NX 4.0

by Agfa NV

Ref XCU8O

NX 4.0 (XCU8O) is a medical device (EU MDR Class IIb; FDA Class II; FDA product code JAA, System, x-ray, fluoroscopic, image-intensified; EMDN category remote control tables - software accessories) made by Agfa NV, registered in EUDAMED on 24 Feb 2025 (Basic UDI-DI 5414904272909YU) with CE/MDR certificate 28620125060 valid until 31 May 2027, cleared under FDA 510(k) K212145 on 31 Aug 2021 (2 earlier submissions) and listed in FDA GUDID since 18 Jul 2023 (UDI-DI 05414904233320), active as of 22 Oct 2026. 3 FDA recalls are linked to it.

Expiring Expiring in European Union. Active in United States. Also listed in GUDID (US).

CE MDR 510(k)

Valid until

31 May 2027

CE MDR certificate

FDA recalls

2 ongoing

This device is named in the recall

Documents

1 certificate

Certifier Intertek Medical Notified Body AB

Trust

Unverified

Source EUDAMED, GUDID, synced 22 Oct 2026.

Regulatory status

as of registry sync 22 Oct 2026

RegionAuthorizationNumberDateStatus
European UnionCE/MDR EUDAMED Number5414904272909YU Basic UDI-DI 05414904233320UDI-DIDate24 Feb 2025RegisteredStatusActive
United StatesGUDID listing GUDID Number05414904233320 UDI-DI Date18 Jul 2023ListedStatusListed GUDID: in commercial distribution
United StatesFDA 510(k)SESE GUDID from GUDID Substantially Equivalent · Traditional NumberK212145 Date31 Aug 2021DecidedStatusActive

Official records

From the FDA record

MRI safety
Labeling does not contain MRI Safety Information
Natural rubber latex
No latex statement on the label
Sterility
Supplied non-sterile

From the GUDID record (AccessGUDID), as read on 30 May 2026, as the labeller entered it.

Across registries

3 registries list this device

  • EUDAMED Basic UDI-DI 5414904272909YU registered 24 Feb 2025 Active· +1 more in the status table
  • FDA 510(k) K212145 decided 31 Aug 2021 Active· +2 more in the status table
  • FDA GUDID UDI-DI 05414904233320 listed 18 Jul 2023 Listed

Certificates

1 certificate · EUDAMED

EUDAMED certificates (1)
  • 28620125060 Expiring Supplemented Expires in 192 days

    Quality management system EU MDR

    Issued
    14 Sep 2023
    Expires
    31 May 2027
    Reason
    Add device or group

Recalls

5 recalls · 2 ongoing · FDA

    • Ongoing Z-0923-2026 FDA Class II initiated 18 Nov 2025 on shared 510(k) K183275

    It is possible to exceed the maximum allowed Air Kerma rate (AKR) of 88mGy/min for pulsed fluoro exams. This can happen in case the framerate is increased on the NX workstation when ABS is not enabled.

    • Ongoing Z-2738-2024 FDA Class II initiated 29 Jul 2024

    Potential for the front lever chain of the DR 800 table to fail.

    • Terminated Z-2202-2020 FDA Class II initiated 6 Apr 2020

    Under specific conditions (Fluoroscopic exam, ABS=OFF, manual change of parameters) wrong calculation of the dose/minute for fluoroscopy exams can be possible

    • Terminated Z-1502-2020 FDA Class II initiated 10 Feb 2020 on shared 510(k) K183275

    Tomosynthesis image acquisition sequence did not stop automatically after expected number of exposures.

    • Terminated Z-2056-2019 FDA Class II initiated 27 Jun 2019

    The exposed area of fluo exams possibly does not match the active area of the detector within specified limits.

Recalls on a shared submission name another device cleared under the same FDA submission as this one.

Timeline

12 dated events

  1. Recall initiated FDA recalls Z-2056-2019
  2. Recall initiated FDA recalls Z-1502-2020
  3. Recall initiated FDA recalls Z-2202-2020
  4. Cleared FDA 510(k) K212145
  5. Listed FDA GUDID 05414904233320
  6. Certificate issued EUDAMED 28620125060
  7. Recall initiated FDA recalls Z-2738-2024
  8. Registered EUDAMED 5414904272909YU
  9. Recall initiated FDA recalls Z-0923-2026
  10. Certificate expires EUDAMED 28620125060

2 earlier events are in the sections above.

Coverage

2 jurisdictions

United States of AmericaSwedenFinlandLatviaEstoniaDenmarkLithuaniaIrelandNetherlandsGermanyPolandFranceBelgiumLuxembourgCzech RepublicSlovakiaAustriaHungaryRomaniaSloveniaBulgariaPortugalSpainItalyCroatiaGreeceMaltaCyprus
  • Active
  • Expiring
  • Withdrawn
  • Listed
  • Not covered
  • European Union CE/MDR Expiring
  • United States FDA 510(k) Active

Specification

EUDAMED · GUDID

Generic name
Radiology DICOM image processing application software
Device name
NX Software
Model / Ref / Catalog
XCU8O, V4.0
Primary DI / UDI-DI
05414904233320
Basic UDI-DI
5414904272909YU
FDA product code
JAA
EMDN code
Z11030782 Remote control tables - software accessories
GMDN term
Radiology DICOM image processing application software
Device class
Class IIb EUDAMED
Class II GUDID
Regulation number
892.1650
Special device type
Software
EU registration type
Standard device
EU market of registration
Belgium
GUDID distribution status
In Commercial Distribution

Truth per registry

2 sources · 2 fields differ

FieldEUDAMEDGUDID
Model / referenceEUDAMED
XCU8O
GUDID
V4.0
Device classEUDAMED
Class IIb
GUDID
Class II

Device class is stated on each registry's own scale: Class IIb in the EU (EUDAMED), Class II in the US (FDA GUDID). EU and US classes are different schemes, so this is not a disagreement.

Manufacturer details

EUDAMED SRN
BE-MF-000000571

Similar devices in this category

Other devices filed under DIAGNOSTIC AND INTERVENTIONAL RADIOLOGY INSTRUMENTS.

Other devices from Agfa NV

See all devices from Agfa NV →

Properties

  • Measuring function
  • Prescription use
Other properties (23, all answered No)