omniTRAX Patient Tracker Starter Kit H4913AT

by Civco Medical Instruments Co., Inc.

Listed FDA GUDID listing, not in commercial distribution

Valid until

Not applicable

Database listing, no authorization

FDA recalls

8 ongoing

This device is named in the recall

Documents

None

No authorization documents

Trust

Unverified

Registry data, not yet checked by deviCERTS. Source GUDID, synced 23 Oct 2026. What this means

Regulatory status

as of registry sync 23 Oct 2026

RegionAuthorizationNumberDateStatus
United StatesGUDID listing Number00841436109406 UDI-DI Date22 Aug 2017ListedStatusListed GUDID: not in commercial distribution

Recalls

17 recalls · 8 ongoing · FDA

  • 8 recalls, same reason

    • Ongoing Z-1738-2026 FDA Class II initiated 2 Mar 2026
    • Ongoing Z-1736-2026 FDA Class II initiated 2 Mar 2026
    • Ongoing Z-1735-2026 FDA Class II initiated 2 Mar 2026
    • Ongoing Z-1737-2026 FDA Class II initiated 2 Mar 2026
    • Ongoing Z-1732-2026 FDA Class II initiated 2 Mar 2026
    • Ongoing Z-1731-2026 FDA Class II initiated 2 Mar 2026
    • Ongoing Z-1734-2026 FDA Class II initiated 2 Mar 2026
    • Ongoing Z-1733-2026 FDA Class II initiated 2 Mar 2026

    There was an error in inspection and programming of the eTRAX needle sensor for Aurora trackers. The result is a potential for the needle tip position to be incorrectly identified on the user interface.

  • 4 recalls, same reason

    • Terminated Z-0396-2022 FDA Class II initiated 8 Oct 2021
    • Terminated Z-0397-2022 FDA Class II initiated 8 Oct 2021
    • Terminated Z-0398-2022 FDA Class II initiated 8 Oct 2021
    • Terminated Z-0395-2022 FDA Class II initiated 8 Oct 2021

    There is potential that the VirtuTRAX device will not tighten onto the instrument to be used.

  • 5 recalls, same reason

    • Terminated Z-1955-2012 FDA Class II initiated 7 May 2012
    • Terminated Z-1952-2012 FDA Class II initiated 7 May 2012
    • Terminated Z-1953-2012 FDA Class II initiated 7 May 2012
    • Terminated Z-1954-2012 FDA Class II initiated 7 May 2012
    • Terminated Z-1956-2012 FDA Class II initiated 7 May 2012

    The general purpose electromagnetic sensor was incorrectly calibrated causing potential variability in the projected position of the needle path with the ultrasound device.

Coverage

1 jurisdiction

United States of America
  • Active
  • Expiring
  • Withdrawn
  • Listed
  • Not covered

United States — GUDID listing Listed

Specification

GUDID

Trade Name
omniTRAX Patient Tracker Starter Kit
Generic Name
Patient positioning sensor
Model / Ref / Catalog
H4913AT
Primary DI / UDI-DI
00841436109406
510(k) Number
FDA Product Code
IYO
GMDN Term
Patient positioning sensor
Device Class
Class II
Regulation Number
892.1560
GUDID distribution status
Not in Commercial Distribution
Size
Width — 7 Inch
Length — 1.95 Inch

Other devices from Civco Medical Instruments Co., Inc.

See all devices from Civco Medical Instruments Co., Inc. →

Properties

  • Prescription Use
  • Convenience Kit
  • Lot / Batch Number
  • Expiration Date
  • Manufacturing Date

Other properties (9)

  • Sterile: No
  • Single Use: No
  • Implantable: No
  • Contains Latex: No
  • Over-the-Counter: No
  • Combination Product: No
  • HCT/P: No
  • Premarket Exempt: No
  • Serial Number: No