Skip to content

Modulus TLIF Interbody System

by Nu Vasive, Incorporated

510(k) K172341

Active United States

510(k)

Valid until

No expiry

510(k) clearance is not time-limited

FDA recalls

None found

in data synced 22 Oct 2026

Documents

Trust

Unverified

Registry data, not yet checked by deviCERTS. Source FDA 510(k), synced 22 Oct 2026. What this means

Regulatory status

as of registry sync 22 Oct 2026

RegionAuthorizationNumberDateStatus
United StatesFDA 510(k)SESE Substantially Equivalent · Traditional NumberK172341 Date26 Oct 2017ClearedStatusActive

Recalls

0 recalls · FDA

No FDA recalls found in the data synced 22 Oct 2026.

Coverage

1 jurisdiction

United States of America
  • Active
  • Expiring
  • Withdrawn
  • Listed
  • Not covered

United States — FDA 510(k) Active

Specification

510(k)

Full name
NuVasive® Modulus TLIF Interbody System
510(k) Number
FDA Product Code
MAX
Device Class
Class II
Regulation
21 CFR Part 888.3080
Advisory Committee
Orthopedic
FDA Decision
SESE Substantially Equivalent

Overview

AI-generated summary, 1 Oct 2026

Written by a language model from registry data. Not verified by deviCERTS or the manufacturer. The registry data above is the record.

The Modulus TLIF Interbody System is a spinal interbody fusion device classified as an interbody spinal fusion device (FDA Product Code: MAX). It is designed for use in transforaminal lumbar interbody fusion (TLIF) procedures, providing structural support and promoting bony fusion between vertebrae in the lumbar spine. Constructed from titanium alloy, the system offers mechanical stability and corrosion resistance, with a porous design to enhance osseointegration. Its radiolucent properties facilitate intraoperative imaging and postoperative assessment.

The system is supplied as a sterile, single-use device intended for surgical use in spinal fusion procedures. It is regulated under the FDA’s 510(k) pathway, with clearance granted as substantially equivalent to a predicate device. Implants are available in various sizes to accommodate different anatomical requirements, and the porous titanium structure is optimized for strength while maintaining radiolucency. Storage and handling follow standard sterile surgical instrument protocols, ensuring compatibility with MRI environments where applicable. No additional regulatory approvals beyond the FDA 510(k) clearance (K172341) are stated in the specifications.

Other devices from Nu Vasive, Incorporated

See all devices from Nu Vasive, Incorporated →

Questions

AI-generated answers, 1 Oct 2026

Written by a language model from registry data. Not verified by deviCERTS or the manufacturer. The registry data above is the record.

  • What is the NuVasive Modulus TLIF Interbody System used for?

    The NuVasive Modulus TLIF Interbody System is designed specifically for transforaminal lumbar interbody fusion (TLIF) procedures. It is used to provide structural support between vertebrae in the lumbar spine, promoting bony fusion while maintaining stability. The system’s porous titanium alloy construction encourages osseointegration, ensuring long-term integration with the surrounding bone.

  • How is the Modulus TLIF Interbody System supplied and prepared for use?

    The system is supplied as a sterile, single-use device, meaning each implant is intended for one surgical procedure only. This ensures patient safety by preventing cross-contamination. Before use, follow standard sterile surgical instrument protocols to maintain sterility and compatibility with intraoperative imaging.

  • What materials are used in the Modulus TLIF Interbody System, and why?

    The system is constructed from titanium alloy, chosen for its mechanical stability and corrosion resistance. The porous design of the titanium enhances osseointegration, allowing the implant to bond effectively with the patient’s bone. Additionally, its radiolucent properties enable clear intraoperative imaging and postoperative assessment.

  • Are there different sizes available for the Modulus TLIF Interbody System?

    Yes, the Modulus TLIF Interbody System is available in various sizes to accommodate different anatomical requirements. This modularity ensures that surgeons can select the appropriate implant dimensions for optimal fit and fusion outcomes in each patient’s specific lumbar spine anatomy.

  • Can the Modulus TLIF Interbody System be used in MRI environments?

    The system is designed with radiolucent properties, which means it is compatible with MRI environments where applicable. However, always verify compatibility with your specific MRI machine settings and follow manufacturer guidelines to ensure safe imaging without interference or artifacts.