O640 Upgrade H3100ZC

by GE Medical Systems Israel, Functional Imaging

O640 Upgrade H3100ZC is a full-body CT system (FDA Class II) made by GE Medical Systems Israel, Functional Imaging, cleared under FDA 510(k) K121019 on 19 Apr 2012 and listed in FDA GUDID since 28 Jun 2017 (UDI-DI 00840682123730), active as of 23 Oct 2026. 6 FDA recalls are linked to it.

Active United States. Also listed in GUDID (US).

510(k)

Valid until

No expiry

510(k) clearance is not time-limited

FDA recalls

2 ongoing

This device is named in the recall

Documents

510(k) K121019

FDA submission, from GUDID

Trust

Unverified

Source GUDID, synced 23 Oct 2026.

Regulatory status

as of registry sync 23 Oct 2026

RegionAuthorizationNumberDateStatus
United StatesGUDID listing Number00840682123730 UDI-DI Date28 Jun 2017ListedStatusListed GUDID: in commercial distribution
United StatesFDA 510(k)SESE from GUDID Substantially Equivalent · Traditional NumberK121019 Date19 Apr 2012DecidedStatusActive

Official records

From the FDA record

Device description
D630 TO O640 UPGRDAE COLLECTOR
MRI safety
Labeling does not contain MRI Safety Information
Natural rubber latex
No latex statement on the label
Sterility
Supplied non-sterile

From the GUDID record (AccessGUDID), as read on 23 Oct 2026, as the labeller entered it.

Across registries

2 registries list this device

  • FDA 510(k) K121019 decided 19 Apr 2012 Active
  • FDA GUDID UDI-DI 00840682123730 listed 28 Jun 2017 Listed

Recalls

6 recalls · 2 ongoing · FDA

    • Ongoing Z-0896-2025 FDA Class II initiated 18 Dec 2024

    GE HealthCare has become aware that certain Infinia, VariCam/VG/VH, Brivo NM 615, Discovery NM 630, Discovery NM/CT 670, and Optima NM/CT 640 Nuclear Medicine systems (see Affected Products Details and Appendices) could have been transported or relocated without proper detector support, which can result in excessive load being applied to the detector mounting mechanisms. If this occurs, it can potentially result in a detector fall and lead to life-threatening bodily injury.

    • Ongoing Z-1056-2023 FDA Class I initiated 19 Dec 2022

    A mitigation may not be correctly implemented. If this is the case, the detector can fall, leading to life-threatening bodily injury.

    • Terminated Z-0858-2021 FDA Class II initiated 10 Dec 2020

    GE Healthcare has become aware that rotor bearing screws were found loose on one detector in the field, leading to the release of one of the four rotor bearings in the detector.

    • Terminated Z-1266-2019 FDA Class II initiated 20 Mar 2019

    During installation of certain Nuclear Medicine systems delivered with dismounted detectors, some detector screws may not have been secured correctly, leading to the possible loss of one detector mounting design redundancy.

    • Terminated Z-0367-2014 FDA Class II initiated 25 Oct 2013

    GE Healthcare has recently become aware of a potential safety issue related to a SPECT scan procedure used for pulmonary imaging. Contact between the Detector (GE Healthcare Discovery NM/CT 670, and/or Optima NM/CT 640, and/or Discovery NM630, and/or Brivo NM 615 all configurations) and the Patient's elbow may occur during SPECT protocols using 450 angular steps in scenarios when a Patients a

    • Terminated Z-1793-2013 FDA Class I initiated 13 Jun 2013

    GE became aware of an incident at a VA Medical Center facility in the US in which a patient died due to injuries sustained while being scanned on an Infinia Hawkeye 4 Nuclear Medicine System. UPDATE: On July 03, 2013 GE notified hospitals that they are recalling several Nuclear Medicine Imaging Systems because serious injuries or deaths could occur due to the failure mode associated with this re

Timeline

8 dated events

  1. Cleared FDA 510(k) K121019
  2. Recall initiated FDA recalls Z-1793-2013
  3. Recall initiated FDA recalls Z-0367-2014
  4. Listed FDA GUDID 00840682123730
  5. Recall initiated FDA recalls Z-1266-2019
  6. Recall initiated FDA recalls Z-0858-2021
  7. Recall initiated FDA recalls Z-1056-2023
  8. Recall initiated FDA recalls Z-0896-2025

Coverage

1 jurisdiction

United States of America
  • Active
  • Expiring
  • Withdrawn
  • Listed
  • Not covered

United States — FDA 510(k) Active

Specification

GUDID

Trade name
O640 Upgrade
Generic name
Full-body CT system
Model / reference
H3100ZC
Primary DI / UDI-DI
00840682123730
510(k) Number
FDA product code
JAK, KPS
GMDN term
Full-body CT system
Device class
Class II
Regulation number
892.1750, 892.1200
GUDID distribution status
In Commercial Distribution

Other devices from GE Medical Systems Israel, Functional Imaging

See all devices from GE Medical Systems Israel, Functional Imaging →

Properties

  • Prescription use
  • Lot / batch number
  • Serial number
  • Manufacturing date
Other properties (11, all answered No)