Olympus A4770
Ref A4770
Olympus A4770 is an endoscope sheath (EU MDD Class IIa; FDA Class II; FDA product code HIH, Hysteroscope (And Accessories)) made by Olympus Winter & Ibe GmbH, registered in EUDAMED on 10 Sep 2026 (Basic UDI-DI B-04042761006705), cleared under FDA 510(k) K897003 on 16 Mar 1990 and listed in FDA GUDID since 21 Sep 2016 (UDI-DI 04042761006705), active as of 16 Nov 2026. One FDA recall is linked to it.
Active
CE MDD 510(k)
Valid until
No date given
FDA recalls
1 ongoingTrust
Regulatory status
| Region | Authorization | Number | Date | Status |
|---|---|---|---|---|
| European Union | CE/MDD EUDAMED | NumberB-04042761006705 04042761006705 | Date10 Sep 2026 | StatusActive |
| United States | GUDID listing GUDID | Number04042761006705 | Date21 Sep 2016 | StatusListed |
| United States | FDA 510(k)SESE GUDID | NumberK897003 | Date16 Mar 1990 | StatusActive |
Official records
- EUDAMED public site B-04042761006705
- AccessGUDID record 04042761006705
- FDA 510(k) database K897003
From the FDA record
- Device description
- Sheath, 4 mm
- MRI safety
- Labeling does not contain MRI Safety Information
- Natural rubber latex
- No latex statement on the label
- Sterility
- Supplied non-sterile; sterilise before use (Moist Heat or Steam Sterilization)
Across registries
- EUDAMED Basic UDI-DI B-04042761006705 registered 10 Sep 2026 Active
- FDA 510(k) K897003 decided 16 Mar 1990 Active
- FDA GUDID UDI-DI 04042761006705 listed 21 Sep 2016 Listed
Recalls
-
- Ongoing Z-2029-2024
The required leakage test was not performed following of a re-work for a non-conformity. This could potentially result in liquid ingress into the eyepiece and cause a foggy image.
Timeline
- Cleared FDA 510(k) K897003
- Listed FDA GUDID 04042761006705
- Recall initiated FDA recalls Z-2029-2024
- Registered EUDAMED B-04042761006705
Coverage
- Active
- Expiring
- Withdrawn
- Listed
- Not covered
- European Union
- United States
Specification
- Trade name
- Sheath, 4 mm EUDAMEDOlympus GUDID
- Generic name
- Endoscope sheath, reusable
- Model / Ref / Catalog
- A4770
- Primary DI / UDI-DI
- 04042761006705
- Basic UDI-DI
- B-04042761006705
- 510(k) Number
- FDA product code
- HIH
- EMDN code
- Z12020704 Hysteroscopes
- GMDN term
- Endoscope sheath, reusable
- Device class
- Class IIa EUDAMEDClass II GUDID
- Regulation number
- 884.1690
- EU registration type
- Legacy device (under a directive)
- EU market of registration
- Germany
- GUDID distribution status
- In Commercial Distribution
- Sterilisation method
- Moist Heat or Steam Sterilization
Truth per registry
| Field | EUDAMED | GUDID |
|---|---|---|
| Device class | Class IIa | Class II |
Similar devices in this category
Other devices filed under HYSTEROSCOPES.
- TruClear 7209808S by Covidien LP
- Omni Hysteroscope 60-200 by Hologic
- PANOVIEW PLUS 8989412 8989.412 by Richard Wolf GmbH
- 30 Degree 6mm operative sheath 60-203-30 by Hologic
- Single Use Video Hysteroscope H-20H-0-225C by Wuxi Isee Medical Technology Co., Ltd
- TruClear 72203506 by Covidien LP
- Single-Use Video Hysteroscope RP-G-C0101 by Guangzhou Red Pine Medical Instrument Co.,Ltd.
- Single-Use Video Hysteroscope RP-G-C24 by Guangzhou Red Pine Medical Instrument Co.,Ltd.
- Single-use Hystero Videoscope SHV-B2 by SCIVITA MEDICAL TECHNOLOGY CO., LTD.
- Aveta Coral Disposable Hysteroscope 214-251 by Meditrina, Inc.