Skip to content

Olympus A20978A

by Olympus Winter & Ibe GmbH

Ref A20978A

Olympus A20978A is an endoscope assembly adaptor (EU MDD Class I; FDA Class II; FDA product code GCP, Endoscope, Ac-Powered And Accessories) made by Olympus Winter & Ibe GmbH, registered in EUDAMED on 5 Nov 2026 (Basic UDI-DI B-04042761020411) and listed in FDA GUDID since 21 Sep 2016 (UDI-DI 04042761020411), active as of 16 Nov 2026.

Active European Union. Also listed in GUDID (US).

CE MDD

Valid until

No date given

EUDAMED holds no validity date

FDA recalls

Not checked

No FDA submission to match recalls against

Documents

None linked in EUDAMED

A group certificate may exist

Trust

Unverified

Source EUDAMED, GUDID, synced 16 Nov 2026.

Regulatory status

as of registry sync 16 Nov 2026

RegionAuthorizationNumberDateStatus
European UnionCE/MDD EUDAMED NumberB-04042761020411 Basic UDI-DI 04042761020411UDI-DIDate5 Nov 2026RegisteredStatusActive
United StatesGUDID listing GUDID Number04042761020411 UDI-DI Date21 Sep 2016ListedStatusListed GUDID: in commercial distribution

Official records

From the FDA record

Device description
Bridge, for 4 mm telescope, cystoscope
MRI safety
Labeling does not contain MRI Safety Information
Natural rubber latex
No latex statement on the label
Sterility
Supplied non-sterile; sterilise before use (Moist Heat or Steam Sterilization)

From the GUDID record (AccessGUDID), as read on 16 Nov 2026, as the labeller entered it.

Across registries

2 registries list this device

  • EUDAMED Basic UDI-DI B-04042761020411 registered 5 Nov 2026 Active
  • FDA GUDID UDI-DI 04042761020411 listed 21 Sep 2016 Listed

Timeline

2 dated events

  1. Listed FDA GUDID 04042761020411
  2. Registered EUDAMED B-04042761020411

Coverage

2 jurisdictions

United States of AmericaSwedenFinlandLatviaEstoniaDenmarkLithuaniaIrelandNetherlandsGermanyPolandFranceBelgiumLuxembourgCzech RepublicSlovakiaAustriaHungaryRomaniaSloveniaBulgariaPortugalSpainItalyCroatiaGreeceMaltaCyprus
  • Active
  • Expiring
  • Withdrawn
  • Listed
  • Not covered
  • European Union CE/MDD Active
  • United States GUDID listing Listed

Specification

EUDAMED · GUDID

Trade name
Olympus
Generic name
Endoscope assembly adaptor
Model / Ref / Catalog
A20978A
Primary DI / UDI-DI
04042761020411
Basic UDI-DI
B-04042761020411
FDA product code
GCP
EMDN code
Z12020780 Genitourinary endoscopy instruments - hardware accessories
GMDN term
Endoscope assembly adaptor
Device class
Class I EUDAMED
Class II GUDID
Regulation number
876.1500
EU registration type
Legacy device (under a directive)
EU market of registration
Germany
GUDID distribution status
In Commercial Distribution
Sterilisation method
Moist Heat or Steam Sterilization

Truth per registry

2 sources · 1 field differs

FieldEUDAMEDGUDID
Device classEUDAMED
Class I
GUDID
Class II

Device class is stated on each registry's own scale: Class I in the EU (EUDAMED), Class II in the US (FDA GUDID). EU and US classes are different schemes, so this is not a disagreement.

Similar devices in this category

Other devices filed under GENITOURINARY ENDOSCOPY INSTRUMENTS - HARDWARE ACCESSORIES.

Other devices from Olympus Winter & Ibe GmbH

See all devices from Olympus Winter & Ibe GmbH →

Properties

  • Sterilise before use
  • Prescription use
  • Lot / batch number
Other properties (22, all answered No)