on deviCERTS, compiled from public registries.

- Canonical page: <https://devicerts.com/devices/nova-stat-profile-prime-ccs-analyzer-system-chl>
- Manufacturer: [Nova Biomedical Corporation](https://devicerts.com/manufacturers/nova-biomedical-corporation) (United States, FDA 510(k) applicant)
- Name in the registry: NOVA STAT PROFILE PRIME CCS ANALYZER SYSTEM
- Device class: Class II (US FDA)
- FDA product code: CHL

## Overview

*AI-generated summary, 2026-10-01. Written by a language model from registry data. Not verified by deviCERTS or the manufacturer. The registry data is the record.*

The Nova Stat Profile Prime CCS Analyzer System is an electrode measurement device for blood gases (PCO₂, PO₂), blood pH, and related clinical chemistry parameters. It performs automated electrochemical and photometric assays on whole blood to measure critical analytes, including electrolytes and key metabolites, enabling rapid diagnostic evaluation in acute care settings. Designed for clinical chemistry applications, it provides real-time monitoring of arterial blood gases, acid-base balance, and metabolic status to support patient management in critical care environments.

This system is intended for use in clinical laboratories and point-of-care settings, where it is operated by trained personnel. Supplied as a reusable, non-sterile instrument, it requires calibration and maintenance according to manufacturer guidelines. The device is FDA-cleared under 510(k) K131703 and classified as a Class II medical device under regulation 21 CFR 862.1120. It operates in non-MRI environments and includes disposable MicroSensor Cards for sample analysis. Storage and handling follow standard laboratory protocols to ensure accuracy and reliability.

## Registrations and authorizations

- **510(k)** · FDA 510(k) · United States · K131703 · decision 2014-03-25 · decision SESE · status: Active

## Recalls

- Z-2732-2017 · Class II · terminated · initiated 2017-06-19: Software- scheduled A-QC analysis could initiate prior to a patient result being released by the operator and result in the pending patient result being overwritten with the A-QC test results.

## Identifiers

- 510(k) Number: K131703 [FDA 510(k)]
- FDA product code: CHL [FDA 510(k)]

## Classification

- Device class: Class II [FDA 510(k)]
- Regulation: 21 CFR Part 862.1120 [FDA 510(k)]
- Advisory committee: Clinical Chemistry [FDA 510(k)]
- FDA decision: SESE [FDA 510(k)]

## Source and citation

- Cite as: Nova Stat Profile Prime CCS Analyzer System, Nova Biomedical Corporation. deviCERTS medical device catalogue. https://devicerts.com/devices/nova-stat-profile-prime-ccs-analyzer-system-chl (data as of 2026-11-29).
- Data sources: [FDA 510(k)](https://open.fda.gov/apis/device/510k/), [FDA recalls](https://open.fda.gov/apis/device/recall/)
- Registry records last synced: 2026-10-05
- Statuses computed as of: 2026-11-29
- JSON: <https://devicerts.com/devices/nova-stat-profile-prime-ccs-analyzer-system-chl.json>
- Licence: [CC BY 4.0](https://creativecommons.org/licenses/by/4.0/). The deviCERTS layout and text are licensed under CC BY 4.0. Registry data remain under their source terms: U.S. FDA data (openFDA, AccessGUDID) are U.S. public domain; EUDAMED data are subject to the European Commission reuse terms.
- Attribution: DevicErts, https://devicerts.com/devices/nova-stat-profile-prime-ccs-analyzer-system-chl
- Compiled by deviCERTS (devicerts.com) from public medical device registries (EUDAMED, European Commission; U.S. FDA via openFDA; AccessGUDID, U.S. National Library of Medicine). deviCERTS is not an official register and gives no regulatory advice: the record in the registry itself prevails.