Skip to content

OFA

by Konan Medical USA, Inc.

Ref PR-OFA-AModel OFA-001

PR-OFA-A is a perimeter (EU MDR Class IIa; FDA Class I; FDA product code HPT, Perimeter, Automatic, Ac-Powered) made by Konan Medical USA, Inc., registered in EUDAMED on 10 Nov 2025 (Basic UDI-DI 458227526KONAN-OPELW) and listed in FDA GUDID since 2 Aug 2024 (UDI-DI 04582275270075), active as of 22 Oct 2026.

Active European Union. Also listed in GUDID (US).

CE MDR

Valid until

No date given

EUDAMED holds no validity date

FDA recalls

Not checked

No FDA submission to match recalls against

Documents

None linked in EUDAMED

A group certificate may exist

Trust

Unverified

Source EUDAMED, GUDID, synced 22 Oct 2026.

Regulatory status

as of registry sync 22 Oct 2026

RegionAuthorizationNumberDateStatus
European UnionCE/MDR EUDAMED Number458227526KONAN-OPELW Basic UDI-DI 04582275270075UDI-DIDate10 Nov 2025RegisteredStatusActive
United StatesGUDID listing GUDID Number04582275270075 UDI-DI Date2 Aug 2024ListedStatusListed GUDID: in commercial distribution

Official records

From the FDA record

MRI safety
Labeling does not contain MRI Safety Information
Natural rubber latex
No latex statement on the label
Sterility
Supplied non-sterile

From the GUDID record (AccessGUDID), as read on 27 May 2026, as the labeller entered it.

Across registries

2 registries list this device

  • EUDAMED Basic UDI-DI 458227526KONAN-OPELW registered 10 Nov 2025 Active
  • FDA GUDID UDI-DI 04582275270075 listed 2 Aug 2024 Listed

Timeline

2 dated events

  1. Listed FDA GUDID 04582275270075
  2. Registered EUDAMED 458227526KONAN-OPELW

Coverage

2 jurisdictions

United States of AmericaSwedenFinlandLatviaEstoniaDenmarkLithuaniaIrelandNetherlandsGermanyPolandFranceBelgiumLuxembourgCzech RepublicSlovakiaAustriaHungaryRomaniaSloveniaBulgariaPortugalSpainItalyCroatiaGreeceMaltaCyprus
  • Active
  • Expiring
  • Withdrawn
  • Listed
  • Not covered
  • European Union CE/MDR Active
  • United States GUDID listing Listed

Specification

EUDAMED · GUDID

Generic name
Perimeter, automatic
Device name
ObjectiveFIELD Analyzer
Model / reference
OFA-001, PR-OFA-A
Primary DI / UDI-DI
04582275270075
Basic UDI-DI
458227526KONAN-OPELW
Direct marketing DI
04582275270075
FDA product code
HPT
EMDN code
Z1212012001 Visual functional assessment equipment
GMDN term
Perimeter, automatic
Device class
Class IIa EUDAMED
Class I GUDID
Regulation number
886.1605
EU registration type
Standard device
EU market of registration
Germany
GUDID distribution status
In Commercial Distribution

Truth per registry

2 sources · 1 field differs

FieldEUDAMEDGUDID
Device classEUDAMED
Class IIa
GUDID
Class I

Device class is stated on each registry's own scale: Class IIa in the EU (EUDAMED), Class I in the US (FDA GUDID). EU and US classes are different schemes, so this is not a disagreement.

Manufacturer details

EUDAMED SRN
US-MF-000014687
Authorised representative
Medical Technology Promedt Consulting GmbH DE-AR-000000085

Similar devices in this category

Other devices filed under VISUAL FUNCTIONAL ASSESSMENT EQUIPMENT.

Other devices from Konan Medical USA, Inc.

See all devices from Konan Medical USA, Inc. →

Properties

  • Serial number