Skip to content

O-Two E700, O-Two E600, O-Two E500

by O-Two Medical Technologies Inc

510(k) K141595

O-Two E700, O-Two E600, O-Two E500 is a medical device (FDA Class II; FDA product code BTL, Ventilator, Emergency, Powered (Resuscitator)) made by O-Two Medical Technologies Inc, cleared under FDA 510(k) K141595 on 16 Mar 2015, active as of 22 Oct 2026. 3 FDA recalls are linked to it.

Active United States

510(k)

Valid until

No expiry

510(k) clearance is not time-limited

FDA recalls

None ongoing

3 closed

Documents

Trust

Unverified

Source FDA 510(k), synced 22 Oct 2026.

Regulatory status

as of registry sync 22 Oct 2026

RegionAuthorizationNumberDateStatus
United StatesFDA 510(k)SESE Substantially Equivalent · Traditional NumberK141595 Date16 Mar 2015ClearedStatusActive

Official records

From the FDA record

Received by the FDA
13 Jun 2014
FDA decision
16 Mar 2015 (Substantially Equivalent)
FDA review time
276 days from receipt to decision
Public document
510(k) summary on file with the FDA

From the FDA 510(k) record K141595 (openFDA), as read on 22 Oct 2026. Quoted as published, gaps included; nothing on this list is generated.

Recalls

3 recalls · FDA

  • 3 recalls, same reason

    • Terminated Z-0976-2019 FDA Class I initiated 12 Feb 2019
    • Terminated Z-0977-2019 FDA Class I initiated 12 Feb 2019
    • Terminated Z-0978-2019 FDA Class I initiated 12 Feb 2019

    There is a potential for the unit to catch fire due to one of the screen retaining screws being incorrectly inserted. Due to this improper screw insertion the screw sat higher than normal allowing it to contact the underside of the main board causing the screw to rub against the bottom side of the board, wearing away the insulation layer and creating a short circuit.

Timeline

4 dated events

  1. Cleared FDA 510(k) K141595
  2. Recall initiated FDA recalls Z-0976-2019
  3. Recall initiated FDA recalls Z-0977-2019
  4. Recall initiated FDA recalls Z-0978-2019

Coverage

1 jurisdiction

United States of America
  • Active
  • Expiring
  • Withdrawn
  • Listed
  • Not covered

United States — FDA 510(k) Active

Specification

510(k)

510(k) Number
FDA product code
BTL
FDA applicant
O-Two Medical Technologies, Inc.
Device class
Class II
Regulation
21 CFR Part 868.5925
Advisory committee
Anesthesiology
FDA decision
SESE Substantially Equivalent

Devices cleared under K141595

3 devices · FDA GUDID

Devices that FDA's GUDID lists as cleared or approved under this submission number. One submission usually covers a whole product family, so the sizes and models are listed here once.

Devices cleared under K141595
UDI-DISize and differences
o_two e500 01EVE500
O-Two Medical Technologies Inc
01EVE500 / 01EVE50007540195033054
Weight 2.4 kg; Height 155 mm; Length 200 mm; Length 250 mm
On the market
o_two e600 01EVE600
O-Two Medical Technologies Inc
01EVE600 / 01EVE60007540195033030
Weight 2.4 kg; Height 155 mm; Width 200 mm; Length 250 mm
On the market
o_two e700 01EVE700
O-Two Medical Technologies Inc
01EVE700 / 01EVE70007540195033016
Weight 2.4 kg; Height 155 mm; Width 200 mm; Length 250 mm
On the market

Similar devices

Other devices filed under FDA product code BTL (Ventilator, Emergency, Powered (Resuscitator)).

Other devices from O-Two Medical Technologies Inc

See all devices from O-Two Medical Technologies Inc →