Ocean 2012-320
Ocean 2012-320, a thoracic suction collection container (FDA Class II; FDA product code KDQ, Bottle, Collection, Vacuum) made by Atrium Medical Corporation, was cleared under FDA 510(k) K043582 on 21 Jan 2005 and listed in FDA GUDID on 24 Sep 2015 (UDI-DI 00650862101027); the registry lists it as not in commercial distribution (GUDID) as of 22 Oct 2026. FDA recalls on record: 7.
Active
Valid until
No expiry
FDA recalls
4 ongoingDocuments
Trust
Regulatory status
| Region | Authorization | Number | Date | Status |
|---|---|---|---|---|
| United States | GUDID listing | Number00650862101027 | Date24 Sep 2015 | StatusListed |
| United States | FDA 510(k)SESE | NumberK043582 | Date21 Jan 2005 | StatusActive |
Official records
- AccessGUDID record 00650862101027
- FDA 510(k) database K043582
From the FDA record
- Device description
- OCEAN DRAIN, PEDIATRIC, IN-LINE, STOP
- MRI safety
- Labeling does not contain MRI Safety Information
- Natural rubber latex
- No latex statement on the label
- Sterility
- Supplied sterile
Across registries
- FDA 510(k) K043582 decided 21 Jan 2005 Active
- FDA GUDID UDI-DI 00650862101027 listed 24 Sep 2015 Listed
Recalls
-
- Ongoing Z-0486-2024
Product was re-processed and re-sterilized by a third party using packaging configurations and a sterilization process which are not approved by the manufacture and lack validation.
-
- Ongoing Z-0235-2023
Warehouse experienced temperature excursions in July and August 2021. It was determined that there were no associated harms to patients.
-
- Ongoing Z-1607-2022
Facility Temperature excursions (from June 2021-August 2021) prior to delivery; exposure to higher temperatures may have impacted product effectiveness. All lots received between 06/01/21-9/30/21.
-
- Ongoing Z-0307-2022
Inadequate/inappropriate Set-Up Instructions, which may result in delay in treatment and an unreasonable risk of harm to the patient
-
- Terminated Z-1210-2017
- Terminated Z-1209-2017
- Terminated Z-1206-2017
- Terminated Z-1205-2017
Chest drains manual vent valve located at the top of affected chest drains could potentially not re-seal after being depressed.
-
- Terminated Z-1938-2015
- Terminated Z-1935-2015
- Terminated Z-1937-2015
- Terminated Z-1936-2015
Chest drains have a missing o-ring
-
- Terminated Z-1959-2014
Product that was previously recalled because the Chest Drain tubing of the ATS Blood recovery may leak or disconnect, was released for distribution in error.
-
- Terminated Z-0743-2014
- Terminated Z-0740-2014
- Terminated Z-0738-2014
- Terminated Z-0736-2014
- Terminated Z-0739-2014
- Terminated Z-0735-2014
- Terminated Z-0742-2014
- Terminated Z-0741-2014
- Terminated Z-0737-2014
Chest Drain tubing of of the ATS Blood recovery may leak or disconnect
Timeline
- Recall initiated FDA recalls Z-1936-2015
- Listed FDA GUDID 00650862101027
- Recall initiated FDA recalls Z-1210-2017
- Recall initiated FDA recalls Z-1209-2017
- Recall initiated FDA recalls Z-1206-2017
- Recall initiated FDA recalls Z-1205-2017
- Recall initiated FDA recalls Z-0307-2022
- Recall initiated FDA recalls Z-1607-2022
- Recall initiated FDA recalls Z-0235-2023
- Recall initiated FDA recalls Z-0486-2024
Coverage
- Active
- Expiring
- Withdrawn
- Listed
- Not covered
United States — FDA 510(k) Active
Specification
- Trade name
- Ocean
- Generic name
- Thoracic suction collection container
- Model / reference
- 2012-320
- Primary DI / UDI-DI
- 00650862101027
- 510(k) Number
- FDA product code
- KDQ
- GMDN term
- Thoracic suction collection container
- Device class
- Class II
- Regulation number
- 880.6740
- GUDID distribution status
- Not in Commercial Distribution
Similar devices
Other devices filed under FDA product code KDQ (BOTTLE, COLLECTION, VACUUM).
- Vide ST380-0006 by Alleva Medical Limited
- ELECTRO-SUCTION UNIT by JEDMED Instrument Company
- Heimlich valve 10530 by REDAX SPA
- THORA-KLEX CHEST DRAINAGE UNIT by Davol Inc.
- One-Vac™ 00884450749609 EVAC1000/A by Merit Medical Systems, Inc.
- MUCUS SPECIMEN TRAP by SAGE PRODUCTS LLC
- PLEURAL DRAINAGE SYSTEM #PDS-4300 by Bentley Laboratories, Inc.
- NIFA NON INVASIVE FLUTTER ASSEMBLY by Emergency Management Products, Inc.
- VAC-RITE by Medical Development Co.
- BARD PARKER THORACIC VENT by Bd Becton Dickinson Vacutainer Systems Preanalytic