Olympus AU400 Clinical Chemistry Analyzer

by Olympus America, Inc.

510(k) K981743

Active United States

510(k)

Valid until

No expiry

510(k) clearance is not time-limited

FDA recalls

1 ongoing

Recall on shared 510(k) K981743; other models may be affected

Documents

Trust

Unverified

Registry data, not yet checked by deviCERTS. Source FDA 510(k), synced 22 Oct 2026. What this means

Regulatory status

as of registry sync 22 Oct 2026

RegionAuthorizationNumberDateStatus
United StatesFDA 510(k)SESE Substantially Equivalent · Special NumberK981743 Date9 Jun 1998ClearedStatusActive

Recalls

5 recalls · 1 ongoing · FDA

    • Ongoing Z-3332-2026 FDA Class II initiated 3 Aug 2026 on shared 510(k) K981743

    Certain AU480 chemistry analyzers, with Windows 10 IoT Enterprise 2021 LTSC PCs, may output the message System Stopped By Fatal Error: DBConnectionError AlarmDB when launching the instrument software, using PC pre-installed with Microsoft SQL Server 2022 Express. When this occurs, AlarmDB becomes unreadable and the instrument software cannot be started. This causes a delay in obtaining patient results.

    • Completed Z-1907-2025 FDA Class II initiated 30 Apr 2025

    A manufacturing defect in the sample probe (S probe). The corners of the tip of the defective S probe are rounded and chamfered, which can prevent the proper formation of the "air layer" required for normal dispensing. The air layer is the air space that separates the cleaning water filled in the probe from the sample sucked into the probe. Maintaining this air space prevents the cleaning water and the sample from mixing. In the defective S probe, the "air layer" was not properly formed, causing the cleaning water and the sample to mix diluting the sample. As a result, the sample mixture dispensed into the cuvette has a lower concentration than the original sample, and the analyte concentration measured is lower than expected results.

  • 2 recalls, same reason

    • Terminated Z-0152-2014 FDA Class II initiated 9 Sep 2013 on shared 510(k) K981743
    • Terminated Z-0153-2014 FDA Class II initiated 9 Sep 2013 on shared 510(k) K981743

    The recall was initiated because Beckman Coulter has confirmed that some AU Clinical Chemistry Analyzer ISE units can experience premature ISE REF (Reference) valve failure. Premature valve failure can be detected by the presence of air bubbles in the ISE REF solution tubing on the ISE unit. If air bubbles are present, accuracy of the ISE test results may be affected.

    • Terminated Z-0974-2012 FDA Unclassified (pre-2012) initiated 12 Jul 2010 on shared 510(k) K981743

    The recall was initiated because Beckman has confirmed that the AU Clinical Chemistry Analyzers may experience cuvette overflow.

Recalls on a shared submission name another device cleared under the same FDA submission as this one.

Coverage

1 jurisdiction

United States of America
  • Active
  • Expiring
  • Withdrawn
  • Listed
  • Not covered

United States — FDA 510(k) Active

Specification

510(k)

510(k) Number
FDA Product Code
CKB
Device Class
Class II
Regulation
21 CFR Part 862.1020
Advisory Committee
Clinical Chemistry
FDA Decision
SESE Substantially Equivalent