Novii Interface Cable GE Fecg
Ref 105-PT-102
Novii Interface Cable GE Fecg (105-PT-102) is an electrical-only medical device connection cable (EU MDR Class I; FDA Class II; FDA product code OSP, Uterine Electromyographic Monitor) made by Datex-Ohmeda Inc., registered in EUDAMED on 27 May 2026 (Basic UDI-DI 8406821BUG00136H6), cleared under FDA 510(k) K140862 on 27 Aug 2014 and listed in FDA GUDID since 12 Sep 2016 (UDI-DI 05060433670091), active as of 23 Oct 2026. 2 FDA recalls are linked to it.
Active
Valid until
No date given
FDA recalls
None ongoingTrust
Regulatory status
| Region | Authorization | Number | Date | Status |
|---|---|---|---|---|
| European Union | CE/MDR EUDAMED | Number8406821BUG00136H6 05060433670091 | Date27 May 2026 | StatusActive |
| United States | GUDID listing GUDID | Number05060433670091 | Date12 Sep 2016 | StatusListed |
| United States | FDA 510(k)SESE GUDID | NumberK140862 | Date27 Aug 2014 | StatusActive |
Official records
- EUDAMED public site 8406821BUG00136H6
- AccessGUDID record 05060433670091
- FDA 510(k) database K140862
From the FDA record
- Device description
- NOVII INTERFACE CABLE - GE FECG
- MRI safety
- Labeling does not contain MRI Safety Information
- Natural rubber latex
- No latex statement on the label
- Sterility
- Supplied non-sterile
Across registries
- EUDAMED Basic UDI-DI 8406821BUG00136H6 registered 27 May 2026 Active
- FDA 510(k) K140862 decided 27 Aug 2014 Active
- FDA GUDID UDI-DI 05060433670091 listed 12 Sep 2016 Listed
Recalls
-
- Terminated Z-1292-2018
if the cables of the Monica Novii System are removed by a user, and then incorrectly re-connected the Fetal Heart Rate (FHR) and Maternal Heart Rate (MHR) signals would be displayed incorrectly (swapped).
-
- Terminated Z-2588-2017
Monica Novii Wireless Patch System-Potential battery damage and excess heat through prolonged charging.
Timeline
- Cleared FDA 510(k) K140862
- Listed FDA GUDID 05060433670091
- Recall initiated FDA recalls Z-2588-2017
- Recall initiated FDA recalls Z-1292-2018
- Registered EUDAMED 8406821BUG00136H6
Coverage
- Active
- Expiring
- Withdrawn
- Listed
- Not covered
- European Union
- United States
Specification
- Trade name
- Novii Interface Cable - GE Fecg EUDAMEDNovii Interface Cable GUDID
- Generic name
- Electrical-only medical device connection cable, reusable
- Model / Ref / Catalog
- 105-PT-102, GE FECG
- Primary DI / UDI-DI
- 05060433670091
- Basic UDI-DI
- 8406821BUG00136H6
- Direct marketing DI
- 05060433670091
- 510(k) Number
- FDA product code
- OSP
- EMDN code
- Z1208010480 Cardiotocographic telemetry instruments - hardware accessories
- GMDN term
- Electrical-only medical device connection cable, reusable
- Device class
- Class I EUDAMEDClass II GUDID
- Regulation number
- 884.2720
- EU registration type
- Standard device
- EU market of registration
- France
- GUDID distribution status
- In Commercial Distribution
Truth per registry
| Field | EUDAMED | GUDID |
|---|---|---|
| Model / reference | 105-PT-102 | GE FECG |
| Device class | Class I | Class II |
Similar devices in this category
Other devices filed under PRENATAL DIAGNOSTIC INSTRUMENTS.
- Avalon Ultrasound Transducer 867246 by Philips Medizin Systeme Böblingen GmbH
- Avalon CL Basestation 866074 by Philips Medizin Systeme Böblingen GmbH
- TOCO TRANSDUCER WATERTIGHT BUTTON by WIPRO GE HEALTHCARE PRIVATE LIMITED
- TOCO TRANSDUCER 2108347 by WIPRO GE HEALTHCARE PRIVATE LIMITED
- Fetal Monitors RD-R-QP008-002/A/0 by Shenzhen Unicare Electronic Co., Ltd.
- Fetal Doppler RD-R-QP008-002/A/0 by Shenzhen Unicare Electronic Co., Ltd.
- Ultrasonic Pocket Doppler SD1 by Edan Instruments,Inc.
- astraia – software for women's health 29.01.00 by NEXUS / ASTRAIA GmbH
- Ultrasonic Pocket Doppler SD3 PRO by Edan Instruments,Inc.
- Sonio Suspect v1 by SONIO